Histopathologic evaluation of prolonged intracortical electrical stimulation.

W F Agnew, T G Yuen, D B McCreery, L A Bullara.   

Abstract

Chronic stimulating microelectrodes fabricated from platinum-30% iridium (Pt-30%Ir) or activated iridium were implanted in assemblies of three in the left sensorimotor cortex of the cat and pulsed continuously at currents of 10 to 320 microA (100 to 3200 microC/cm2 X ph, 2 to 64 nC/ph) for periods of 24 h or for 23 h/day for 7 days. The microelectrodes had beveled tips with uninsulated geometric surface areas of 20 X 10(-6) cm2. Neuronal activity evoked by the focal stimulation was monitored by recording compound action potentials from the ipsilateral pyramidal tract. By this criterion neuronal activation thresholds were 5 to 15 microA (50 to 150 microC/cm2 X ph, 1 to 3 nC/ph) for both types of electrodes. Histologic evaluations of tissue surrounding the electrode tips were carried out by either light or electron microscopy. No neural damage was induced by 24 or 161 h of pulsing using either type of electrode at currents of 10 to 80 microA. Neural damage attributable to electrical stimulation per se was observed in a few sites pulsed with 320 microA (3200 microC/cm2 X ph, 64 nC/ph, 16 A/cm2) with Pt-30%Ir but not activated iridium electrodes of the same size. Electrode dissolution appears to be best correlated with charge density and current density. Dissolution of the Pt-30%Ir microelectrode tip was observed by scanning electron microscopy at charge densities as low as 200 microC/cm2 X ph (1 A/cm2), whereas erosion of activated iridium microelectrodes occurred only at the highest charge and current densities (3200 microC/cm2 X ph, 16 A/cm2). Thus, the activated iridium electrode is superior to Pt-30%Ir for chronic stimulations, from the standpoint of electrode tip stability, because with the former, in contrast to the alloy, detectable erosion occurred only at an intensity well above that required for activation of nearby neurons.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3956647     DOI: 10.1016/0014-4886(86)90132-9

Source DB:  PubMed          Journal:  Exp Neurol        ISSN: 0014-4886            Impact factor:   5.330


  21 in total

1.  Microelectrode Guided Implantation of Electrodes into the Subthalamic Nucleus of Rats for Long-term Deep Brain Stimulation.

Authors:  Felix Fluri; Micheal Bieber; Jens Volkmann; Christoph Kleinschnitz
Journal:  J Vis Exp       Date:  2015-10-02       Impact factor: 1.355

2.  A neuron model of stochastic resonance using rectangular pulse trains.

Authors:  Zachary Danziger; Warren M Grill
Journal:  J Comput Neurosci       Date:  2014-09-05       Impact factor: 1.621

3.  Intraocular retinal prosthesis.

Authors:  M S Humayun
Journal:  Trans Am Ophthalmol Soc       Date:  2001

4.  Comparison of wire and disc leads to activate the expiratory muscles in dogs.

Authors:  Krysztof E Kowalski; Anthony F DiMarco
Journal:  J Spinal Cord Med       Date:  2011-11       Impact factor: 1.985

5.  The development of neural stimulators: a review of preclinical safety and efficacy studies.

Authors:  Robert K Shepherd; Joel Villalobos; Owen Burns; David A X Nayagam
Journal:  J Neural Eng       Date:  2018-05-14       Impact factor: 5.379

6.  Neural electrode degradation from continuous electrical stimulation: comparison of sputtered and activated iridium oxide.

Authors:  Sandeep Negi; Rajmohan Bhandari; Loren Rieth; Rick Van Wagenen; Florian Solzbacher
Journal:  J Neurosci Methods       Date:  2009-10-28       Impact factor: 2.390

Review 7.  Bionic intrafascicular interfaces for recording and stimulating peripheral nerve fibers.

Authors:  Ranu Jung; James J Abbas; Sathyakumar Kuntaegowdanahalli; Anil K Thota
Journal:  Bioelectron Med (Lond)       Date:  2017-12-14

8.  A cognitive neuroprosthetic that uses cortical stimulation for somatosensory feedback.

Authors:  Christian Klaes; Ying Shi; Spencer Kellis; Juri Minxha; Boris Revechkis; Richard A Andersen
Journal:  J Neural Eng       Date:  2014-09-22       Impact factor: 5.379

9.  Micro-Coil Design Influences the Spatial Extent of Responses to Intracortical Magnetic Stimulation.

Authors:  Krishnan Thyagarajan; Shelley I Fried
Journal:  IEEE Trans Biomed Eng       Date:  2018-10-23       Impact factor: 4.538

10.  Chronic intracochlear electrical stimulation at high charge densities results in platinum dissolution but not neural loss or functional changes in vivo.

Authors:  Robert K Shepherd; Paul M Carter; Ya Lang Enke; Andrew K Wise; James B Fallon
Journal:  J Neural Eng       Date:  2018-12-05       Impact factor: 5.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.