Literature DB >> 3880349

An evaluation of variables influencing implant fixation by direct bone apposition.

K A Thomas1, S D Cook.   

Abstract

A systematic mechanical and histologic evaluation of design variables affecting bone apposition to various biocompatible materials was undertaken. The variables investigated included material elastic modulus, material surface texture, as well as material surface composition. The implant materials included polymethylmethacrylate (PMMA), low-temperature isotropic (LTI) pyrolytic carbon, commercially pure (C.P.) titanium, and aluminum oxide (Al2O3). Implant surface texture was varied by either polishing or grit-blasting the various materials. Implant surface composition was varied by applying a coating of ultra-low temperature isotropic (ULTI) pyrolytic carbon to the various implants. A total of 12 types of implants were evaluated in vivo by placement transcortically in the femora of adult mongrel dogs for a period of 32 weeks. Following sacrifice, mechanical push-out testing was performed to determine interface shear strength and interface shear stiffness. The results obtained from mechanical testing indicate that for implants fixed by direct bone apposition, interface stiffness and interface shear strength are not significantly affected by either implant elastic modulus or implant surface composition. Varying surface texture, however, significantly affected the interface response to the implants. For each elastic modulus group the roughened surfaced implants exhibited greater strengths than the corresponding smooth surfaced implants. Undecalcified histologic evaluation of the implants demonstrated that the roughened implants exhibited direct bone apposition, whereas the smooth implants exhibited various degrees of fibrous tissue encasement. Thus, for implants utilizing direct bone apposition fixation, it appears that of the parameters investigated, implant surface texture is the most significant.

Entities:  

Mesh:

Substances:

Year:  1985        PMID: 3880349     DOI: 10.1002/jbm.820190802

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  21 in total

Review 1.  Surface treatments and roughness properties of Ti-based biomaterials.

Authors:  Andrea Bagno; Carlo Di Bello
Journal:  J Mater Sci Mater Med       Date:  2004-09       Impact factor: 3.896

2.  Short-term and long-term effects of orthopedic biodegradable implants.

Authors:  Ami R Amini; James S Wallace; Syam P Nukavarapu
Journal:  J Long Term Eff Med Implants       Date:  2011

3.  No evidence to indicate topographic dependency on bone formation around cp titanium implants under masticatory loading.

Authors:  H Kawahara; H Aoki; H Koike; Y Soeda; D Kawahara; S Matsuda
Journal:  J Mater Sci Mater Med       Date:  2006-08       Impact factor: 3.896

4.  Electron microscopic investigation on the osteogenesis at titanium implant/bone marrow interface under masticatory loading.

Authors:  H Kawahara; S Nakakita; M Ito; K Niwa; D Kawahara; S Matsuda
Journal:  J Mater Sci Mater Med       Date:  2006-08       Impact factor: 3.896

5.  Novel fabrication of nano-rod array structures on titanium and in vitro cell responses.

Authors:  Yongxing Liu; Weihui Chen; Yunzhi Yang; Joo L Ong; Kanji Tsuru; Satoshi Hayakawa; Akiyoshi Osaka
Journal:  J Mater Sci Mater Med       Date:  2008-02-29       Impact factor: 3.896

6.  Effect of micrometer-scale roughness of the surface of Ti6Al4V pedicle screws in vitro and in vivo.

Authors:  Zvi Schwartz; Perry Raz; Ge Zhao; Yael Barak; Michael Tauber; Hai Yao; Barbara D Boyan
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

7.  Rapid prototyping amphiphilic polymer/hydroxyapatite composite scaffolds with hydration-induced self-fixation behavior.

Authors:  Artem B Kutikov; Anvesh Gurijala; Jie Song
Journal:  Tissue Eng Part C Methods       Date:  2014-08-20       Impact factor: 3.056

8.  Stability of dental implants after irradiation with an 830-nm low-level laser: a double-blind randomized clinical study.

Authors:  Joelle Marie García-Morales; Pedro Tortamano-Neto; Francisco Fernando Todescan; José Carlos Silva de Andrade; Juliana Marotti; Denise Maria Zezell
Journal:  Lasers Med Sci       Date:  2011-07-06       Impact factor: 3.161

Review 9.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

10.  Surface modification of implant materials and its effect on attachment and proliferation of bone cells.

Authors:  Hak-Kwan Kim; Ju-Woong Jang; Chang-Hee Lee
Journal:  J Mater Sci Mater Med       Date:  2004-07       Impact factor: 3.896

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.