Literature DB >> 492076

Noise considerations in dual energy CT scanning.

F Kelcz, P M Joseph, S K Hilal.   

Abstract

Dual energy CT scanning (tomochemistry) has been proposed as a method for determining various parameters relating to the elemental composition of the tissues. In this paper, our aim is to study the relative noise inherent in two proposed techniques for dual energy scanning; a "two crystal" technique and a "two kV" technique. In the two crystal technique, a split crystal detector is used to simultaneously obtain the high and low energy data during one scan at high kV. The two kV technique requires two scans taken with widely different kV settings. We first review three commonly used approaches for utilizing the scan data to compute the relevant parameters. A theoretical formalism is constructed which aids in understanding these methods. Then this formalism is used to study the influence of CT image noise on measurement precision in the case where the unknown parameters are densities. It is shown that, (1) the unavoidable overlap in the spectral data obtained by the two crystal technique results in a much lower signal-to-noise ratio than can be obtained by using the two kV technique, (2) the necessity for hard filtration of the high energy beam in the two kV technique has not heretofore been appreciated, and (3) the dose for a given x-ray tube heat load is also lower with the two kV technique.

Mesh:

Year:  1979        PMID: 492076     DOI: 10.1118/1.594520

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  45 in total

1.  Virtual monochromatic imaging in dual-source dual-energy CT: radiation dose and image quality.

Authors:  Lifeng Yu; Jodie A Christner; Shuai Leng; Jia Wang; Joel G Fletcher; Cynthia H McCollough
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Radiation dose reduction in computed tomography: techniques and future perspective.

Authors:  Lifeng Yu; Xin Liu; Shuai Leng; James M Kofler; Juan C Ramirez-Giraldo; Mingliang Qu; Jodie Christner; Joel G Fletcher; Cynthia H McCollough
Journal:  Imaging Med       Date:  2009-10

3.  In vivo differentiation of complementary contrast media at dual-energy CT.

Authors:  John Mongan; Samira Rathnayake; Yanjun Fu; Runtang Wang; Ella F Jones; Dong-Wei Gao; Benjamin M Yeh
Journal:  Radiology       Date:  2012-07-09       Impact factor: 11.105

4.  Material differentiation by dual energy CT: initial experience.

Authors:  Thorsten R C Johnson; Bernhard Krauss; Martin Sedlmair; Michael Grasruck; Herbert Bruder; Dominik Morhard; Christian Fink; Sabine Weckbach; Miriam Lenhard; Bernhard Schmidt; Thomas Flohr; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-12-07       Impact factor: 5.315

5.  Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration.

Authors:  A N Primak; J C Ramirez Giraldo; X Liu; L Yu; C H McCollough
Journal:  Med Phys       Date:  2009-04       Impact factor: 4.071

6.  Measurement of breast tissue composition with dual energy cone-beam computed tomography: a postmortem study.

Authors:  Huanjun Ding; Justin L Ducote; Sabee Molloi
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

Review 7.  Vision 20/20: Single photon counting x-ray detectors in medical imaging.

Authors:  Katsuyuki Taguchi; Jan S Iwanczyk
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

8.  Cascaded systems analysis of noise and detectability in dual-energy cone-beam CT.

Authors:  Grace J Gang; Wojciech Zbijewski; J Webster Stayman; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-08       Impact factor: 4.071

9.  Quantitative imaging of element composition and mass fraction using dual-energy CT: three-material decomposition.

Authors:  Xin Liu; Lifeng Yu; Andrew N Primak; Cynthia H McCollough
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

Review 10.  Anniversary paper. Development of x-ray computed tomography: the role of medical physics and AAPM from the 1970s to present.

Authors:  Xiaochuan Pan; Jeffrey Siewerdsen; Patrick J La Riviere; Willi A Kalender
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.