Literature DB >> 3210654

[Percutaneous transfemoral valvuloplasty in patients with calcified aortic stenosis and significantly increased surgical risk: clinical course and value of Doppler sonography in assessment of therapeutic success].

H Kücherer1, H Katus, R Dietz, B Rauch, W Kübler.   

Abstract

Percutaneous transluminal valvuloplasty (PTV) was performed in 24 patients (aged 67-86 years, mean: 76 +/- 5.7 years) with calcific aortic stenosis and high operative risk. The gradient between maximal left ventricular and aortic pressures (peak-to-peak gradient, PPPG) could be reduced by 52% from 73 +/- 21 to 34 +/- 12 mmHg (p less than 0.001). Peak pressure gradient (PPG), as assessed by continuous wave Doppler, could be reduced from 80 +/- 28 to 58 +/- 21 mmHg (p less than 0.001). Aortic valve area (AVA) as determined by Doppler and two dimensional echocardiography increased significantly from 0.39 +/- 0.14 to 0.61 +/- 0.3 cm2 (p less than 0.05). Clinical symptoms were found to be improved in 5 of 8 patients with impaired ejection fraction and in 11 of 16 patients with normal ejection fraction during the first week after PTV. Complications due to the procedure were surgical revision of femoral artery puncture site in one patient and hemodynamic relevant pericardial effusion in another patient. Transmitral early (E) and late (L) diastolic filling integrals were measured by pulsed Doppler: the ratio E/L decreased significantly after PTV from 0.9 +/- 0.5 to 0.63 +/- 0.31 (p less than 0.03) indicating further reduction of left ventricular early diastolic filling. Ejection fraction, stroke volume and cardiac output did not significantly change immediately after PTV.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1988        PMID: 3210654     DOI: 10.1007/bf01720831

Source DB:  PubMed          Journal:  Klin Wochenschr        ISSN: 0023-2173


  26 in total

1.  Assessment of left ventricular diastolic function: comparison of Doppler echocardiography and gated blood pool scintigraphy.

Authors:  B J Friedman; N Drinkovic; H Miles; W J Shih; A Mazzoleni; A N DeMaria
Journal:  J Am Coll Cardiol       Date:  1986-12       Impact factor: 24.094

2.  Systematic correlation of continuous-wave Doppler and hemodynamic measurements in patients with aortic stenosis.

Authors:  M D Smith; P L Dawson; J L Elion; T Wisenbaugh; O L Kwan; S Handshoe; A N DeMaria
Journal:  Am Heart J       Date:  1986-02       Impact factor: 4.749

3.  Determination of parameters of left ventricular diastolic filling with pulsed Doppler echocardiography: comparison with cineangiography.

Authors:  R Rokey; L C Kuo; W A Zoghbi; M C Limacher; M A Quinones
Journal:  Circulation       Date:  1985-03       Impact factor: 29.690

4.  Percutaneous balloon aortic valvuloplasty: results in 23 patients.

Authors:  Z Lababidi; J R Wu; J T Walls
Journal:  Am J Cardiol       Date:  1984-01-01       Impact factor: 2.778

5.  [Percutaneous bursting of the pulmonary valve].

Authors:  W D Bussmann; H Sievert; N Reifart
Journal:  Dtsch Med Wochenschr       Date:  1984-07-13       Impact factor: 0.628

6.  Percutaneous balloon valvuloplasty: a new method for treating congenital pulmonary-valve stenosis.

Authors:  J S Kan; R I White; S E Mitchell; T J Gardner
Journal:  N Engl J Med       Date:  1982-08-26       Impact factor: 91.245

7.  Transmitral blood flow reflecting diastolic behavior of the left ventricle in health and disease--a study by pulsed Doppler technique.

Authors:  A Kitabatake; M Inoue; M Asao; J Tanouchi; T Masuyama; H Abe; H Morita; S Senda; H Matsuo
Journal:  Jpn Circ J       Date:  1982-01

8.  Postmortem and intraoperative balloon valvuloplasty of calcific aortic stenosis in elderly patients: mechanisms of successful dilation.

Authors:  R D Safian; V S Mandell; R E Thurer; G M Hutchins; S J Schnitt; W Grossman; R G McKay
Journal:  J Am Coll Cardiol       Date:  1987-03       Impact factor: 24.094

Review 9.  Afterload mismatch in aortic and mitral valve disease: implications for surgical therapy.

Authors:  J Ross
Journal:  J Am Coll Cardiol       Date:  1985-04       Impact factor: 24.094

10.  A new method to calculate aortic valve area without left heart catheterization.

Authors:  D C Warth; W J Stewart; P C Block; A E Weyman
Journal:  Circulation       Date:  1984-12       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.