Improved imaging of the cervico-thoracic junction in computed tomography.

Pyong Kon Cho1, Young Hen Lee, You Hyun Kim, Jong Hak Choi, Dong Chul Shin, Tae Kyu Choi, Jang Seob Kim, Ki Hyun Kim, Sun Ung Kim.   

Abstract

PURPOSE: To reduce beam hardening artifacts caused by the shoulder joint, we explored new and unique methods to improve the quality of images, such as varying the injection site and changing the position of patients (swimmers position).
MATERIALS AND METHODS: Fifth-four patients underwent neck CT examinations performed in routine and swimmers position and with a 64-slice MDCT scanner in spiral scanning. To examine the difference due to the injection sites of contrast material, subjects were divided into right- and left-side groups. For the evaluation of images, we carried out a subjective and objective assessment based on radiologists' ratings and noise measurement.
RESULTS: Images of the lower neck in the swimmers position exhibited less hardening and streak artifacts. The subjective and objective evaluations showed that the swimmers position received higher rating by radiologists and had lower noise level than that of routine position. The swimmers position was the most effective for the diagnosis of the cervico-thoracic junction area. As for the injection site, we obtained better images by an injection of contrast material in the right arm than in the left.
CONCLUSION: CT examination of the lower neck in the swimmers position may improve the quality of image and the effectiveness of diagnosis. The injection of a contrast material to the right side rather than the left side reduced foreign body artifacts.

Entities:  

Mesh:

Year:  2008        PMID: 18306474      PMCID: PMC2615274          DOI: 10.3349/ymj.2008.49.1.84

Source DB:  PubMed          Journal:  Yonsei Med J        ISSN: 0513-5796            Impact factor:   2.759


  16 in total

1.  Cone-beam computed tomography with a flat-panel imager: magnitude and effects of x-ray scatter.

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2001-02       Impact factor: 4.071

2.  Local computed tomography via iterative deblurring.

Authors:  G Wang; D L Snyder; M W Vannier
Journal:  Scanning       Date:  1996-11       Impact factor: 1.932

3.  Computerized transverse axial scanning (tomography). 1. Description of system.

Authors:  G N Hounsfield
Journal:  Br J Radiol       Date:  1973-12       Impact factor: 3.039

4.  Correction for spectral artifacts in cross-sectional reconstruction from x rays.

Authors:  W D McDavid; R G Waggener; W H Payne; M J Dennis
Journal:  Med Phys       Date:  1977 Jan-Feb       Impact factor: 4.071

5.  The removal of a "cupping" artefact from brain images produced by the EMI 7070 CT scanner.

Authors:  D J Mott; G L Zheng; B Eddleston
Journal:  Br J Radiol       Date:  1985-09       Impact factor: 3.039

6.  Iterative reconstruction--reprojection: an algorithm for limited data cardiac-computed tomography.

Authors:  M Nassi; W R Brody; B P Medoff; A Macovski
Journal:  IEEE Trans Biomed Eng       Date:  1982-05       Impact factor: 4.538

7.  CT of metal implants: reduction of artifacts using an extended CT scale technique.

Authors:  T M Link; W Berning; S Scherf; U Joosten; A Joist; K Engelke; H E Daldrup-Link
Journal:  J Comput Assist Tomogr       Date:  2000 Jan-Feb       Impact factor: 1.826

8.  Swimmer's CT: improved imaging of the lower neck and thoracic inlet.

Authors:  Arthur G Kane; Kevin C Reilly; Thomas F Murphy
Journal:  AJNR Am J Neuroradiol       Date:  2004-05       Impact factor: 3.825

9.  Efficacy of limited CT for nonvisualized lower cervical spine in patients with blunt trauma.

Authors:  J Tehranzadeh; R T Bonk; A Ansari; M Mesgarzadeh
Journal:  Skeletal Radiol       Date:  1994-07       Impact factor: 2.199

10.  Computed tomography reconstruction from hollow projections: an application to in vivo evaluation of artificial hip joints.

Authors:  T Hinderling; P Rüegsegger; M Anliker; C Dietschi
Journal:  J Comput Assist Tomogr       Date:  1979-02       Impact factor: 1.826

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.