Literature DB >> 615887

Emission computer assisted tomography with single-photon and positron annihilation photon emitters.

T F Budinger, S E Derenzo, G T Gullberg, W L Greenberg, R H Huesman.   

Abstract

Computed transverse section emission tomography using 99mTc with the Anger camera is compared to positron annihilation coincident detection using a ring of crystals and 68Ga. The single-photon system has a line spread function (LSF) of 9 mm full width at half maximum (FWHM) at the collimator and gives a transverse section reconstruction LSF of 11 mm FWHM with 144 views. The positron ring has a LSF of 6 mm at the center with a transverse section reconstruction LSF of 7.5 mm FWHM. Correction for uniformity of detector response and accurate center of rotation determination is essential in both techniques. The signal-to-noise ratio in a reconstruction is diminished by a factor of 1.2 x (number of resolution elements)1/4 over that expected from the average number of events per resolution element. Attenuation compensation causes more noise to appear in the center than the edge for both modes and an average increase in uncertainty of 30%. The effects of attenuation result in more loss of data for positron coincidence imaging than for single-photon imaging even at energies of 80 keV. For a 20-cm cylinder imaged in transverse section, only 20% of the positron annihilation events are not scattered; however, at 140 keV, 40% of the photons are not scattered. The relative crystal efficiency gives single-photon imaging an advantage of 5. On the other hand, the solid angle advantage of positron photon coincidence imaging is about 100 for the comparisons of this paper. Taking these factors into account, we find positron-computed section imaging has a tenfold increase in sensitivity over multiple-view imaging with the scintillation camera, which gives multiple sections but requires camera or patient rotation.

Entities:  

Mesh:

Year:  1977        PMID: 615887     DOI: 10.1097/00004728-197701000-00015

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  17 in total

1.  RADIONUCLIDE COMPUTED TOMOGRAPHY: APPLICATIONS IN CARDIOVASCULAR DISEASE.

Authors:  Paul H. Murphy; John A. Burdine
Journal:  Cardiovasc Dis       Date:  1979-09

2.  A brain phantom for studying contrast recovery in emission computerized tomography.

Authors:  A Pupi; M T De Cristofaro; A R Formiconi; A Passeri; A Speranzi; E Giraudo; U Meldolesi
Journal:  Eur J Nucl Med       Date:  1990

Review 3.  Instrumentation for molecular imaging in preclinical research: Micro-PET and Micro-SPECT.

Authors:  Arion F Chatziioannou
Journal:  Proc Am Thorac Soc       Date:  2005

4.  Paediatric doses--a critical appraisal of the EANM paediatric dosage card.

Authors:  Søren Holm; Lise Borgwardt; Annika Loft; Jesper Graff; Ian Law; Liselotte Højgaard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-11       Impact factor: 9.236

5.  Design and fabrication of phantoms using stereolithography for small-animal imaging systems.

Authors:  Mi-Ae Park; Robert E Zimmerman; Andrew Taberner; Michael W Kaye; Stephen C Moore
Journal:  Mol Imaging Biol       Date:  2008-06-11       Impact factor: 3.488

6.  Emission tomography of the heart: principles and applications.

Authors:  J S Zielonka; B L Holman
Journal:  Cardiovasc Radiol       Date:  1979-09

7.  Comparison of transaxial resolution in 180 degrees and 360 degrees SPECT with a rotating scintillation camera.

Authors:  A N Bice; M Clausen; S Loncaric; H N Wagner
Journal:  Eur J Nucl Med       Date:  1987

8.  Non-stationary spatial filtering and accelerated curve fitting for parametric imaging with dynamic PET.

Authors:  K Herholz
Journal:  Eur J Nucl Med       Date:  1988

9.  PET tomography in studies of distributions of 7.6-min potassium 38 in the dog heart.

Authors:  W G Myers; R E Bigler; M C Graham
Journal:  Eur J Nucl Med       Date:  1984

10.  Emission computerized axial tomography from multiple gamma-camera views using frequency filtering.

Authors:  J L Pelletier; C Milan; C Touzery; P Coitoux; P Gailliard; T F Budinger
Journal:  Eur J Nucl Med       Date:  1980
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.