Literature DB >> 9138841

First-pass radionuclide angiocardiography with single-crystal gamma cameras.

K Nichols1, E G DePuey, A Rozanski.   

Abstract

Both multicrystal and single-crystal detectors have been in use for more than 25 years for measurement of ejection fraction by analysis of images collected during the first-pass transit of radionuclides through the heart. Originally, multicrystal cameras were preferred, because they provided higher count rates than Anger cameras; however, over the years improvements in count rate capability and collimator design have enabled Anger cameras to perform equally well. This has become an important issue now that readily available 99mTc agents, such as sestamibi, enable evaluation of both myocardial function and perfusion from a single injection. The technical abilities of a particular camera determine which acquisition protocols are most likely to provide clinically useable images for the widest spectrum of patients. Electrocardiographic-gated list mode collection is highly desirable for first-pass imaging, providing the greatest flexibility of data review, rebinning, and analysis. Attention to quality control issues of data characterization and processing is important to ensure accuracy and precision of all measurements. Accurate determinations of ejection fraction of the left ventricle are possible routinely and, under favorable circumstances, of the right ventricle as well.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9138841     DOI: 10.1016/s1071-3581(97)90050-7

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  68 in total

1.  Evaluation of a clinical scintillation camera with pulse tail extrapolation electronics.

Authors:  T K Lewellen; A N Bice; K R Pollard; J B Zhu; M E Plunkett
Journal:  J Nucl Med       Date:  1989-09       Impact factor: 10.057

2.  Evaluation of the accuracy of steady-state krypton-81m method for calculating right ventricular ejection fraction.

Authors:  H R Ham; P R Franken; B Georges; E Delcourt; M Guillaume; A Piepsz
Journal:  J Nucl Med       Date:  1986-05       Impact factor: 10.057

3.  A new technique for assessing right ventricular ejection fraction using rapid multiple-gated equilibrium cardiac blood pool scintigraphy. Description, validation and findings in chronic coronary artery disease.

Authors:  J Maddahi; D S Berman; D T Matsuoka; A D Waxman; K E Stankus; J S Forrester; H J Swan
Journal:  Circulation       Date:  1979-09       Impact factor: 29.690

4.  Measurement of left heart ejection fraction and end-diastolic volume by a computerized, scintigraphic technique using a wedged pulmonary arterial catheter.

Authors:  P Steele; D Kirch; M Matthews; H Davies
Journal:  Am J Cardiol       Date:  1974-08       Impact factor: 2.778

5.  Rapid sequential visualization of the heart and great vessels in man using the wide-field anger scintillation camera. Radioisotope-angiography following the injection of technetium-99m.

Authors:  D T Mason; W L Ashburn; J C Harbert; L S Cohen; E Braunwald
Journal:  Circulation       Date:  1969-01       Impact factor: 29.690

6.  Krypton-81m imaging of the right ventricle.

Authors:  M Horn; K Witztum; C Neveu; G Perkins; B Walsh
Journal:  J Nucl Med       Date:  1985-01       Impact factor: 10.057

Review 7.  Recent advances in first-pass radionuclide angiography.

Authors:  S C Port
Journal:  Cardiol Clin       Date:  1994-05       Impact factor: 2.213

8.  Prognostic indicators from radionuclide angiography in medically treated patients with coronary artery disease.

Authors:  D B Pryor; F E Harrell; K L Lee; R A Rosati; R E Coleman; F R Cobb; R M Califf; R H Jones
Journal:  Am J Cardiol       Date:  1984-01-01       Impact factor: 2.778

9.  Stoichiometric Tc-99m RBC labeling using stable kit solutions of stannous chloride and EDTA: concise communication.

Authors:  B H Mock; H N Wellman
Journal:  J Nucl Med       Date:  1984-08       Impact factor: 10.057

10.  Perfusion and function at rest and treadmill exercise using technetium-99m-sestamibi: comparison of one- and two-day protocols in normal volunteers.

Authors:  S Borges-Neto; R E Coleman; R H Jones
Journal:  J Nucl Med       Date:  1990-07       Impact factor: 10.057

View more
  3 in total

1.  First-pass radionuclide angiography.

Authors:  John D Friedman; Daniel S Berman; Salvador Borges-Neto; Sean W Hayes; Lynne L Johnson; Kenneth J Nichols; Robert A Pagnanelli; Steven C Port
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

2.  Feasibility and operator variability of myocardial blood flow and reserve measurements with ⁹⁹mTc-sestamibi quantitative dynamic SPECT/CT imaging.

Authors:  Ran Klein; Guang-Uei Hung; Tao-Cheng Wu; Wen-Sheng Huang; Dianfu Li; Robert A deKemp; Bailing Hsu
Journal:  J Nucl Cardiol       Date:  2014-10-04       Impact factor: 5.952

3.  A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential.

Authors:  Moshe Bocher; Ira M Blevis; Leonid Tsukerman; Yigal Shrem; Gil Kovalski; Lana Volokh
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-29       Impact factor: 9.236

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.