Literature DB >> 6499155

A new method to calculate aortic valve area without left heart catheterization.

D C Warth, W J Stewart, P C Block, A E Weyman.   

Abstract

Assessment of the severity of aortic stenosis remains a commonly encountered clinical problem. Noninvasive evaluation has to date not proven sufficiently accurate in most cases to permit clinical decision making in the individual patient. Therefore, cardiac catheterization and measurement of the valve area with use of the Gorlin equation remains the standard approach in patients with suspected aortic stenosis. Doppler ultrasound allows direct measurement of blood velocity in cardiac chambers. This technique was used to study 16 patients with suspected aortic stenosis after cardiac catheterization. Aortic valve area (AVA) was calculated with the equation AVA = CO/(SEP X mean velocity), where CO is cardiac output measured by thermodilution and SEP is the systolic ejection period derived from the Doppler tracings. The resulting value was compared with valve area calculated from cardiac catheterization data and an excellent correlation was noted (r = .99). This study demonstrates that Doppler ultrasound can be used to accurately measure aortic valve area without the need for left heart catheterization.

Entities:  

Mesh:

Year:  1984        PMID: 6499155     DOI: 10.1161/01.cir.70.6.978

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  7 in total

1.  A new non-invasive estimation of the stenotic aortic valve area by pulsed Doppler mapping.

Authors:  C Veyrat; C Gourtchiglouian; P Dumora; G Abitbol; D Sainte Beuve; D Kalmanson
Journal:  Br Heart J       Date:  1987-01

Review 2.  Quantitative applications of Doppler cardiography in congenital heart disease.

Authors:  S D Colan
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

3.  A hybrid approach for quantification of aortic valve stenosis using cardiac magnetic resonance imaging and echocardiography: comparison to right heart catheterization and standard echocardiography.

Authors:  D Haghi; T Suselbeck; S Fluechter; G Kalmar; M Schroder; J J Kaden; T Poerner; M Borggrefe; T Papavassiliu
Journal:  Clin Res Cardiol       Date:  2006-02-13       Impact factor: 5.460

4.  Comparison of Doppler echocardiographic methods with heart catheterisation in assessing aortic valve area in 100 patients with aortic stenosis.

Authors:  J L Fischer; T Haberer; D Dickson; L Henselmann
Journal:  Br Heart J       Date:  1995-03

5.  [Percutaneous transfemoral valvuloplasty in patients with calcified aortic stenosis and significantly increased surgical risk: clinical course and value of Doppler sonography in assessment of therapeutic success].

Authors:  H Kücherer; H Katus; R Dietz; B Rauch; W Kübler
Journal:  Klin Wochenschr       Date:  1988-07-01

6.  A hybrid approach for quantifying aortic valve stenosis using impedance cardiography and echocardiography.

Authors:  Yunis Daralammouri; Khubaib Ayoub; Najwan Badrieh; Bernward Lauer
Journal:  BMC Cardiovasc Disord       Date:  2016-01-22       Impact factor: 2.298

7.  Cardiac output measurements via echocardiography versus thermodilution: A systematic review and meta-analysis.

Authors:  Yun Zhang; Yan Wang; Jing Shi; Zhiqiang Hua; Jinyu Xu
Journal:  PLoS One       Date:  2019-10-03       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.