A comparative study of the measurement of mean arterial blood pressure using automatic oscillometers, arterial cannulation and auscultation.

A J Rutten, A H Ilsley, G A Skowronski, W B Runciman.   

Abstract

Mean brachial artery pressures determined by five different non-invasive automatic oscillometric and one auscultatory preferred (oscillometric back-up) blood pressure (BP) monitors were compared with mean arterial pressures (MAP) obtained by cannulation of the radial artery of the same arm. The devices tested all performed similarly, showing a wide range of variation (+40% to -29%) compared with the directly measured MAP, and all tended to over-read at low values and under-read at high values. Trend information was generally acceptable, but occasionally was misleading. In addition, using one of the devices, systolic and diastolic blood pressure measurements were compared with those obtained by auscultation. This gives a range of differences from +22 to -25 mmHg for systolic and +20 to -12 mmHg for diastolic BP measurements. (The average fell within 1.0 mmHg of the auscultatory measurement, with a standard deviation of 10 mmHg.) Thus, the automatic oscillometric BP monitors tested were comparable in accuracy to auscultatory BP measurement, and are satisfactory for routine use in the appropriate clinical context. However, in settings where significance is to be attached to individual BP readings rather than to trends, or where a high degree of accuracy is required, automatic oscillometric machines cannot be regarded as satisfactory alternatives to arterial cannulation.

Mesh:

Year:  1986        PMID: 3954015     DOI: 10.1177/0310057X8601400113

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  11 in total

1.  Accuracy of four indirect methods of blood pressure measurement, with hemodynamic correlations.

Authors:  G P Gravlee; J K Brockschmidt
Journal:  J Clin Monit       Date:  1990-10

2.  The relative accuracies of two automated noninvasive arterial pressure measurement devices.

Authors:  M S Gorback; T J Quill; M L Lavine
Journal:  J Clin Monit       Date:  1991-01

3.  Theoretical analysis of non-invasive oscillometric maximum amplitude algorithm for estimating mean blood pressure.

Authors:  P D Baker; D R Westenskow; K Kück
Journal:  Med Biol Eng Comput       Date:  1997-05       Impact factor: 2.602

4.  Accuracy of oscillometric blood pressure measurement in critically ill neonates with reference to the arterial pressure wave shape.

Authors:  M Gevers; H R van Genderingen; H N Lafeber; W W Hack
Journal:  Intensive Care Med       Date:  1996-03       Impact factor: 17.440

5.  The Dinamap 1846SX automated blood pressure recorder: comparison with the Hawksley random zero sphygmomanometer under field conditions.

Authors:  P H Whincup; N G Bruce; D G Cook; A G Shaper
Journal:  J Epidemiol Community Health       Date:  1992-04       Impact factor: 3.710

6.  Indirect blood pressure measurement using the Riva Rocci Korotkoff method.

Authors:  H H Ros
Journal:  J Clin Monit       Date:  1995-03

7.  A poor correlation exists between oscillometric and radial arterial blood pressure as measured by the Philips MP90 monitor.

Authors:  Samuel A Mireles; Richard A Jaffe; David R Drover; John G Brock-Utne
Journal:  J Clin Monit Comput       Date:  2009-04-25       Impact factor: 2.502

8.  Comparison of intraarterial with continuous noninvasive blood pressure measurement in postoperative pediatric patients.

Authors:  J K Triedman; J P Saul
Journal:  J Clin Monit       Date:  1994-01

9.  Comparison of the sphygmooscillographic method with the direct and auscultatory methods of measuring blood pressure.

Authors:  A Sapinski
Journal:  J Clin Monit       Date:  1994-11

10.  Noninvasive techniques for blood pressure measurement are not a reliable alternative to direct measurement: a randomized crossover trial in ICU.

Authors:  Sara Ribezzo; Eleonora Spina; Stefano Di Bartolomeo; Gianfranco Sanson
Journal:  ScientificWorldJournal       Date:  2014-01-30