Literature DB >> 6611565

Improved interpretation of gated cardiac images by use of digital filters.

T R Miller, K J Goldman, D M Epstein, D R Biello, K S Sampathkumaran, B Kumar, B A Siegel.   

Abstract

The authors describe a digital filter that greatly enhances the quality of gated cardiac blood-pool images. Spatial filtering is accomplished with a minimum-mean-square-error (Wiener) filter incorporating measured camera blur and Poisson noise statistics. A low-pass temporal filter is then applied to each pixel, with the cutoff frequency determined from measurements of frequency spectra in 20 patients. This filter was evaluated in routine clinical use for nearly one year and found to significantly improve chamber definition, delineate wall motion abnormalities better, and reduce noise. To quantitatively assess the effect of the filter on image interpretation, four experienced observers evaluated wall motion in a series of mathematically simulated left ventricular images. ROC analysis revealed that accuracy in assessing wall motion was significantly greater with the filtered images.

Entities:  

Mesh:

Year:  1984        PMID: 6611565     DOI: 10.1148/radiology.152.3.6611565

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Improved positron emission tomography quantification by Fourier-based restoration filtering.

Authors:  J M Links; J P Leal; H W Mueller-Gaertner; H N Wagner
Journal:  Eur J Nucl Med       Date:  1992

2.  Equilibrium radionuclide angiocardiography.

Authors:  James R Corbett; Olakunle O Akinboboye; Stephen L Bacharach; Jeffrey S Borer; Elias H Botvinick; E Gordon DePuey; Edward P Ficaro; Christopher L Hansen; Milena J Henzlova; Serge Van Kriekinge
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

3.  Interactive reconstruction in single-photon tomography.

Authors:  T R Miller; J W Wallis; A D Wilson
Journal:  Eur J Nucl Med       Date:  1989

4.  Clinical validation of fully-automated contour detection for gated radionuclide ventriculography with a slant-hole collimator.

Authors:  M Hosoba; H Wani; M Hiroe; K Kusakabe
Journal:  Eur J Nucl Med       Date:  1986

5.  An efficient and cost effective nuclear medicine image network.

Authors:  K S Sampathkumaran; T R Miller
Journal:  Eur J Nucl Med       Date:  1987

6.  Use of a nonstationary temporal Wiener filter in nuclear medicine.

Authors:  M A King; T R Miller
Journal:  Eur J Nucl Med       Date:  1985

7.  Computation of left ventricular volume curves from gated blood pool studies without explicit use of edge detection algorithms: concise communication.

Authors:  U Raff; P F Vargas; A L Scherzinger; L H Rodriguez; B M Groves
Journal:  Int J Card Imaging       Date:  1995-03
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.