Literature DB >> 133758

Transcutaneous measurement of blood flow velocity in the human aorta.

B A Angelsen, A O Brubakk.   

Abstract

A Doppler velocity meter for measuring blood flow velocity in the human aorta is described. Using pulsed ultrasound, this instrument allows the velocity to be measured at selected depths. The instrument has been tested in laboratory experiments, and appears to give accurate estimates of mean flow velocity for both steady and pulsatile flows. Flow velocities and estimates of stroke volume have been obtained from the ascending aorta in 18 patients. It is suggested that at present only relative values for flow and flow velocity can be measured. A method for obtaining absolute values for these parameters, based on scanning in the aortic arch, is proposed.

Entities:  

Mesh:

Year:  1976        PMID: 133758     DOI: 10.1093/cvr/10.3.368

Source DB:  PubMed          Journal:  Cardiovasc Res        ISSN: 0008-6363            Impact factor:   10.787


  11 in total

1.  Transcutaneous Doppler ultrasound measurement of superior mesenteric artery blood flow in man.

Authors:  M I Qamar; A E Read; R Skidmore; J M Evans; P N Wells
Journal:  Gut       Date:  1986-01       Impact factor: 23.059

2.  Effect of morphine on the human oesophagus.

Authors:  S N Sullivan
Journal:  Gut       Date:  1986-01       Impact factor: 23.059

3.  A time domain mean frequency estimation algorithm of two-dimensional real-time Doppler imaging system.

Authors:  N F Güler
Journal:  J Med Syst       Date:  1995-10       Impact factor: 4.460

4.  Determination of cardiac output by Doppler echocardiography.

Authors:  H Ihlen; J P Amlie; J Dale; K Forfang; S Nitter-Hauge; J E Otterstad; S Simonsen; E Myhre
Journal:  Br Heart J       Date:  1984-01

5.  Measurement of human fetal blood flow.

Authors:  J B Sauders; N Wright; K O Lewis
Journal:  Br Med J       Date:  1980-02-02

6.  Non-invasive estimation of pulmonary artery systolic pressure with Doppler ultrasound.

Authors:  L Hatle; B A Angelsen; A Tromsdal
Journal:  Br Heart J       Date:  1981-02

7.  Changes in left ventricular stroke volume measured by Doppler echocardiography.

Authors:  H Ihlen; E Myhre; J Pamlie; K Forfang; S Larsen
Journal:  Br Heart J       Date:  1985-10

8.  Clinical value of Doppler echocardiography in the assessment of adults with aortic stenosis.

Authors:  I A Simpson; A B Houston; C D Sheldon; I Hutton; T D Lawrie
Journal:  Br Heart J       Date:  1985-06

9.  VasoTracker, a Low-Cost and Open Source Pressure Myograph System for Vascular Physiology.

Authors:  Penelope F Lawton; Matthew D Lee; Christopher D Saunter; John M Girkin; John G McCarron; Calum Wilson
Journal:  Front Physiol       Date:  2019-02-21       Impact factor: 4.566

10.  Flow velocity quantification by exploiting the principles of the Doppler effect and magnetic particle imaging.

Authors:  Dennis Pantke; Florian Mueller; Sebastian Reinartz; Fabian Kiessling; Volkmar Schulz
Journal:  Sci Rep       Date:  2021-02-25       Impact factor: 4.379

View more