Increased corneal thickness simulating elevated intraocular pressure.

M Johnson, M A Kass, R A Moses, W J Grodzki.   

Abstract

A 17-year-old girl had intraocular pressure readings of 30 to 40 mm Hg in both eyes, with normal visual fields and optic nerve heads. Medical treatment was unsuccessful in lowering the IOP measurements substantially. The central corneal thickness was 0.90 mm in each eye in the absence of corneal edema. Cannulation of the left anterior chamber revealed an IOP of 11 mm Hg, while the Perkins' and Schiŏtz' tonometers gave readings of 35 and 34 mm Hg, respectively. Previously, elevated tonometry readings had been obtained by Goldmann's, Perkins', Schiŏtz', MacKay and Marg's, pneumatic tonometer and air puff tonometer. This suggested that measurement of central corneal thickness be performed in cases in which IOP recordings do not correspond to other clinical findings.

Entities:  

Mesh:

Year:  1978        PMID: 646694     DOI: 10.1001/archopht.1978.03910050360012

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  30 in total

1.  Correlation between central corneal thickness, applanation tonometry, and direct intracameral IOP readings.

Authors:  N Feltgen; D Leifert; J Funk
Journal:  Br J Ophthalmol       Date:  2001-01       Impact factor: 4.638

2.  Measurement of intraocular pressure after epikeratophakia.

Authors:  M M Wright; A L Grajewski
Journal:  Br J Ophthalmol       Date:  1997-06       Impact factor: 4.638

3.  Intraobserver and interobserver reproducibility in the evaluation of ultrasonic pachymetry measurements of central corneal thickness.

Authors:  S Miglior; E Albe; M Guareschi; G Mandelli; S Gomarasca; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2004-02       Impact factor: 4.638

Review 4.  [Glaucoma diagnostics and corneal thickness].

Authors:  J von Eicken; M Kohlhaas; H Höh
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

Review 5.  [The risk of glaucoma and corneal thickness].

Authors:  A G Böhm
Journal:  Ophthalmologe       Date:  2005-09       Impact factor: 1.059

6.  Central corneal thickness and progression of the visual field and optic disc in glaucoma.

Authors:  B C Chauhan; D M Hutchison; R P LeBlanc; P H Artes; M T Nicolela
Journal:  Br J Ophthalmol       Date:  2005-08       Impact factor: 4.638

7.  Effects of corneal thickness on intraocular pressure measured with three different tonometers.

Authors:  Hiroki Murase; Akira Sawada; Kiyofumi Mochizuki; Tetsuya Yamamoto
Journal:  Jpn J Ophthalmol       Date:  2009-01-30       Impact factor: 2.447

8.  Circadian variations in central corneal thickness and intraocular pressure in patients with glaucoma.

Authors:  P Fogagnolo; L Rossetti; F Mazzolani; N Orzalesi
Journal:  Br J Ophthalmol       Date:  2006-01       Impact factor: 4.638

9.  Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study.

Authors:  Mona Pache; Sonja Wilmsmeyer; Sonja Lautebach; Jens Funk
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-03-09       Impact factor: 3.117

10.  Central corneal thickness and Diaton transpalpebral tonometry.

Authors:  Mustafa Ilker Toker; Ayse Vural; Haydar Erdogan; Aysen Topalkara; Mustafa Kemal Arici
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2008-02-20       Impact factor: 3.117

View more