Very fast MR imaging by field echoes and small angle excitation.

P van der Meulen, J P Groen, J J Cuppen.   

Abstract

An MR imaging technique has been developed producing head and body images of diagnostic quality in only a few seconds acquisition time. The Fourier type imaging technique uses excitation with relatively small excitation angels, echoes produced by gradient inversion, and extremely fast profile repetition. A typical result at 0.5 T is an artifact-free head image of 128 x 128 resolution, 10 mm slice thickness in an acquisition time of 2 seconds.

Mesh:

Year:  1985        PMID: 4079679     DOI: 10.1016/0730-725x(85)90362-5

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  11 in total

Review 1.  [Magnetic resonance imaging. Sequence acronyms and other abbreviations in MR imaging].

Authors:  W R Nitz
Journal:  Radiologe       Date:  2003-09       Impact factor: 0.635

2.  Evaluation of MR cisternography of the cerebellopontine angle using a balanced fast-field-echo sequence: preliminary findings.

Authors:  Kazuhiro Tsuchiya; Chinatsu Aoki; Junichi Hachiya
Journal:  Eur Radiol       Date:  2003-10-03       Impact factor: 5.315

3.  Multiple slice FLASH imaging: an improved pulse sequence for contrast enhanced MR brain studies.

Authors:  W Schörner; B Sander; H Henkes; T Heim; W Lanksch; R Felix
Journal:  Neuroradiology       Date:  1990       Impact factor: 2.804

Review 4.  Tools for cardiovascular magnetic resonance imaging.

Authors:  Ramkumar Krishnamurthy; Benjamin Cheong; Raja Muthupillai
Journal:  Cardiovasc Diagn Ther       Date:  2014-04

5.  Enhanced phase regression with Savitzky-Golay filtering for high-resolution BOLD fMRI.

Authors:  Robert L Barry; John C Gore
Journal:  Hum Brain Mapp       Date:  2014-01-17       Impact factor: 5.038

6.  Data-driven optimization and evaluation of 2D EPI and 3D PRESTO for BOLD fMRI at 7 Tesla: I. Focal coverage.

Authors:  Robert L Barry; Stephen C Strother; J Christopher Gatenby; John C Gore
Journal:  Neuroimage       Date:  2011-01-11       Impact factor: 6.556

7.  MRI of the knee joint with a 3-D gradient echo sequence. Equivalent to diagnostic arthroscopy?

Authors:  K Glückert; B Kladny; A Blank-Schäl; G Hofmann
Journal:  Arch Orthop Trauma Surg       Date:  1992       Impact factor: 3.067

8.  Multi-shot acquisitions for stimulus-evoked spinal cord BOLD fMRI.

Authors:  Robert L Barry; Benjamin N Conrad; Satoshi Maki; Jennifer M Watchmaker; Lydia J McKeithan; Bailey A Box; Quinn R Weinberg; Seth A Smith; John C Gore
Journal:  Magn Reson Med       Date:  2020-11-10       Impact factor: 4.668

9.  On the origins of signal variance in FMRI of the human midbrain at high field.

Authors:  Robert L Barry; Mariam Coaster; Baxter P Rogers; Allen T Newton; Jay Moore; Adam W Anderson; David H Zald; John C Gore
Journal:  PLoS One       Date:  2013-04-26       Impact factor: 3.240

Review 10.  Cardiovascular magnetic resonance physics for clinicians: part I.

Authors:  John P Ridgway
Journal:  J Cardiovasc Magn Reson       Date:  2010-11-30       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.