Abstract

Deadtime performance of scintillation cameras is sensitive to such factors as scatter fraction and analyzer window width. Data from manufacturers and previous investigators do not predict counting-rate losses under clinical conditions. Scintillation cameras used with Tc-99m for quantitative nuclear cardiology should be evaluated for deadtime performance by the two-source method using a scatter phantom designed to simulate the spectrum from Tc-99m in the heart. Under these conditions, scintillation cameras were found to follow the paralyzable model; accurate estimates could be obtained for data losses and maximum useful counting rates in a clinical setting. A survey of 39 contemporary scintillation cameras yielded a range of paralyzing deadtime values of 4.3 to 10 musec, with a 20% window centered on the Tc-99m photopeak. For an average deadtime of 6 musec, counting rates should be maintained below 36,000 cps to avoid undue data losses in excess of 25%.

Entities:  

Mesh:

Year:  1978        PMID: 641578

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  10 in total

1.  Estimation of attenuation maps from scatter and photopeak window single photon-emission computed tomographic images of technetium 99m-labeled sestamibi.

Authors:  T S Pan; M A King; D S Luo; S T Dahlberg; B J Villegas
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

2.  A new method for quantification of image distortion due to pile-up in scintillation cameras.

Authors:  C Ceberg; I Larsson; S E Strand
Journal:  Eur J Nucl Med       Date:  1991

3.  A method of simultaneous dual-radionuclide cardiac imaging with technetium 99m and thallium 201. I: Analysis of interradionuclide crossover and validation in phantoms.

Authors:  H Weinstein; M A King; C P Reinhardt; B A McSherry; J A Leppo
Journal:  J Nucl Cardiol       Date:  1994 Jan-Feb       Impact factor: 5.952

4.  Determination of pulmonary mean transit time and cardiac output using a one-dimensional model.

Authors:  C Le Sech; A Capderou
Journal:  Bull Math Biol       Date:  1996-11       Impact factor: 1.758

Review 5.  First-pass radionuclide angiocardiography with single-crystal gamma cameras.

Authors:  K Nichols; E G DePuey; A Rozanski
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

6.  Characterization of the count rate performance of modern gamma cameras.

Authors:  M Silosky; V Johnson; C Beasley; S Cheenu Kappadath
Journal:  Med Phys       Date:  2013-03       Impact factor: 4.071

7.  Determination of right ventricular ejection fraction utilising a radionuclide washout technique.

Authors:  A van Aswegen; C P Herbst; A C Otto; M G Lötter; P H Kleynhans; P C Minnaar
Journal:  Eur J Nucl Med       Date:  1983

8.  Correction for deadtime losses in a gamma camera/data analysis system.

Authors:  K Cranley; R Millar; T K Bell
Journal:  Eur J Nucl Med       Date:  1980-08

9.  Deadtime effects in quantification of 177Lu activity for radionuclide therapy.

Authors:  Carlos F Uribe; Pedro L Esquinas; Marjorie Gonzalez; Wei Zhao; Jesse Tanguay; Anna Celler
Journal:  EJNMMI Phys       Date:  2018-01-11

10.  Image-based SPECT calibration based on the evaluation of the Fraction of Activity in the Field of View.

Authors:  Adrien Halty; Jean-Noël Badel; Olga Kochebina; David Sarrut
Journal:  EJNMMI Phys       Date:  2018-05-16
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.