Literature DB >> 6365478

Continuous monitoring of mixed venous oxygen saturation.

M B Divertie, J C McMichan.   

Abstract

Continuous monitoring of arterial oxygen tension is not sufficiently accurate for practical use in adults. Because of the shape of the hemoglobin dissociation curve, fluctuations at higher levels of oxygen tension are not reflected by corresponding changes in saturation; consequently, measurement of saturation at these levels also lacks sensitivity in detecting physiologic instability. However, at the lower levels of oxygen present in venous blood, a linear relationship exists between saturation and tension. The use of improved fiberoptic oximetry systems in conventional pulmonary artery flotation catheters has made the bedside application of this relationship of practical value in the continuous assessment of mixed venous oxygen saturation. Our own experience with it extends to more than 630 patients. Changes predictive of cardiorespiratory instability and instantaneous response to nursing or therapeutic maneuvers make this technique highly effective in the care of the critically ill.

Entities:  

Mesh:

Substances:

Year:  1984        PMID: 6365478     DOI: 10.1378/chest.85.3.423

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  12 in total

1.  Chest diseases: continuous monitoring of mixed venous oxygen saturation.

Authors:  S C Yang; J R Dexter
Journal:  West J Med       Date:  1986-03

2.  Simultaneous in vivo comparison of two-versus three-wavelength mixed venous (Svo2) oximetry catheters.

Authors:  F Bongard; T S Lee; T Leighton; S Y Liu
Journal:  J Clin Monit       Date:  1995-09

3.  Continuous monitoring of mixed venous oxygen saturation in septic shock.

Authors:  D Heiselman; J Jones; L Cannon
Journal:  J Clin Monit       Date:  1986-10

4.  Continuous monitoring of mixed venous oxygen saturation in infants after cardiac surgery.

Authors:  D Schranz; S Schmitt; H Oelert; F Schmid; R Huth; B Zimmer; A Schuind; K Vogel; H Stopfkuchen; B K Jüngst
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

5.  Continuous central venous oxygen saturation (ScvO2) measurement using a fibre optic catheter in newborn infants.

Authors:  M A van der Hoeven; W J Maertzdorf; C E Blanco
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1996-05       Impact factor: 5.747

6.  History of blood gas analysis. VI. Oximetry.

Authors:  J W Severinghaus; P B Astrup
Journal:  J Clin Monit       Date:  1986-10

7.  Continuous venous oximetry in surgical patients.

Authors:  L D Nelson
Journal:  Ann Surg       Date:  1986-03       Impact factor: 12.969

8.  Anesthetic management of pediatric patients following fontan operation.

Authors:  Akiko Yamashita; Yukio Hayashi; Noriko Horinokuchi; Yoshihiko Ohnishi; Masakazu Kuro
Journal:  J Anesth       Date:  1997-03       Impact factor: 2.078

Review 9.  Anaesthesia for abdominal aortic surgery--a review (Part II).

Authors:  A J Cunningham
Journal:  Can J Anaesth       Date:  1989-09       Impact factor: 5.063

10.  Hemodynamic changes during whole bronchoalveolar lavage in two cases of pulmonary alveolar proteinosis.

Authors:  M A Aguinaga; P Santos; E Renes; P F Alvaro; J A Lorente; A Maudes; R R Diaz; L Landín; D Liste
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.