Literature DB >> 21254244

Development and validation of 14 human serum protein assays on the Roche cobas® c 501.

Thomas B Ledue1, Marilyn F Collins.   

Abstract

Many laboratories rely on dedicated nephelometers and turbidimeters for the measurement of serum proteins. There are, however, a number of chemistry analyzers that offer open channel configurations for end-user applications. We developed and validated 14 human serum protein assays (α(1)-antitrypsin, α(2)-macroglobulin, albumin, apolipoproteins AI and B, complement components 3 and 4, haptoglobin, immunoglobulins A, G, and M, orosomucoid, transferrin, and transthyretin) on the Roche cobas(®) c 501. We obtained excellent precision at low, normal, and high physiologic concentrations of each protein (within-run imprecision CVs ≤2.5%, total imprecision CVs ≤3.6%). Linearity for each method was within 5% of the expected value throughout the calibration range, and method comparison studies to commercial assays from Roche or Siemens were in good agreement (r>0.975). We observed no significant interference from bilirubin (up to 414  mg/l), hemoglobin (up to 8.9  g/l), triglyceride (up to 28  g/l), or rheumatoid factor (up to 3,930 IU/ml). Calibration was stable for at least 14 days. The instrument's small reaction cell allowed us to conserve nearly 60% of our specimen and reagent volume compared with our previous system. These newly developed assays provide precise and accurate results with high throughput, but without the associated cost of a dedicated instrument.
© 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21254244      PMCID: PMC6647647          DOI: 10.1002/jcla.20430

Source DB:  PubMed          Journal:  J Clin Lab Anal        ISSN: 0887-8013            Impact factor:   2.352


  26 in total

1.  Effect of a new international reference preparation for proteins in human serum (certified reference material 470) on results of the College of American Pathologists Surveys for plasma proteins.

Authors:  A M Johnson; J T Whicher; T B Ledue; A Carlström; Y Itoh; P H Petersen
Journal:  Arch Pathol Lab Med       Date:  2000-10       Impact factor: 5.534

2.  Protein standardization IV: Value transfer procedure for the assignment of serum protein values from a reference preparation to a target material.

Authors:  S Blirup-Jensen; A M Johnson; M Larsen
Journal:  Clin Chem Lab Med       Date:  2001-11       Impact factor: 3.694

3.  Immunoturbidimetric assays of apolipoproteins A, AI, AII, and B in serum.

Authors:  N Rifai; M E King
Journal:  Clin Chem       Date:  1986-06       Impact factor: 8.327

4.  Overestimation of immunoglobulins in the presence of rheumatoid factor by kinetic immunonephelometry and rapid immunoturbidimetry.

Authors:  R E Chambers; J T Whicher; D E Perry; A Milford-Ward; P A White; R Fifield
Journal:  Ann Clin Biochem       Date:  1987-09       Impact factor: 2.057

5.  Incorrect least-squares regression coefficients in method-comparison analysis.

Authors:  P J Cornbleet; N Gochman
Journal:  Clin Chem       Date:  1979-03       Impact factor: 8.327

6.  A simple, direct, and sensitive technique for measurement of specific protein in dilute solution.

Authors:  R F Ritchie
Journal:  J Lab Clin Med       Date:  1967-09

7.  Method for testing antiserum titer and avidity in nephelometric systems.

Authors:  G A Hudson; R F Ritchie; J E Haddow
Journal:  Clin Chem       Date:  1981-11       Impact factor: 8.327

8.  A rate nephelometer for measuring specific proteins by immunoprecipitin reactions.

Authors:  J C Sternberg
Journal:  Clin Chem       Date:  1977-08       Impact factor: 8.327

9.  New assay of apolipoproteins A-I and B by rate nephelometry evaluated.

Authors:  J J Maciejko; S S Levinson; L Markyvech; M P Smith; R D Blevins
Journal:  Clin Chem       Date:  1987-11       Impact factor: 8.327

10.  Comparison of turbidimetric and light-scattering measurements of immunoglobulins by use of a centrifugal analyzer with absorbance and fluorescence/light-scattering optics.

Authors:  L P Hills; T O Tiffany
Journal:  Clin Chem       Date:  1980-09       Impact factor: 8.327

View more
  2 in total

1.  Liver morphometrics and metabolic blood profile across divergent phenotypes for feed efficiency in the bovine.

Authors:  Yuri Regis Montanholi; Livia Sadocco Haas; Kendall Carl Swanson; Brenda Lynn Coomber; Shigeto Yamashiro; Stephen Paul Miller
Journal:  Acta Vet Scand       Date:  2017-04-26       Impact factor: 1.695

2.  Influence of chronic training workload on the hematological profile: a pilot study in sedentary people, amateur and professional cyclists.

Authors:  Giuseppe Lippi; Fabian Sanchis-Gomar
Journal:  Acta Biomed       Date:  2020-11-10
  2 in total