Literature DB >> 472014

The direct use of CT numbers in radiotherapy dosage calculations for inhomogeneous media.

R P Parker, P A Hobday, K J Cassell.   

Abstract

Techniques by which the quantitative anatomical data inherent in a CT scan can be directly used in treatment planning are described. The correction algorithms used in the RAD-8 system, based on an effective path length, have been extended to a pixel-by-pixel approach. By calibrating the X-ray transmission CT scanner in terms of electron densities (electron cm-3) inhomogeneity corrections may be made automatically.

Mesh:

Year:  1979        PMID: 472014     DOI: 10.1088/0031-9155/24/4/011

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Computed tomography as a source of electron density information for radiation treatment planning.

Authors:  Witold Skrzyński; Sylwia Zielińska-Dabrowska; Marta Wachowicz; Wioletta Slusarczyk-Kacprzyk; Paweł F Kukołowicz; Wojciech Bulski
Journal:  Strahlenther Onkol       Date:  2010-05-17       Impact factor: 3.621

2.  Influence of intravenous contrast agent on dose calculation in 3-D treatment planning for radiosurgery of cerebral arteriovenous malformations.

Authors:  Angelika Zabel-du Bois; Benjamin Ackermann; Henrik Hauswald; Oliver Schramm; Gabriele Sroka-Perez; Peter Huber; Jürgen Debus; Stefanie Milker-Zabel
Journal:  Strahlenther Onkol       Date:  2009-05-15       Impact factor: 3.621

3.  Evaluation of raw-data-based and calculated electron density for contrast media with a dual-energy CT technique.

Authors:  Daisuke Kawahara; Shuichi Ozawa; Kazushi Yokomachi; Toru Higaki; Takehiro Shiinoki; Yoshimi Ohno; Yuji Murakami; Kazuo Awai; Yasushi Nagata
Journal:  Rep Pract Oncol Radiother       Date:  2019-08-20

4.  On the molecular relationship between Hounsfield Unit (HU), mass density, and electron density in computed tomography (CT).

Authors:  Atchar Sudhyadhom
Journal:  PLoS One       Date:  2020-12-31       Impact factor: 3.240

Review 5.  Dual-energy CT: minimal essentials for radiologists.

Authors:  Fuminari Tatsugami; Toru Higaki; Yuko Nakamura; Yukiko Honda; Kazuo Awai
Journal:  Jpn J Radiol       Date:  2022-01-04       Impact factor: 2.701

6.  A simple manual method to estimate water-equivalent diameter for calculating size-specific dose estimate in chest computed tomography.

Authors:  Dimitris Mihailidis; Virginia Tsapaki; Pelagia Tomara
Journal:  Br J Radiol       Date:  2020-10-15       Impact factor: 3.039

7.  Investigation of the usability of conebeam CT data sets for dose calculation.

Authors:  Anne Richter; Qiaoqiao Hu; Doreen Steglich; Kurt Baier; Jürgen Wilbert; Matthias Guckenberger; Michael Flentje
Journal:  Radiat Oncol       Date:  2008-12-16       Impact factor: 3.481

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.