Literature DB >> 3801258

A new non-invasive estimation of the stenotic aortic valve area by pulsed Doppler mapping.

C Veyrat, C Gourtchiglouian, P Dumora, G Abitbol, D Sainte Beuve, D Kalmanson.   

Abstract

A new pulsed Doppler mapping technique has been used to measure the severity of aortic valve stenosis. The Doppler examination was performed at the site of the aortic orifice in the parasternal short axis echocardiographic view and the method was based on the detection of the area of systolic flow through the stenotic orifice. This area was derived by planimetry and the measurements obtained by the Doppler method were compared with the aortic valve area calculated at catheterisation according to the Gorlin formula. The method was applicable in 41 of the 44 patients studied. The Doppler data were consistent with the haemodynamic measurements even in patients with decreased cardiac index. It is concluded that this new application of the flow mapping procedure is reliable and is easily applied to adult patients with a wide range of clinical conditions.

Entities:  

Mesh:

Year:  1987        PMID: 3801258      PMCID: PMC1277145          DOI: 10.1136/hrt.57.1.44

Source DB:  PubMed          Journal:  Br Heart J        ISSN: 0007-0769


  18 in total

1.  Ejection time in aortic stenosis and mitral stenosis. Comparison between the direct and indirect arterial tracings with special reference to preand postoperative findings.

Authors:  A BENCHIMOL; E G DIMOND; Y SHEN
Journal:  Am J Cardiol       Date:  1960-06       Impact factor: 2.778

2.  [Qualitative and quantitative evaluation of aortic and mitral insufficiencies. Comparative study].

Authors:  J Carrillo Kabana; J Calderón Montero; J López Sendón; A Fuertes Garcia; J Pey Illera
Journal:  Rev Esp Cardiol       Date:  1976 May-Jun       Impact factor: 4.753

3.  Physical characteristics and mathematical modelling of the pulsed ultrasonic flowmeter.

Authors:  J E Jorgensen; D N Campau; D W Baker
Journal:  Med Biol Eng       Date:  1973-07

4.  Evaluation of pulmonary and systemic blood flow by 2-dimensional Doppler echocardiography using fast Fourier transform spectral analysis.

Authors:  S J Goldberg; D J Sahn; H D Allen; L M Valdes-Cruz; H Hoenecke; Y Carnahan
Journal:  Am J Cardiol       Date:  1982-12       Impact factor: 2.778

5.  Evaluation of tricuspid regurgitation by pulsed Doppler and two-dimensional echocardiography.

Authors:  K Miyatake; M Okamoto; N Kinoshita; M Ohta; T Kozuka; H Sakakibara; Y Nimura
Journal:  Circulation       Date:  1982-10       Impact factor: 29.690

6.  An ultrasound system for combined cardiac imaging and Doppler blood flow measurement in man.

Authors:  J M Griffith; W L Henry
Journal:  Circulation       Date:  1978-05       Impact factor: 29.690

7.  Angioscan: a spectrum analyser for use with ultrasonic Doppler velocimeters.

Authors:  P C Macpherson; S J Meldrum; D S Tunstall-Pedoe
Journal:  J Med Eng Technol       Date:  1981-03

8.  Non-invasive assessment of aortic stenosis by Doppler ultrasound.

Authors:  L Hatle; B A Angelsen; A Tromsdal
Journal:  Br Heart J       Date:  1980-03

9.  Value and limitations of cross-sectional echocardiography of the aortic valve in the diagnosis and quantification of valvular aortic stenosis.

Authors:  A N DeMaria; W Bommer; J Joye; G Lee; J Bouteller; D T Mason
Journal:  Circulation       Date:  1980-08       Impact factor: 29.690

10.  Cross-sectional echocardiography in assessing the severity of valvular aortic stenosis.

Authors:  A E Weyman; H Feigebaum; J C Dillon; S Chang
Journal:  Circulation       Date:  1975-11       Impact factor: 29.690

View more
  4 in total

1.  Planimetry of aortic valve area using multiplane transoesophageal echocardiography is not a reliable method for assessing severity of aortic stenosis.

Authors:  Y Bernard; N Meneveau; A Vuillemenot; D Magnin; T Anguenot; F Schiele; J P Bassand
Journal:  Heart       Date:  1997-07       Impact factor: 5.994

2.  Direction, site of origin and duration of jets: implications in the color Doppler assessment of valvar lesions. With emphasis on pure and combined mitral and bicuspid aortic lesions.

Authors:  C Veyrat; D Kalmanson
Journal:  Int J Card Imaging       Date:  1993-09

3.  Assessment of the orifice diameter by a multigated pulsed Doppler system in children with congenital semilunar valve stenosis.

Authors:  S de Knecht; J C Hopman; O Daniëls; G B Stoelinga; R S Reneman; A P Hoeks
Journal:  Br Heart J       Date:  1989-07

4.  Comparison of Doppler echocardiographic methods with heart catheterisation in assessing aortic valve area in 100 patients with aortic stenosis.

Authors:  J L Fischer; T Haberer; D Dickson; L Henselmann
Journal:  Br Heart J       Date:  1995-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.