Literature DB >> 7730683

Computation of left ventricular volume curves from gated blood pool studies without explicit use of edge detection algorithms: concise communication.

U Raff1, P F Vargas, A L Scherzinger, L H Rodriguez, B M Groves.   

Abstract

A new technique has been developed to compute left ventricular (LV) time activity curves from gated blood pool (GBP) studies without the use of manual, semiautomated or fully automated edge detection algorithms. The method utilizes the correlation of entropy calculated from the counts of a fixed region of interest covering the left ventricle during a cardiac cycle to compute the LV volume curve for a new patient. The new LV volume curve is obtained through interpolation of those volume curves of a data base which are associated with the closest variations in normalized entropy to the new one. The computed LV time activity curves agree with those obtained from manual or fully automated outlines of the left ventricle within 9 percent for the selected set of 67 patients demonstrating the potential of the method. The accuracy of calculated LV volume curves can be improved theoretically to any degree by increasing the number of cases in the data base of known statistical feature vectors associated with the LV images and LV volume curves. The new method for computation of LV curves is very efficient and robust when compared to traditional techniques.

Entities:  

Mesh:

Year:  1995        PMID: 7730683     DOI: 10.1007/bf01148949

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  11 in total

1.  Improved interpretation of gated cardiac images by use of digital filters.

Authors:  T R Miller; K J Goldman; D M Epstein; D R Biello; K S Sampathkumaran; B Kumar; B A Siegel
Journal:  Radiology       Date:  1984-09       Impact factor: 11.105

2.  A Wiener filter for nuclear medicine images.

Authors:  M A King; P W Doherty; R B Schwinger; B C Penney
Journal:  Med Phys       Date:  1983 Nov-Dec       Impact factor: 4.071

3.  Optimum fourier filtering of cardiac data: a minimum-error method: concise communication.

Authors:  S L Bacharach; M V Green; D Vitale; G White; M A Douglas; R O Bonow; S M Larson
Journal:  J Nucl Med       Date:  1983-12       Impact factor: 10.057

4.  Measurement of absolute left ventricular volume from gated blood pool studies.

Authors:  J M Links; L C Becker; J G Shindledecker; P Guzman; R D Burow; E L Nickoloff; P O Alderson; H N Wagner
Journal:  Circulation       Date:  1982-01       Impact factor: 29.690

5.  Quantitative analysis of left ventricular function from equilibrium gated blood pool scintigrams: an overview of computer methods.

Authors:  J H Reiber
Journal:  Eur J Nucl Med       Date:  1985

6.  Radionuclide measurement of left ventricular volume: comparison of geometric and counts-based methods.

Authors:  B M Massie; B L Kramer; E W Gertz; S G Henderson
Journal:  Circulation       Date:  1982-04       Impact factor: 29.690

7.  Nongeometric determination of left ventricular volumes from equilibrium blood pool scans.

Authors:  G J Dehmer; S E Lewis; L D Hillis; D Twieg; M Falkoff; R W Parkey; J T Willerson
Journal:  Am J Cardiol       Date:  1980-02       Impact factor: 2.778

8.  Methods for detection of left ventricular edges.

Authors:  W Chang; R E Henkin; D J Hale; D Hall
Journal:  Semin Nucl Med       Date:  1980-01       Impact factor: 4.446

9.  Left ventricular volumes by gated equilibrium radionuclide angiography: a new method.

Authors:  R Slutsky; J Karliner; D Ricci; R Kaiser; M Pfisterer; D Gordon; K Peterson; W Ashburn
Journal:  Circulation       Date:  1979-09       Impact factor: 29.690

10.  Repeatability of estimates of left-ventricular volume from blood-pool counts: concise communication.

Authors:  R J Burns; M N Druck; D S Woodward; S Houle; P R McLaughlin
Journal:  J Nucl Med       Date:  1983-09       Impact factor: 10.057

View more
  1 in total

1.  Automated determination of left ventricular volume curves from bi-plane digital angiography without explicit use of edge detection algorithms.

Authors:  U Raff; P F Vargas; B M Groves
Journal:  Int J Card Imaging       Date:  1996-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.