Literature DB >> 6624871

Dynamics of cover test eye movements.

E Peli, G McCormack.   

Abstract

The dynamics of unilateral cover test eye movements, never before systematically investigated with an objective recording system, are shown to be more complex than textbook accounts of them. We administered the cover test to nine heterophoric subjects by means of electromechanical occluders. Eye movements were recorded using the infrared photoelectric technique. Saccadic and vergence movements of the fixating eye were observed in almost all records when the occluded eye was uncovered. These movements were found in esophores and exophores and in both large and small phoria cases. Such movements were previously described in other asymmetric vergence tasks and appear to obey Hering's law of equal innervation. Uncovering the dominant eye, in cases of clear dominancy, resulted in shorter latency and larger amplitude saccades than did uncovering the nondominant eye. These large saccades were frequently of unequal amplitude in each eye. Trained subjects appear to use dynamic overshoots to increase this saccadic inequality and thereby attain vergence during saccades. Movements after the application of a cover to one eye, while grossly similar to textbook descriptions of them, are found to contain small vergence drifts and refixation (correcting) saccades in the nonoccluded eye.

Mesh:

Year:  1983        PMID: 6624871     DOI: 10.1097/00006324-198308000-00010

Source DB:  PubMed          Journal:  Am J Optom Physiol Opt        ISSN: 0093-7002


  7 in total

1.  Capturing the Moment of Fusion Loss in Intermittent Exotropia.

Authors:  John R Economides; Daniel L Adams; Jonathan C Horton
Journal:  Ophthalmology       Date:  2017-01-09       Impact factor: 12.079

2.  Near heterophoria in early childhood.

Authors:  Erin Babinsky; Vidhyapriya Sreenivasan; T Rowan Candy
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-01-29       Impact factor: 4.799

3.  Binocular retinal image differences influence eye-position signals for perceived visual direction.

Authors:  Deepika Sridhar; Harold E Bedell
Journal:  Vision Res       Date:  2012-04-26       Impact factor: 1.886

4.  Variance components affecting the repeatability of the alternating cover test.

Authors:  Marius M Paulus; Andreas Straube; Thomas Eggert
Journal:  J Eye Mov Res       Date:  2019-08-28       Impact factor: 0.957

5.  Bilateral Occlusion Reduces the Ocular Deviation in Intermittent Exotropia.

Authors:  John R Economides; Daniel L Adams; Jonathan C Horton
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-01-04       Impact factor: 4.799

6.  Synchronization of a Removable Optical Element with an Eye Tracker: Test Case for Heterophoria Measurement.

Authors:  Liat Gantz; Avi Caspi
Journal:  Transl Vis Sci Technol       Date:  2020-06-29       Impact factor: 3.283

7.  An automated and objective cover test to measure heterophoria.

Authors:  Clara Mestre; Carles Otero; Fernando Díaz-Doutón; Josselin Gautier; Jaume Pujol
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.