Literature DB >> 6887669

Kay's mitral valve repair for mitral regurgitation due to ruptured chordae tendineae--clinical and hemodynamic observations.

K Matsui, A Sese, H Kado, H Yasui, J Tanaka, M Komori, K Tokunaga.   

Abstract

Kay's mitral valve repair was performed in six consecutive patients with symptomatic mitral regurgitation due to ruptured chordae tendineae of the posterior leaflet. All patients including one with mild residual murmur showed a marked decrease in the heart size and significant clinical improvement. Postoperative hemodynamic studies, performed in four patients, showed restoration of normal or near-normal dynamics. The medium-term follow-up, 15 to 30 months after the operation, revealed continuing asymptomatic states in all. The function of the repaired valves was significantly better than that of the Hancock mitral bioprostheses. The advantages of this procedure compared with mitral valve replacement for the same condition were stressed.

Entities:  

Mesh:

Year:  1983        PMID: 6887669     DOI: 10.1007/bf02469526

Source DB:  PubMed          Journal:  Jpn J Surg        ISSN: 0047-1909


  21 in total

1.  The repair of mitral insufficiency associated with ruptured chordae tendineae.

Authors:  J H KAY; W S EGERTON
Journal:  Ann Surg       Date:  1963-03       Impact factor: 12.969

2.  Hydraulic formula for calculation of the area of the stenotic mitral valve, other cardiac valves, and central circulatory shunts. I.

Authors:  R GORLIN; S G GORLIN
Journal:  Am Heart J       Date:  1951-01       Impact factor: 4.749

3.  Pathology of the myxomatous mitral value. Nature, secondary changes and complications.

Authors:  R B Guthrie; J E Edwards
Journal:  Minn Med       Date:  1976-09

Review 4.  Pathology and valvular heart disease.

Authors:  A Pomerance
Journal:  Br Heart J       Date:  1972-05

5.  Hemodynamic evaluation of Lillehei-Kaiser and Starr-Edwards prosthesis.

Authors:  R B Pyle; J E Mayer; W G Lindsay; C R Jorgensen; Y Wang; D M Nicoloff
Journal:  Ann Thorac Surg       Date:  1978-10       Impact factor: 4.330

6.  Prosthetic valve endocarditis. Comparison of heterograft tissue valves and mechanical valves.

Authors:  S J Rossiter; E B Stinson; P E Oyer; D C Miller; J N Schapira; R P Martin; N E Shumway
Journal:  J Thorac Cardiovasc Surg       Date:  1978-12       Impact factor: 5.209

7.  Mitral valve repair for significant mitral insufficiency.

Authors:  J H Kay; P Zubiate; M A Mendez; N Vanstrom; T Yokoyama
Journal:  Am Heart J       Date:  1978-08       Impact factor: 4.749

8.  Year of operation as a risk factor in the late results of valve replacement.

Authors:  Q Macmanus; G L Grunkemeier; L E Lambert; J F Teply; B J Harlan; A Starr
Journal:  J Thorac Cardiovasc Surg       Date:  1980-12       Impact factor: 5.209

9.  Long-term clinical and hemodynamic evaluation of the Ionescu-Schiley pericardial xenograft and the Braunwald-Cutter and Björk-Shiley prostheses in the mitral position.

Authors:  A P Tandon; S M Sengupta; L Lukacs; M I Ionescu
Journal:  J Thorac Cardiovasc Surg       Date:  1978-12       Impact factor: 5.209

10.  Valve replacement with the Starr-Edwards and Hancock prostheses: comparative analysis of late morbidity and mortality.

Authors:  P E Oyer; E B Stinson; R B Griepp; N E Shumway
Journal:  Ann Surg       Date:  1977-09       Impact factor: 12.969

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.