Literature DB >> 6646070

A scanning system for chest radiography with regional exposure control: theoretical considerations.

D B Plewes.   

Abstract

Conventional chest radiography is limited by the presence of scattered radiation and the small useful exposure range of radiographic film. A computer-assisted scanning system to minimize these two effects is outlined. The system uses a small beam of radiation swept over the patient's chest in a raster pattern to expose a conventional film cassette, while a slit collimator scanning between the patient and the film serves to reject scattered photons. A microcomputer measures beam attenuation by the patient with a detector placed behind the film which in turn automatically adjusts the x-ray tube output to minimize excursions in film exposure as the beam scans. A formalism which relates the patient transmission and film exposure distribution is developed and a system transfer function is given. It is shown that such a system operates as a spatial filter which attenuates film contrast for structures of spatial frequency less than the inverse scanning beam width. By manipulating the software parameters of the feedback network, it is possible to alter this filter and produce radiographs with low spatial frequency enhancement, attenuation, or contrast inversion.

Entities:  

Mesh:

Year:  1983        PMID: 6646070     DOI: 10.1118/1.595327

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  6 in total

1.  Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.

Authors:  Xinming Liu; Chris C Shaw
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

2.  A digital imaging and communications in medicine (DICOM) print service for chest imaging.

Authors:  D M Tucker; C T Suitor; S J Shepard; D F Schomer
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

3.  Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.

Authors:  Xinming Liu; Chris C Shaw; Chao-Jen Lai; Tianpeng Wang
Journal:  Med Phys       Date:  2011-01       Impact factor: 4.071

4.  Experimental realization of fluence field modulated CT using digital beam attenuation.

Authors:  T P Szczykutowicz; C A Mistretta
Journal:  Phys Med Biol       Date:  2014-02-20       Impact factor: 3.609

5.  Role of equalisation mammography of dense breasts.

Authors:  D B Plewes; J M Sabol; I Soutar; A Chevrier; R Shumak
Journal:  Med Biol Eng Comput       Date:  1995-03       Impact factor: 2.602

6.  Scan equalization digital radiography (SEDR) implemented with an amorphous selenium flat-panel detector: initial experience.

Authors:  Xinming Liu; Chao-Jen Lai; Lingyun Chen; Tao Han; Yuncheng Zhong; Youtao Shen; Tianpeng Wang; Chris C Shaw
Journal:  Phys Med Biol       Date:  2009-11-04       Impact factor: 3.609

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.