Accuracy and precision of quantitative calibrated loops in transfer of bronchoalveolar lavage fluid.

J A Jacobs1, E I De Brauwer, E I Cornelissen, M Drent.   

Abstract

Quantitative cultures of bronchoalveolar lavage (BAL) fluid are important in the diagnosis of ventilator-associated pneumonia, and calibrated loops are commonly used to set up these cultures. In this study, the performances of calibrated 0.010- and 0.001-ml loops in the transfer of BAL fluid were determined. Five loops of one lot from seven manufacturers were tested. Calibrations were performed by the gravimetric method (0.010-ml loops) and the colorimetric method (0.001-ml loops). Most of the 0.010-ml loops displayed a precision that was less than 10%, but six of them showed very poor accuracies as they transferred a deficiency (nichrome loops) or an excess (disposable loops) of BAL fluid that exceeded +/-10%. The mean maximum and minimum BAL fluid volumes delivered by the 0.010-ml loops differed by a factor 3. The 0.001-ml loops displayed acceptable precision. Five of them showed inaccuracies of </=+/-10%, and mean maximum and minimum BAL fluid volumes had a range of a factor of 2. For all loops, the volumes of BAL fluid sampled were larger than the volumes of reagent-grade water sampled. Results of the colony counting experiments confirmed these findings and revealed a high intra-assay variability for the 0.001-ml loops. We conclude that, when BAL fluid samples are cultured with calibrated loops, (i) proper verification of the calibration of these loops is mandatory, (ii) calibrations should be performed with BAL fluid as the test solution, and (iii) borderline quantitative culture results should be interpreted with knowledge of the inaccuracy values of these loops.

Entities:  

Mesh:

Year:  2000        PMID: 10834963      PMCID: PMC86741          DOI: 10.1128/JCM.38.6.2117-2121.2000

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  19 in total

Review 1.  The standardization of bronchoscopic techniques for ventilator-associated pneumonia.

Authors:  G U Meduri; J Chastre
Journal:  Chest       Date:  1992-11       Impact factor: 9.410

2.  Diagnostic fiberoptic bronchoscopy and protected brush culture in patients with community-acquired pneumonia.

Authors:  A Ortqvist; M Kalin; L Lejdeborn; B Lundberg
Journal:  Chest       Date:  1990-03       Impact factor: 9.410

3.  Detection of non-infectious conditions mimicking pneumonia in the intensive care setting: usefulness of bronchoalveolar fluid cytology.

Authors:  J A Jacobs; E I De Brauwer; G Ramsay; N A Cobben; S S Wagenaar; A J van der Ven; C A Bruggeman; M Drent
Journal:  Respir Med       Date:  1999-08       Impact factor: 3.415

4.  Bronchoalveolar lavage for diagnosing acute bacterial pneumonia.

Authors:  J E Thorpe; R P Baughman; P T Frame; T A Wesseler; J L Staneck
Journal:  J Infect Dis       Date:  1987-05       Impact factor: 5.226

5.  Accuracy of calibrated-loop transfer.

Authors:  A C Albers; R D Fletcher
Journal:  J Clin Microbiol       Date:  1983-07       Impact factor: 5.948

6.  Low specificity of the bacterial index for the diagnosis of bacterial pneumonia by bronchoalveolar lavage.

Authors:  R Speich; M Hauser; T Hess; J Wüst; E Grebski; F H Kayser; E W Russi
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1998-02       Impact factor: 3.267

7.  Usefulness of microscopic examination of intracellular organisms in lavage fluid in ventilator-associated pneumonia.

Authors:  J Solé-Violán; F Rodríguez de Castro; A Rey; J C Martín-González; P Cabrera-Navarro
Journal:  Chest       Date:  1994-09       Impact factor: 9.410

8.  Comparative efficacy of bronchoalveolar lavage and telescoping plugged catheter in the diagnosis of pneumonia in mechanically ventilated patients.

Authors:  J Solé Violán; F Rodríguez de Castro; J Caminero Luna; A Bordes Benítez; J L Manzano Alonso
Journal:  Chest       Date:  1993-02       Impact factor: 9.410

9.  Use of bronchoalveolar lavage to diagnose bacterial pneumonia in mechanically ventilated patients.

Authors:  L F Guerra; R P Baughman
Journal:  Crit Care Med       Date:  1990-02       Impact factor: 7.598

10.  Quantitative culture of bronchoalveolar lavage fluid for the diagnosis of bacterial pneumonia.

Authors:  D E Cantral; T G Tape; E C Reed; J R Spurzem; S I Rennard; A B Thompson
Journal:  Am J Med       Date:  1993-12       Impact factor: 4.965

View more
  10 in total

1.  Phaeohyphomycosis caused by Alternaria infectoria in a renal transplant recipient.

Authors:  T Halaby; H Boots; A Vermeulen; A van der Ven; H Beguin; H van Hooff; J Jacobs
Journal:  J Clin Microbiol       Date:  2001-05       Impact factor: 5.948

2.  Quantitative cultures of bronchoscopically obtained specimens should be performed for optimal management of ventilator-associated pneumonia.

Authors:  Vickie Baselski; J Stacey Klutts; Vickie Baselski; J Stacey Klutts
Journal:  J Clin Microbiol       Date:  2013-01-02       Impact factor: 5.948

3.  Detection of Streptococcus pneumoniae antigen in bronchoalveolar lavage fluid samples by a rapid immunochromatographic membrane assay.

Authors:  Jan A Jacobs; Ellen E Stobberingh; Elisa I M Cornelissen; Marjolein Drent
Journal:  J Clin Microbiol       Date:  2005-08       Impact factor: 5.948

4.  Herpes simplex virus load in bronchoalveolar lavage fluid is related to poor outcome in critically ill patients.

Authors:  Catharina F M Linssen; Jan A Jacobs; Foekje F Stelma; Walther N K A van Mook; Peter Terporten; Cornelis Vink; Marjolein Drent; Cathrien A Bruggeman; Annick Smismans
Journal:  Intensive Care Med       Date:  2008-08-05       Impact factor: 17.440

5.  Influence of antibiotic therapy on the cytological diagnosis of ventilator-associated pneumonia.

Authors:  Catharina F M Linssen; Jan A Jacobs; Jan S A G Schouten; Walther N K A van Mook; Graham Ramsay; Marjolein Drent
Journal:  Intensive Care Med       Date:  2008-02-05       Impact factor: 17.440

6.  Clara cell protein in bronchoalveolar lavage fluid: a predictor of ventilator-associated pneumonia?

Authors:  Marijke J Vanspauwen; Catharina F M Linssen; Cathrien A Bruggeman; Jan A Jacobs; Marjolein Drent; Dennis C J J Bergmans; Walther N K A van Mook
Journal:  Crit Care       Date:  2011-01-11       Impact factor: 9.097

7.  Low saliva pH can yield false positives results in simple RT-LAMP-based SARS-CoV-2 diagnostic tests.

Authors:  Cristina Uribe-Alvarez; Quynh Lam; Don A Baldwin; Jonathan Chernoff
Journal:  PLoS One       Date:  2021-05-05       Impact factor: 3.240

8.  Soluble Triggering Receptor Expressed on Myeloid cells-1 in bronchoalveolar lavage fluid is not predictive for ventilator-associated pneumonia.

Authors:  Guy J Oudhuis; Judith Beuving; Dennis Bergmans; Ellen E Stobberingh; Guul ten Velde; Catharina F Linssen; Annelies Verbon
Journal:  Intensive Care Med       Date:  2009-04-03       Impact factor: 17.440

9.  Mimivirus is not a frequent cause of ventilator-associated pneumonia in critically ill patients.

Authors:  M J Vanspauwen; R M Schnabel; C A Bruggeman; M Drent; W N K A van Mook; D C J J Bergmans; C F M Linssen
Journal:  J Med Virol       Date:  2013-07-16       Impact factor: 2.327

10.  Multiple cross displacement amplification-a more applicable technique in detecting Pseudomonas aeruginosa of ventilator-associated pneumonia (VAP).

Authors:  Juxiang Wang; Huimin Chen; Xiaomin Lin; Chengyi Ji; Bin Chen
Journal:  Crit Care       Date:  2020-06-08       Impact factor: 9.097

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.