Literature DB >> 556634

Long-term experience with porcine aortic valve xenografts.

E B Stinson, R B Griepp, P E Oyer, N E Shumway.   

Abstract

Between 1971 and 1975, glutaraldehyde-preserved porcine aortic valve xenografts were employed for isolated replacement of the mitral valve (MVR) in 243 patients, replacement of the aortic valve (AVR) in 167 patients, and double valve replacement (AVR and MVR) in 51 patients. Postoperatively, long-term anticoagulation was not routinely given. Operative mortality rates for AVR, MVR, and double valve groups were 7.8, 6.0, and 11.8 per cent, respectively; the majority of early postoperative deaths were associated with concomitant coronary artery disease. No death was attributable to xenograft dysfunction. Follow-up of all patients was obtained. The total duration of follow-up for the MVR group was 347 patient-years, for the AVR GROUP 148 148 patient-years, and for double valve replacement 37 patient-years; maximum follow-up for these three groups was 4.4, 4.0, and 2.4 years, respectively. Actuarial analysis of postoperative survival rates at a common interval of 3 years showed 78 per cent for MVR patients, 91 per cent for AVR patients, and 80 per cent (projected) for patients with double valve replacement (85, 96, and 91 per cent for operative survivors, respectively. At this same interval 92 per cent of MVR patients, 99 per cent of AVR patients, and 93 per cent (projected) of patients with double valve replacement were free of thromboembolic episodes. Altogether, 12 of the total 512 valves implanted exhibited some evidence of dysfunction during the entire period of follow-up evaluation, but in only 2 instances (both mitral) was intrinsic pathological involvement of the xenograft tissue documented. Actuarial analysis of xenograft dysfunction at a common interval of 3 years after operation showed 95 per cent of MVR patients, 98 per cent of AVR patients, and 97 per cent (projected) of patients with double valve replacement to be free of this complication. These data support the use of glutaraldehyde-preserved porcine xenografts as superior bioprostheses that pose a low risk of thromboembolism without anticoagulation. The over-all durability of such valves, within the restriction of a maximum current follow-up interval of 4.4 years, appears comparable to that of currently available mechanical prostheses and justifies continued clinical use.

Entities:  

Mesh:

Year:  1977        PMID: 556634

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  16 in total

1.  Influence of fixation conditions on the performance of glutaraldehyde-treated porcine aortic valves: towards a more scientific basis.

Authors:  N D Broom; F J Thomson
Journal:  Thorax       Date:  1979-04       Impact factor: 9.139

2.  A new biologic prosthesis for vascular substitute in mongrel dogs.

Authors:  L A Marquez-Zacarias; A R Rey; M C Heine; J J Manrique
Journal:  Tex Heart Inst J       Date:  1985-09

3.  Long-term results in 1375 patients undergoing valve replacement with the Starr-Edwards cloth-covered steel ball prosthesis.

Authors:  O W Isom; S E Glassman; P Teiko; A D Boyd; J N Cunningham; G E Reed
Journal:  Ann Surg       Date:  1977-09       Impact factor: 12.969

4.  Clinical and haemodynamic evaluation of mounted porcine heterograft in mitral position.

Authors:  L Cotter; H C Miller
Journal:  Br Heart J       Date:  1979-04

5.  Severe and early stenosis of porcine heterograft mitral valve.

Authors:  J C Forfar; L Cotter; G N Morritt
Journal:  Br Heart J       Date:  1978-10

6.  Thrombotic complications after valve replacement with porcine heterografts.

Authors:  R Hetzer; F Gerbode; W J Kerth; J D Hill; G M Adappa
Journal:  World J Surg       Date:  1979-08-31       Impact factor: 3.352

7.  Clinical, hemodynamic, and operative descriptors affecting outcome of aortic valve replacement in elderly versus young patients.

Authors:  J M Craver; J Goldstein; E L Jones; W A Knapp; C R Hatcher
Journal:  Ann Surg       Date:  1984-06       Impact factor: 12.969

8.  Severe late failure of a porcine xenograft mitral valve: clinical, echocardiographic, and pathological findings.

Authors:  G Crupi; D Gibson; B Heard; C Lincoln
Journal:  Thorax       Date:  1980-03       Impact factor: 9.139

9.  Chordal rupture. II: comparison between repair and replacement.

Authors:  D B Oliveira; K D Dawkins; P H Kay; M Paneth
Journal:  Br Heart J       Date:  1983-10

10.  Chordal rupture. I: aetiology and natural history.

Authors:  D B Oliveira; K D Dawkins; P H Kay; M Paneth
Journal:  Br Heart J       Date:  1983-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.