Development of a microparticle-enhanced nephelometric immunoassay for quantitation of human lysozyme in pleural effusion and plasma.

M Caballero1, R Ruiz, M Márquez de Prado, M Seco, L Borque, J F Escanero.   

Abstract

A microparticle-enhanced nephelometric immunoassay, based on polystyrene beads coated with antihuman lysozyme antibody, has been developed for lysozyme quantification in sera and pleural effusions. The standard curve extends from 0.58 mg/l to 18.75 mg/l and no antigen effect was observed. The results showed a good serial precision. The intra-assay precision (n = 20) expressed as CV was between 2.2 and 4.2 in three different concentrations. The inter-assay precision, with different calibration curves (n = 12) was between 6.4 and 7.1. The analytical assay showed a sufficient linearity (r > 0.999). There were no interferences either with haemoglobin (up to 4 g/l), lipids (up to 0.5%, expressed as 1% Lipofundina content), or bilirubin (up to 5 mg/dl). The analytical sensitivity was lower than 0.6 mg/l. The correlation with a Micrococcus lysodeikticus turbidimetric assay showed a correlation coefficient of 0.915. We have studied 92 patients with pleural effusion. In each case, pleural fluid adenosine deaminase activity and pleural fluid to plasma lysozyme ratio were determined. The lysozyme ratio showed similar clinical sensitivity and specificity as to adenosine deaminase.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10633299      PMCID: PMC6807809          DOI: 10.1002/(sici)1098-2825(1999)13:6<301::aid-jcla9>3.0.co;2-3

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  22 in total

Review 1.  [Usefulness of biological markers in pleural effusion].

Authors:  J de M Díez; E A Peces; J L Alonso; J A Iglesias
Journal:  Rev Clin Esp       Date:  1996-02       Impact factor: 1.556

2.  Lysozyme in pleural effusions.

Authors:  T Pettersson; M Klockars; P E Hellström; B Fröseth
Journal:  Chest       Date:  1988-01       Impact factor: 9.410

3.  Diagnostic value of simultaneous determination of pleural adenosine deaminase and pleural lysozyme/serum lysozyme ratio in pleural effusions.

Authors:  J Fontan Bueso; H Verea Hernando; J P Garcia-Buela; L Dominguez Juncal; M T Martin Egaña; M C Montero Martinez
Journal:  Chest       Date:  1988-02       Impact factor: 9.410

4.  Changes in serum and urine lysozyme activity after kidney transplantation: influence of graft function and therapy with azathioprine.

Authors:  G Horpacsy; J Zinsmeyer; K Schröder; M Mebel
Journal:  Clin Chem       Date:  1978-01       Impact factor: 8.327

5.  Usefulness of serum lysozyme measurement in diagnosis and evaluation of sarcoidosis.

Authors:  R S Pascual; J B Gee; S C Finch
Journal:  N Engl J Med       Date:  1973-11-15       Impact factor: 91.245

6.  Automated turbidimetry of serum lipoprotein(a).

Authors:  L Borque; C Maside; A Iglesias
Journal:  Eur J Clin Chem Clin Biochem       Date:  1993-12

7.  Determination of urinary lysozyme for potential detection of tubular dysfunction in diabetic nephropathy.

Authors:  K Shima; M Hirota; M Fukuda; A Tanaka
Journal:  Clin Chem       Date:  1986-10       Impact factor: 8.327

8.  Meaning and diagnostic value of determining the lysozyme level of pleural fluid.

Authors:  H R Verea Hernando; J F Masa Jimenez; L Dominguez Juncal; J Perez Garcia-Buela; M T Martin Egaña; J Fontan Bueso
Journal:  Chest       Date:  1987-03       Impact factor: 9.410

9.  Radioimmunoassay for serum and urinary lysozyme.

Authors:  M J Thomas; A Russo; P Craswell; M Ward; I Steinhardt
Journal:  Clin Chem       Date:  1981-07       Impact factor: 8.327

10.  Measurement of lysozyme in human body fluids: comparison of various enzyme immunoassay techniques and their diagnostic application.

Authors:  B Porstmann; K Jung; H Schmechta; U Evers; M Pergande; T Porstmann; H J Kramm; H Krause
Journal:  Clin Biochem       Date:  1989-10       Impact factor: 3.281

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.