Comparison of transaxial resolution in 180 degrees and 360 degrees SPECT with a rotating scintillation camera.

A N Bice, M Clausen, S Loncaric, H N Wagner.   

Abstract

Using circular 180 degrees and 360 degrees SPECT acquisition modes the transaxial resolution of line sources in air and water were measured at different positions in the field of view. With the 180 degrees acquisition mode, all line sources in air located off the axis of camera rotation (AoR) showed an oval distortion. This distortion was systematically related to the starting point of the rotating detector. On axis line sources in air were undistorted, regardless of the 180 degrees acquisition starting angle. The 360 degrees acquisition images of the line sources in air showed a similar effect but in a very mild form. In water, transaxial reconstructions of line sources (off axis) showed an enhancement of the oval distortion for both the 180 degrees and 360 degrees acquisitions. Computer simulations of the line source measurements were performed and correlated well with the experimental data. The line source results are explainable by the inherent depth dependent response of the scintillation camera. In clinical SPECT studies, distortions of this nature will be most appreciable with 180 degrees imaging of small organs that are located off the AoR.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3496221     DOI: 10.1007/BF00252638

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  12 in total

1.  Clinical evaluation of 360 degrees and 180 degrees data sampling techniques for transaxial SPECT thallium-201 myocardial perfusion imaging.

Authors:  R T Go; W J MacIntyre; T S Houser; M Pantoja; J K O'Donnell; D H Feiglin; B J Sufka; D A Underwood; T F Meaney
Journal:  J Nucl Med       Date:  1985-07       Impact factor: 10.057

2.  Gamma camera emission tomography. Development and properties of a multi-sectional emission computed tomography system.

Authors:  S A Larsson
Journal:  Acta Radiol Suppl       Date:  1980

3.  Lesion detection with single-photon emission computed tomography (SPECT) compared with conventional imaging.

Authors:  R J Jaszczak; F R Whitehead; C B Lim; R E Coleman
Journal:  J Nucl Med       Date:  1982-02       Impact factor: 10.057

4.  Physical attributes of single-photon tomography.

Authors:  T F Budinger
Journal:  J Nucl Med       Date:  1980-06       Impact factor: 10.057

5.  Multiple photon coincidence tomography.

Authors:  V Chung; K C Chak; P Zacuto; H E Hart
Journal:  Semin Nucl Med       Date:  1980-10       Impact factor: 4.446

6.  Radionuclide axial tomography by half back-projection.

Authors:  J F Isenberg; W Simon
Journal:  Phys Med Biol       Date:  1978-01       Impact factor: 3.609

7.  Comparative study of thallium emission myocardial tomography with 180 degrees and 360 degrees data collection.

Authors:  N Tamaki; T Mukai; Y Ishii; T Fujita; K Yamamoto; K Minato; Y Yonekura; S Tamaki; H Kambara; C Kawai; K Torizuka
Journal:  J Nucl Med       Date:  1982-08       Impact factor: 10.057

8.  Comparison of 180 degrees and 360 degrees data collection in thallium-20 1 imaging using single-photon emission computerized tomography (SPECT): concise communication.

Authors:  R E Coleman; R J Jaszczak; F R Cobb
Journal:  J Nucl Med       Date:  1982-08       Impact factor: 10.057

9.  180 degrees compared with 360 degrees sampling in SPECT.

Authors:  E J Hoffman
Journal:  J Nucl Med       Date:  1982-08       Impact factor: 10.057

10.  Emission computer assisted tomography with single-photon and positron annihilation photon emitters.

Authors:  T F Budinger; S E Derenzo; G T Gullberg; W L Greenberg; R H Huesman
Journal:  J Comput Assist Tomogr       Date:  1977-01       Impact factor: 1.826

View more
  4 in total

1.  Why does SPECT work?

Authors:  Stephen L Bacharach
Journal:  J Nucl Cardiol       Date:  2006 May-Jun       Impact factor: 5.952

2.  Correction of partial volume effects in myocardial SPECT.

Authors:  B F Hutton; A Osiecki
Journal:  J Nucl Cardiol       Date:  1998 Jul-Aug       Impact factor: 5.952

3.  Clinical comparison of 180-degree and 360-degree data collection of technetium 99m sestamibi SPECT for detection of coronary artery disease.

Authors:  M R Freeman; C Konstantinou; A Barr; N D Greyson
Journal:  J Nucl Cardiol       Date:  1998 Jan-Feb       Impact factor: 5.952

4.  The importance of population-specific normal database for quantification of myocardial ischemia: comparison between Japanese 360 and 180-degree databases and a US database.

Authors:  Kenichi Nakajima; Koichi Okuda; Masaya Kawano; Shinro Matsuo; Piotr Slomka; Guido Germano; Seigo Kinuya
Journal:  J Nucl Cardiol       Date:  2009-02-04       Impact factor: 5.952

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.