Pacemaker contact sensitivity.

M S Peters, A L Schroeter, H M van Hale, J C Broadbent.   

Abstract

In a patient who had 4 cardiac pacemakers implanted and removed, pruritus, redness, and swelling of the skin overlying the pacemaker developed at intervals of 6 weeks to 17 months after insertion. Patch testing showed a 2+ reaction to titanium. The positive result of this test, the titanium case of the generator, and the history of multiple local reactions around the generator site pointed toward contact sensitivity to the pacemaker. Although a review of the literature indicates that this problem is rare, it is of extreme importance to the patient with pacemaker contact dermatitis.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6499423     DOI: 10.1111/j.1600-0536.1984.tb00986.x

Source DB:  PubMed          Journal:  Contact Dermatitis        ISSN: 0105-1873            Impact factor:   6.600


  12 in total

1.  Long-term results of a cardiovascular implantable electronic device wrapped with an expanded polytetrafluoroethylene sheet.

Authors:  Bun Yashiro; Morio Shoda; Yasuko Tomizawa; Tetsuyuki Manaka; Nobuhisa Hagiwara
Journal:  J Artif Organs       Date:  2012-02-25       Impact factor: 1.731

2.  Cardiac rhythm device contact dermatitis.

Authors:  Jaskaran Kang; Christopher S Simpson; Debra Campbell; Rozita Borici-Mazi; Damian P Redfearn; Kevin A Michael; Hoshiar Abdollah; Adrian Baranchuk
Journal:  Ann Noninvasive Electrocardiol       Date:  2012-08-13       Impact factor: 1.468

Review 3.  [Hypersensitivity reactions to implantable cardiac pacemakers and defibrillators].

Authors:  B Kreft
Journal:  Hautarzt       Date:  2016-05       Impact factor: 0.751

4.  Corrosion of stainless steel sternal wire after long-term implantation.

Authors:  Yasuko Tomizawa; Takao Hanawa; Daisuke Kuroda; Hiroshi Nishida; Masahiro Endo
Journal:  J Artif Organs       Date:  2006       Impact factor: 1.731

5.  [Pathophysiology of posttraumatic osteitis].

Authors:  T Kälicke; F Kutscha-Lissberg; T M Frangen; G Muhr; S Arens
Journal:  Orthopade       Date:  2004-04       Impact factor: 1.087

6.  Prevention of pacemaker-associated contact dermatitis by polytetrafluoroethylene sheet and conduit coating of the pacemaker system.

Authors:  Takahiro Taguchi; Satoru Maeba; Taijiro Sueda
Journal:  J Artif Organs       Date:  2014-06-05       Impact factor: 1.731

7.  Pacemaker component allergy: case report and review of the literature.

Authors:  David L Hayes; Kathy Loesl
Journal:  J Interv Card Electrophysiol       Date:  2002-07       Impact factor: 1.900

Review 8.  Allergic Reactions to Dental Materials-A Systematic Review.

Authors:  Meena Syed; Radhika Chopra; Vinod Sachdev
Journal:  J Clin Diagn Res       Date:  2015-10-01

9.  A review of the biologic effects of spine implant debris: Fact from fiction.

Authors:  Nadim James Hallab
Journal:  SAS J       Date:  2009-12-01

10.  Formation of potential titanium antigens based on protein binding to titanium dioxide nanoparticles.

Authors:  Carmen Irina Vamanu; Paul Johan Høl; Zouhir Ekeland Allouni; Said Elsayed; Nils Roar Gjerdet
Journal:  Int J Nanomedicine       Date:  2008
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.