Literature DB >> 393717

Identification of Enterobacteriaceae in frozen microdilution trays prepared by Micro-Media Systems.

A L Barry, R E Badal, L J Effinger.   

Abstract

Frozen microdilution trays, with 20 different biochemical test media for identification of Enterobactericeae, were evaluated. The test panels were those provided by Micro-Media Systems (MMS), who also provided a code book for interpretation of the test results. The interpretations of the MMS test system and of the Analytab API 20E test system were compared with those obtained from tests with conventional media. Tests with 468 Enterobacteriaceae demonstrated nearly comparable results with the two commercial systems. About 6% (API) and 7% (MMS) of the isolates could not be identified without additional tests, and another 3% (MMS) to 4% (API) of the isolates gave test patterns that were not found in the code books. One to three percent of the isolates were misidentified. It was concluded that the MMS Enteric Quad Panels provide an efficient, relatively inexpensive, and reasonably accurate method for identification of the Enterobacteriaceae.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 393717      PMCID: PMC273202          DOI: 10.1128/jcm.10.4.492-496.1979

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  4 in total

1.  Analysis of cost and accuracy of alternative strategies for Enterobacteriaceae identification.

Authors:  E A Robertson; G C Macks; J D MacLowry
Journal:  J Clin Microbiol       Date:  1976-04       Impact factor: 5.948

2.  Evaluation of the Repliscan system for identification of Enterobacteriaceae.

Authors:  S D Brown; J A Washington
Journal:  J Clin Microbiol       Date:  1978-12       Impact factor: 5.948

3.  Comparison of enteric identification systems.

Authors:  K A Borchardt; J Gibson
Journal:  Health Lab Sci       Date:  1977-01

4.  Evaluation of the micro-media system for quantitative antimicrobial drug susceptibility testing: a collaborative study.

Authors:  A L Barry; R N Jones; T L Gavan
Journal:  Antimicrob Agents Chemother       Date:  1978-01       Impact factor: 5.191

  4 in total
  7 in total

1.  Evaluation of the Quantum II and Rapid E identification systems.

Authors:  P R Murray; A Gauthier; A Niles
Journal:  J Clin Microbiol       Date:  1984-09       Impact factor: 5.948

2.  Evaluation of the Sensititre system for identification of Enterobacteriaceae.

Authors:  J L Staneck; J Vincelette; F Lamothe; E A Polk
Journal:  J Clin Microbiol       Date:  1983-04       Impact factor: 5.948

3.  Accuracy and precision of the autobac system for rapid identification of Gram-negative bacilli: a collaborative evaluation.

Authors:  A L Barry; T L Gavan; P B Smith; J M Matsen; J A Morello; B H Sielaff
Journal:  J Clin Microbiol       Date:  1982-06       Impact factor: 5.948

4.  Preliminary evaluation of the autoSCAN-3, an instrument for automated reading an interpretation of microdilution trays: identification of aerobic gram-negative bacilli.

Authors:  P D Ellner; D A Myers
Journal:  J Clin Microbiol       Date:  1981-09       Impact factor: 5.948

5.  Comparison of the automicrobic system with API, enterotube, micro-ID, micro-media systems, and conventional methods for identification of Enterobacteriaceae.

Authors:  M T Kelly; J M Latimer
Journal:  J Clin Microbiol       Date:  1980-11       Impact factor: 5.948

6.  Comparison of Enteric-Tek with API 20E and conventional methods for identification of Enterobacteriaceae.

Authors:  D A Bruckner; V Clark; W J Martin
Journal:  J Clin Microbiol       Date:  1982-01       Impact factor: 5.948

Review 7.  Recovery of uncommon bacteria from blood: association with neoplastic disease.

Authors:  J L Beebe; E W Koneman
Journal:  Clin Microbiol Rev       Date:  1995-07       Impact factor: 26.132

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.