Literature DB >> 33828743

Variance components affecting the repeatability of the alternating cover test.

Marius M Paulus1, Andreas Straube1, Thomas Eggert1.   

Abstract

In within-subject and within-examiner repeated measures designs, measures of heterophoria with the manual prism cover test achieve standard deviations between 0.5 and 0.8 deg. We addressed the question how this total noise is composed of variable errors related to the examiner (measurement noise), to the size of the heterophoria (heterophoria noise), and to the availability of sensory vergence cues (stimulus noise). We developed an automated alternating cover test (based on a combination of VOG and shutter glasses) which minimizes stimulus noise and has a defined measurement noise (sd=0.06 deg). In a within-subject design, 19 measures were taken within 1.5 min and multiple such blocks were repeated either across days or across 45 min. Blocks were separated by periods of binocular viewing. The standard deviation of the heterophoria across blocks from different days or from the same day (sd=0.33 deg) was 6 times larger than expected based on the standard deviation within the block. The results show that about 42% of the inter-block variance with the manual prism cover test was related to variability of the heterophoria and not to measurement noise or stimulus noise. The heterophoria noise across blocks was predominantly induced during the intermediate binocular viewing periods.

Entities:  

Keywords:  Heterophoria; cover test; eye movement; eye tracking; gaze; reliability; vergence

Year:  2019        PMID: 33828743      PMCID: PMC7880145          DOI: 10.16910/jemr.12.4.3

Source DB:  PubMed          Journal:  J Eye Mov Res        ISSN: 1995-8692            Impact factor:   0.957


  15 in total

1.  Comparison of alternate cover test reliability at near in non-strabismus between experienced and novice examiners.

Authors:  Patricia K Hrynchak; Christopher Herriot; Elizabeth L Irving
Journal:  Ophthalmic Physiol Opt       Date:  2010-05       Impact factor: 3.117

2.  G*Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences.

Authors:  Franz Faul; Edgar Erdfelder; Albert-Georg Lang; Axel Buchner
Journal:  Behav Res Methods       Date:  2007-05

3.  The effect of testing method on values obtained for phoria at 40 centimeters.

Authors:  M J HIRSCH; L B BING
Journal:  Am J Optom Arch Am Acad Optom       Date:  1948-09

4.  Quantification of heterophoria and phoria adaptation using an automated objective system compared to clinical methods.

Authors:  Sang J Han; Yi Guo; Bérangère Granger-Donetti; Vincent R Vicci; Tara L Alvarez
Journal:  Ophthalmic Physiol Opt       Date:  2009-08-13       Impact factor: 3.117

Review 5.  Reliability of and comparisons among methods of measuring dissociated phoria.

Authors:  T L Schroeder; B B Rainey; D A Goss; T P Grosvenor
Journal:  Optom Vis Sci       Date:  1996-06       Impact factor: 1.973

6.  Further properties of the human saccadic system: eye movements and correction saccades with and without visual fixation points.

Authors:  W Becker; A F Fuchs
Journal:  Vision Res       Date:  1969-10       Impact factor: 1.886

7.  A quantitative analysis of eye movements during the cover test--a preliminary report.

Authors:  N A Barnard; W D Thomson
Journal:  Ophthalmic Physiol Opt       Date:  1995-09       Impact factor: 3.117

8.  Dynamics of cover test eye movements.

Authors:  E Peli; G McCormack
Journal:  Am J Optom Physiol Opt       Date:  1983-08

9.  EyeSeeCam: an eye movement-driven head camera for the examination of natural visual exploration.

Authors:  Erich Schneider; Thomas Villgrattner; Johannes Vockeroth; Klaus Bartl; Stefan Kohlbecher; Stanislavs Bardins; Heinz Ulbrich; Thomas Brandt
Journal:  Ann N Y Acad Sci       Date:  2009-05       Impact factor: 5.691

10.  An automated and objective cover test to measure heterophoria.

Authors:  Clara Mestre; Carles Otero; Fernando Díaz-Doutón; Josselin Gautier; Jaume Pujol
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.