Literature DB >> 560824

Valve replacement with the Starr-Edwards and Hancock prostheses: comparative analysis of late morbidity and mortality.

P E Oyer, E B Stinson, R B Griepp, N E Shumway.   

Abstract

Although the Starr-Edwards caged-ball valve remains a standard of comparison for more recently introduced prostheses, a substantial incidence of thromboembolic and hemorrhagic complications prompted our evaluation of the Hancock glutaraldehyde-fixed porcine xenograft. We have compared the results of 435 aortic valve replacements using the Starr- Edwards valve (SE-AVR), 515 mitral valve replacements (SE-MVR), and 121 double-valve replacements (SE-AVRMVR) with 251 aortic valve replacements using the xenograft aortic valve (X-AVR), 338 mitral valve replacements (X-MVR), and 88 double-valve replacements (X-AVR-MVR). The Starr- Edwards valves were used during the period 1963 through 1973 and the xenograft valves between 1971 and 1976. No significant differences in patient age, sex, or preoperative hemodynamic data were noted between comparable groups. All patients with Starr-Edwards valves received long-term anticoagulation while anticoagulants were used only for specific indications in patients with xenograft valves. Total follow up was 3944 patient years for the Starr-Edwards patients and 947 patient years for the xenograft patients. Hospital mortality was not significantly different for comparable groups: SE-AVR 6.9% vs. X-AVR 6.4%, SE-MVR 9.7% vs X-MVR 8.6%, and SE-AVR-MVR 7.5% vs. X-AVR-MVR 10.2%. Linearized mortality and morbidity data expressed as percent per patient- year are tabulated below. Pairs which differ significantly (p < .05) are italicized.

Entities:  

Mesh:

Year:  1977        PMID: 560824      PMCID: PMC1396340          DOI: 10.1097/00000658-197709000-00008

Source DB:  PubMed          Journal:  Ann Surg        ISSN: 0003-4932            Impact factor:   12.969


  7 in total

1.  A GENERALIZED WILCOXON TEST FOR COMPARING ARBITRARILY SINGLY-CENSORED SAMPLES.

Authors:  E A GEHAN
Journal:  Biometrika       Date:  1965-06       Impact factor: 2.445

2.  Maximum utilization of the life table method in analyzing survival.

Authors:  S J CUTLER; F EDERER
Journal:  J Chronic Dis       Date:  1958-12

3.  Profound local hypothermia for myocardial protection during open-heart surgery.

Authors:  R B Griepp; E B Stinson; N E Shumway
Journal:  J Thorac Cardiovasc Surg       Date:  1973-11       Impact factor: 5.209

4.  The analysis and presentation of surgical results by actuarial methods.

Authors:  R P Anderson; L I Bonchek; G L Grunkemeier; L E Lambert; A Starr
Journal:  J Surg Res       Date:  1974-03       Impact factor: 2.192

5.  The flexible stent. A new concept in the fabrication of tissue heart valve prostheses.

Authors:  R L Reis; W D Hancock; J W Yarbrough; D L Glancy; A G Morrow
Journal:  J Thorac Cardiovasc Surg       Date:  1971-11       Impact factor: 5.209

6.  Ball valve prostheses: current appraisal of late results.

Authors:  L I Bonchek; A Starr
Journal:  Am J Cardiol       Date:  1975-06       Impact factor: 2.778

7.  Long-term experience with porcine aortic valve xenografts.

Authors:  E B Stinson; R B Griepp; P E Oyer; N E Shumway
Journal:  J Thorac Cardiovasc Surg       Date:  1977-01       Impact factor: 5.209

  7 in total
  8 in total

1.  Observations on glutaraldehyde-treated heterologous cardiac valves.

Authors:  E Bodnar; E G Olsen; D N Ross
Journal:  Thorax       Date:  1979-12       Impact factor: 9.139

2.  Long-term complications of valve replacement.

Authors:  C M Oakley
Journal:  Br Med J (Clin Res Ed)       Date:  1982-04-03

3.  Mitral replacement: clinical experience with a ball-valve prosthesis. Twenty-five years later.

Authors:  A Cobanoglu; G L Grunkemeier; G M Aru; C L McKinley; A Starr
Journal:  Ann Surg       Date:  1985-09       Impact factor: 12.969

Review 4.  Plasminogen activators and ischemic stroke: conditions for acute delivery.

Authors:  Gregory J del Zoppo
Journal:  Semin Thromb Hemost       Date:  2013-03-28       Impact factor: 4.180

5.  Kay's mitral valve repair for mitral regurgitation due to ruptured chordae tendineae--clinical and hemodynamic observations.

Authors:  K Matsui; A Sese; H Kado; H Yasui; J Tanaka; M Komori; K Tokunaga
Journal:  Jpn J Surg       Date:  1983-03

Review 6.  Bioengineering aspects of heart valve replacement.

Authors:  F J Schoen; J L Titus; G M Lawrie
Journal:  Ann Biomed Eng       Date:  1982       Impact factor: 3.934

7.  Clinical experience with the Ionescu-Shiley xenograft valve: four to five-year follow-up.

Authors:  J B García-Bengochea; M F Siebert; C I Carreño; A A Cendon; J R Alvarez
Journal:  Tex Heart Inst J       Date:  1982-09

8.  Ten year clinical evaluation of Starr-Edwards 2400 and 1260 aortic valve prostheses.

Authors:  D Hackett; I Fessatidis; R Sapsford; C Oakley
Journal:  Br Heart J       Date:  1987-04
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.