Literature DB >> 3948389

Graphical comparisons of interferences in clinical chemistry instrumentation.

M R Glick, K W Ryder, S A Jackson.   

Abstract

Instrument- and analyte-specific interferences can be produced by adding known concentrations of potentially interfering substances to serum from healthy volunteers. Analytical results are expressed as a percentage of the original (unaffected) result. Graphical displays of the transformed data document the conditions under which erroneous results would be probable for specimens containing the additive. If several analytical systems are available, one can make an informed choice of which to use for a particular analysis by comparing the appropriate graphical information. Comparisons of such displays of data from newer systems being considered for purchase may facilitate decisions regarding laboratory instrumentation.

Mesh:

Substances:

Year:  1986        PMID: 3948389

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  33 in total

1.  Negative interference of bilirubin and hemoglobin in the MEIA troponin I assay but not in the MEIA CK-MB assay.

Authors:  A Dasgupta; A Wells; D A Biddle
Journal:  J Clin Lab Anal       Date:  2001       Impact factor: 2.352

2.  Development of a microparticle-enhanced nephelometric immunoassay for quantitation of human lysozyme in pleural effusion and plasma.

Authors:  M Caballero; R Ruiz; M Márquez de Prado; M Seco; L Borque; J F Escanero
Journal:  J Clin Lab Anal       Date:  1999       Impact factor: 2.352

3.  Effects of hemolysis, lipemia, hyperbilirrubinemia, and anticoagulants in canine C-reactive protein, serum amyloid A, and ceruloplasmin assays.

Authors:  Silvi Martínez-Subiela; Jose J Cerón
Journal:  Can Vet J       Date:  2005-07       Impact factor: 1.008

4.  Effects of bilirubinemia, hemolysis, and lipemia on clinical chemistry analytes in bovine, canine, equine, and feline sera.

Authors:  R M Jacobs; J H Lumsden; E Grift
Journal:  Can Vet J       Date:  1992-09       Impact factor: 1.008

5.  Development and validation of 14 human serum protein assays on the Roche cobas® c 501.

Authors:  Thomas B Ledue; Marilyn F Collins
Journal:  J Clin Lab Anal       Date:  2011       Impact factor: 2.352

6.  External evaluation of the Dimension Vista 1500® intelligent lab system.

Authors:  Arnaud Bruneel; Monique Dehoux; Anne Barnier; Anne Boutten
Journal:  J Clin Lab Anal       Date:  2012-09       Impact factor: 2.352

7.  Preanalytical variables affecting the measurement of serum paraoxonase-1 activity in horses.

Authors:  Gabriele Rossi; Amy Richardson; Hali Jamaludin; Cristy Secombe
Journal:  J Vet Diagn Invest       Date:  2020-11-22       Impact factor: 1.279

8.  The influence of cobalt manganese ferrite nanoparticles (Co0.5Mn0.5Fe2O4) on reduction of hazardous effects of vanadate in adult rats.

Authors:  Mohamed M Rezk; Abdelghaffar S Dhmees; Mahmoud O Abd El-Magied; El-Sayed A Manaa; Hassan S El-Gendy
Journal:  Toxicol Res (Camb)       Date:  2020-04-20       Impact factor: 3.524

9.  Interference testing.

Authors:  Goce Dimeski
Journal:  Clin Biochem Rev       Date:  2008-08

10.  Effects of interferents on the kinetic Jaffé reaction and an enzymatic colorimetric test for serum creatinine concentration determination in cats, cows, dogs and horses.

Authors:  R M Jacobs; J H Lumsden; J A Taylor; E Grift
Journal:  Can J Vet Res       Date:  1991-04       Impact factor: 1.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.