Long-term results of a cardiovascular implantable electronic device wrapped with an expanded polytetrafluoroethylene sheet.

Bun Yashiro1, Morio Shoda, Yasuko Tomizawa, Tetsuyuki Manaka, Nobuhisa Hagiwara.   

Abstract

The use of an expanded polytetrafluoroethylene (ePTFE) sheet wrapping device for patients with pacemaker contact dermatitis is still controversial. This study aimed to retrospectively investigate the occurrence rate of allergies and other complications after implantation of a cardiovascular implantable electronic device (CIED) wrapped with an ePTFE sheet. A total of 4,497 procedures of CIED implantation were performed at our institution between January 1993 and April 2010. Among 19 patients who underwent implantation of an electronic cardiac device wrapped with an ePTFE sheet, device implantation was performed in 11 patients for secondary prevention of device contact sensitivity, in 7 patients for primary prevention of device contact sensitivity, and in 1 patient for avoiding over-sensing of myopotentials. During follow-up periods (mean 46 ± 34 months), there were no allergic or inflammatory reactions to components of the device or ePTFE itself. Among 11 patients with a device wrapped with an ePTFE sheet for secondary prevention, 5 patients completed device replacement due to battery depletion and 3 patients had infections from the device. Wrapping implantable devices with an ePTFE sheet is an effective way of preventing device sensitivity in patients who require CIED therapy. However, the risk of infection from the device should be taken into consideration.

Entities:  

Mesh:

Substances:

Year:  2012        PMID: 22362192     DOI: 10.1007/s10047-012-0634-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  20 in total

1.  Pacemaker dermatitis from titanium.

Authors:  R Yamauchi; A Morita; T Tsuji
Journal:  Contact Dermatitis       Date:  2000-01       Impact factor: 6.600

2.  Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure.

Authors:  Michael R Bristow; Leslie A Saxon; John Boehmer; Steven Krueger; David A Kass; Teresa De Marco; Peter Carson; Lorenzo DiCarlo; David DeMets; Bill G White; Dale W DeVries; Arthur M Feldman
Journal:  N Engl J Med       Date:  2004-05-20       Impact factor: 91.245

3.  Corrosion of pure titanium sternal wire.

Authors:  Yasuko Tomizawa; Takao Hanawa
Journal:  Ann Thorac Surg       Date:  2007-09       Impact factor: 4.330

4.  Granulomatous dermatitis after implantation of a titanium-containing pacemaker.

Authors:  R Viraben; S Boulinguez; C Alba
Journal:  Contact Dermatitis       Date:  1995-12       Impact factor: 6.600

5.  Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction.

Authors:  Arthur J Moss; Wojciech Zareba; W Jackson Hall; Helmut Klein; David J Wilber; David S Cannom; James P Daubert; Steven L Higgins; Mary W Brown; Mark L Andrews
Journal:  N Engl J Med       Date:  2002-03-19       Impact factor: 91.245

6.  Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure.

Authors:  Gust H Bardy; Kerry L Lee; Daniel B Mark; Jeanne E Poole; Douglas L Packer; Robin Boineau; Michael Domanski; Charles Troutman; Jill Anderson; George Johnson; Steven E McNulty; Nancy Clapp-Channing; Linda D Davidson-Ray; Elizabeth S Fraulo; Daniel P Fishbein; Richard M Luceri; John H Ip
Journal:  N Engl J Med       Date:  2005-01-20       Impact factor: 91.245

7.  Pacemaker contact sensitivity.

Authors:  M S Peters; A L Schroeter; H M van Hale; J C Broadbent
Journal:  Contact Dermatitis       Date:  1984-10       Impact factor: 6.600

8.  Pacemaker dermatitis.

Authors:  R Brun; N Hunziker
Journal:  Contact Dermatitis       Date:  1980-04       Impact factor: 6.600

9.  Allergy to pacemaker silicone compounds: recognition and surgical management.

Authors:  Mihaela L Oprea; Heike Schnöring; Jörg S Sachweh; Hagen Ott; Julia Biertz; Jaime F Vazquez-Jimenez
Journal:  Ann Thorac Surg       Date:  2009-04       Impact factor: 4.330

10.  Update on cardiovascular implantable electronic device infections and their management: a scientific statement from the American Heart Association.

Authors:  Larry M Baddour; Andrew E Epstein; Christopher C Erickson; Bradley P Knight; Matthew E Levison; Peter B Lockhart; Frederick A Masoudi; Eric J Okum; Walter R Wilson; Lee B Beerman; Ann F Bolger; N A Mark Estes; Michael Gewitz; Jane W Newburger; Eleanor B Schron; Kathryn A Taubert
Journal:  Circulation       Date:  2010-01-04       Impact factor: 29.690

View more
  6 in total

Review 1.  Systemic contact dermatitis and allergy to biomedical devices.

Authors:  Marcella Aquino; Tania Mucci
Journal:  Curr Allergy Asthma Rep       Date:  2013-10       Impact factor: 4.806

2.  Photoactive fluoropolymer surfaces that release sensitizer drug molecules.

Authors:  Goutam Ghosh; Mihaela Minnis; Ashwini A Ghogare; Inna Abramova; Keith A Cengel; Theresa M Busch; Alexander Greer
Journal:  J Phys Chem B       Date:  2015-02-26       Impact factor: 2.991

Review 3.  Journal of Artificial Organs 2012: the year in review.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2013-02-28       Impact factor: 1.731

Review 4.  Biomaterial applications in cardiovascular tissue repair and regeneration.

Authors:  Mai T Lam; Joseph C Wu
Journal:  Expert Rev Cardiovasc Ther       Date:  2012-08

5.  Prevention of pacemaker-associated contact dermatitis by polytetrafluoroethylene sheet and conduit coating of the pacemaker system.

Authors:  Takahiro Taguchi; Satoru Maeba; Taijiro Sueda
Journal:  J Artif Organs       Date:  2014-06-05       Impact factor: 1.731

Review 6.  Biomaterials in cardiovascular research: applications and clinical implications.

Authors:  Saravana Kumar Jaganathan; Eko Supriyanto; Selvakumar Murugesan; Arunpandian Balaji; Manjeesh Kumar Asokan
Journal:  Biomed Res Int       Date:  2014-05-08       Impact factor: 3.411

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.