Combined doppler and phased-array echocardiographic estimation of cardiac output.

P A Magnin, J A Stewart, S Myers, O von Ramm, J A Kisslo.   

Abstract

The capability of a pulsed Doppler flowmeter combined with a phased-array imaging system to measure volume flow was tested in vitro and in patients undergoing cardiac catheterization. The Doppler-phased-array system (DPA) was used to determine vessel diameter and a superimposed cursor was used to locate the range and angle of the Doppler sample volume. DPA estimates of continuous flow through tubing in a water tank correlated strongly (r = 0.99) with measured flow corresponding to physiologic ranges from 3-12 l/min. For pulsatile flow in a water tank, a correlation of r = 0.86 with measured flow was obtained, whereas DPA estimates of cardiac outputs compared with Fick estimates in the 11 patients produced a correlation of r = 0.83. These data indicate that estimates of cardiac output are possible using the DPA approach.

Entities:  

Mesh:

Year:  1981        PMID: 7449060     DOI: 10.1161/01.cir.63.2.388

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  20 in total

Review 1.  Non-invasive methods of measuring cardiac output.

Authors:  G J Dobb; K D Donovan
Journal:  Intensive Care Med       Date:  1987       Impact factor: 17.440

2.  Ultrasonic flowmeter with implantable miniature sensors.

Authors:  T Nakamura; K Hayashi; Y Taenaka; M Umezu; T Nakatani; H Takano
Journal:  Med Biol Eng Comput       Date:  1986-05       Impact factor: 2.602

3.  Detection of exercise induced changes in left ventricular performance by Doppler echocardiography.

Authors:  P J Daley; K B Sagar; B D Collier; J Kalbfleisch; L S Wann
Journal:  Br Heart J       Date:  1987-11

4.  Effect of age and blood pressure on aortic size and stroke distance.

Authors:  B A Towfiq; J Weir; J M Rawles
Journal:  Br Heart J       Date:  1986-06

5.  Doppler-derived cardiac output in healthy newborn infants in relation to physiological patency of the ductus arteriosus.

Authors:  H Hirsimäki; P Kero; O Wanne; R Erkkola; Z Makoi
Journal:  Pediatr Cardiol       Date:  1988       Impact factor: 1.655

6.  Reproducibility of linear cardiac output measurement by Doppler ultrasound alone.

Authors:  F M McLennan; N E Haites; J D Mackenzie; M K Daniel; J M Rawles
Journal:  Br Heart J       Date:  1986-01

Review 7.  Cardiac output measurements. A review of current techniques and research.

Authors:  K C Ehlers; K C Mylrea; C K Waterson; J M Calkins
Journal:  Ann Biomed Eng       Date:  1986       Impact factor: 3.934

8.  Doppler echocardiographic measurement of cardiac output using the mitral orifice method.

Authors:  Y Zhang; S Nitter-Hauge; H Ihlen; E Myhre
Journal:  Br Heart J       Date:  1985-02

9.  The effect of epidural anaesthesia with 1% lidocaine on the pressor response to dynamic exercise in man.

Authors:  D B Friedman; J Brennum; F Sztuk; O B Hansen; P S Clifford; F W Bach; L Arendt-Nielsen; J H Mitchell; N H Secher
Journal:  J Physiol       Date:  1993-10       Impact factor: 5.182

10.  Quantitative Doppler-echocardiographic determination of regurgitant volume in patients with aortic insufficiency.

Authors:  Paul Schoenhagen; Ludwig Drude; Hermann H Klein; Mario J Garcia
Journal:  Open Cardiovasc Med J       Date:  2008-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.