Literature DB >> 3097269

Continuous monitoring of mixed venous oxygen saturation in septic shock.

D Heiselman, J Jones, L Cannon.   

Abstract

Fiberoptic pulmonary artery catheters provide a practical method for continuously measuring the amount of oxygen in mixed venous blood. To characterize the usefulness of mixed venous oxygen saturation in managing patients with sepsis, we performed serial hemodynamic measurements on 20 patients with documented septic shock. There was a highly significant positive correlation between increases or decreases of 5% or more in mixed venous oxygen saturation and corresponding changes in oxygen delivery (r = 0.95) and oxygen consumption (r = 0.96). Mixed venous oxygen saturation less than 65% was clinically unacceptable in patients with sepsis and was associated with a poor prognosis. In this study, measurement of mixed venous oxygen saturation was a valuable predictor of survival in patients with septic shock and provided a means of continuously monitoring the status of tissue oxygenation.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3097269     DOI: 10.1007/bf02851172

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  17 in total

1.  Complications of pulmonary artery catheterization in the care of critically ill patients. A prospective study.

Authors:  C G Elliott; G A Zimmerman; T P Clemmer
Journal:  Chest       Date:  1979-12       Impact factor: 9.410

2.  Mixed venous oxygen saturation. Its role in the assessment of the critically ill patient.

Authors:  G Kandel; A Aberman
Journal:  Arch Intern Med       Date:  1983-07

3.  The use of mixed venous blood gas determinations in traumatic shock.

Authors:  K K Kazarian; L R Del Guercio
Journal:  Ann Emerg Med       Date:  1980-04       Impact factor: 5.721

4.  Continuous monitoring of mixed venous oxygen saturation in critically ill patients.

Authors:  P L Baele; J C McMichan; H M Marsh; J C Sill; P A Southorn
Journal:  Anesth Analg       Date:  1982-06       Impact factor: 5.108

5.  Clinical evaluation of a new fiberoptic catheter oximeter during cardiac surgery.

Authors:  J L Waller; J A Kaplan; D I Bauman; J M Craver
Journal:  Anesth Analg       Date:  1982-08       Impact factor: 5.108

6.  Importance of mixed venous oxygen saturation in the care of critically ill patients.

Authors:  A G de la Rocha; J F Edmonds; W G Williams; C Poirier; R N Trusler
Journal:  Can J Surg       Date:  1978-05       Impact factor: 2.089

7.  Continuous monitoring of mixed venous oxygen saturation in cardiac surgery.

Authors:  W R Jamieson; K W Turnbull; A J Larrieu; W A Dodds; J C Allison; G F Tyers
Journal:  Can J Surg       Date:  1982-09       Impact factor: 2.089

8.  Sequential cardiorespiratory patterns associated with outcome in septic shock.

Authors:  E Abraham; R D Bland; J C Cobo; W C Shoemaker
Journal:  Chest       Date:  1984-01       Impact factor: 9.410

9.  Use of continuous monitoring of mixed venous saturation in the coronary care unit.

Authors:  J M Gore; K Sloan
Journal:  Chest       Date:  1984-11       Impact factor: 9.410

10.  Mixed venous oxygen saturation in relation to cardiac output in myocardial infarction.

Authors:  A L Muir; B J Kirby; A J King; H C Miller
Journal:  Br Med J       Date:  1970-10-31
View more
  7 in total

1.  Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock.

Authors:  Marjut Varpula; Sari Karlsson; Esko Ruokonen; Ville Pettilä
Journal:  Intensive Care Med       Date:  2006-07-07       Impact factor: 17.440

2.  Neutropenic patient with fever and abdominal pain.

Authors:  Hallie Metz; Carrie Tibbles
Journal:  Intern Emerg Med       Date:  2008-03       Impact factor: 3.397

3.  On-line computer estimation of carbon dioxide response curves.

Authors:  N W Goodman
Journal:  J Clin Monit       Date:  1987-07

4.  Mixed venous O2 saturation: measured by co-oximetry versus calculated from PVO2.

Authors:  D M Nierman; C B Schechter
Journal:  J Clin Monit       Date:  1994-01

5.  Vasopressin in vasodilatory shock: ensure organ blood flow, but take care of the heart!

Authors:  Martin W Dünser; Walter R Hasibeder
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

6.  Non-invasively Measured Venous Oxygen Saturation as Early Marker of Impaired Oxygen Delivery in Preterm Neonates.

Authors:  Lukas P Mileder; Julia Buchmayer; Nariae Baik-Schneditz; Bernhard Schwaberger; Nina Höller; Chad C Andersen; Michael J Stark; Gerhard Pichler; Berndt Urlesberger
Journal:  Front Pediatr       Date:  2022-01-28       Impact factor: 3.418

7.  Peripheral measurements of venous oxygen saturation and lactate as a less invasive alternative for hemodynamic monitoring.

Authors:  Raphaelle Avigael Chemtob; Hasse Møller-Sørensen
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2018-09-10       Impact factor: 2.953

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.