Literature DB >> 15387419

Surface modification of implant materials and its effect on attachment and proliferation of bone cells.

Hak-Kwan Kim1, Ju-Woong Jang, Chang-Hee Lee.   

Abstract

Osteoblast-like cell response in variation with the air plasma sprayed (APS) TiO2 coating process parameters correlated with coating properties were investigated to evaluate the durability and biocompatibility of the surface-modified implant. The Taguchi technique was used to determine the coating properties affected by plasma spraying parameters on Ti-6AI-4V alloy substrate. The coating properties were characterized by porosity and surface roughness using an image analyzer and surf analyzer, respectively. The MG-63 osteoblast like cell morphology and proliferation data on TiO2 coated substrate were measured by SEM observation and direct cell counting. It was demonstrated that surface roughness increased as spray distance decreased but gas flow rates and spray distance were major factors in the case of porosity. The osteoblast adhesion morphology and proliferation data indicated that osteoblast-like cell morphology was not influenced by process parameters, but cell proliferation was affected to some extent by surface roughness and porosity among TiO2 coated specimens. Specifically, the difference between those of substrate and coating layer was relatively more visible.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15387419     DOI: 10.1023/b:jmsm.0000032824.62866.a1

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  18 in total

Review 1.  Effects of synthetic micro- and nano-structured surfaces on cell behavior.

Authors:  R G Flemming; C J Murphy; G A Abrams; S L Goodman; P F Nealey
Journal:  Biomaterials       Date:  1999-03       Impact factor: 12.479

2.  The relative influence of the topography and chemistry of TiAl6V4 surfaces on osteoblastic cell behaviour.

Authors:  K Anselme; P Linez; M Bigerelle; D Le Maguer; A Le Maguer; P Hardouin; H F Hildebrand; A Iost; J M Leroy
Journal:  Biomaterials       Date:  2000-08       Impact factor: 12.479

3.  Optimization of surface micromorphology for enhanced osteoblast responses in vitro.

Authors:  K T Bowers; J C Keller; B A Randolph; D G Wick; C M Michaels
Journal:  Int J Oral Maxillofac Implants       Date:  1992       Impact factor: 2.804

4.  Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs.

Authors:  D Buser; R K Schenk; S Steinemann; J P Fiorellini; C H Fox; H Stich
Journal:  J Biomed Mater Res       Date:  1991-07

5.  Characterization of the interface in the plasma-sprayed HA coating/Ti-6Al-4V implant system.

Authors:  M J Filiaggi; N A Coombs; R M Pilliar
Journal:  J Biomed Mater Res       Date:  1991-10

6.  Human arthroplasty derived macrophages differentiate into osteoclastic bone resorbing cells.

Authors:  A Sabokbar; Y Fujikawa; S Neale; D W Murray; N A Athanasou
Journal:  Ann Rheum Dis       Date:  1997-07       Impact factor: 19.103

7.  An indirect comparison of third-body wear in retrieved hydroxyapatite-coated, porous, and cemented femoral components.

Authors:  T W Bauer; S K Taylor; M Jiang; S V Medendorp
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

8.  An evaluation of variables influencing implant fixation by direct bone apposition.

Authors:  K A Thomas; S D Cook
Journal:  J Biomed Mater Res       Date:  1985-10

9.  Complications with hydroxyapatite particulate separation in total hip arthroplasty.

Authors:  R D Bloebaum; D Beeks; L D Dorr; C G Savory; J A DuPont; A A Hofmann
Journal:  Clin Orthop Relat Res       Date:  1994-01       Impact factor: 4.176

10.  Differential effects of different forms of hydroxyapatite and hydroxyapatite/tricalcium phosphate particulates on human monocyte/macrophages in vitro.

Authors:  Y Harada; J T Wang; V A Doppalapudi; A A Willis; M Jasty; W H Harris; M Nagase; S R Goldring
Journal:  J Biomed Mater Res       Date:  1996-05
View more
  10 in total

1.  In situ roughening of polymeric microstructures.

Authors:  Hamed Shadpour; Nancy L Allbritton
Journal:  ACS Appl Mater Interfaces       Date:  2010-04       Impact factor: 9.229

2.  In vitro biocompatibility and corrosion resistance of a new implant titanium base alloy.

Authors:  E Vasilescu; P Drob; D Raducanu; V D Cojocaru; I Cinca; D Iordachescu; R Ion; M Popa; C Vasilescu
Journal:  J Mater Sci Mater Med       Date:  2010-03-25       Impact factor: 3.896

3.  PLD bioactive ceramic films: the influence of CaO-P2O5 glass additions to hydroxyapatite on the proliferation and morphology of osteblastic like-cells.

Authors:  Gisela Marta Oliveira; Maria P Ferraz; Pío G González; Julia Serra; Betty Leon; Mariano Pèrez-Amor; Fernando J Monteiro
Journal:  J Mater Sci Mater Med       Date:  2007-12-06       Impact factor: 3.896

4.  Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys.

Authors:  Peter H Pennekamp; Markus A Wimmer; Lukas Eschbach; Björn Burian; Peter Koch; Clayton N Kraft
Journal:  J Mater Sci Mater Med       Date:  2007-06-09       Impact factor: 3.896

5.  Design of dental implants, influence on the osteogenesis and fixation.

Authors:  Luana M R Vasconcellos; Marize V Oliveira; Mário L A Graça; Luis G O Vasconcellos; Carlos A A Cairo; Yasmin R Carvalho
Journal:  J Mater Sci Mater Med       Date:  2008-03-18       Impact factor: 3.896

6.  Deposition of nano-hydroxyapatite particles utilising direct and transitional electrohydrodynamic processes.

Authors:  Z Ahmad; E S Thian; J Huang; M J Edirisinghe; S M Best; S N Jayasinghe; W Bonfield; R A Brooks; N Rushton
Journal:  J Mater Sci Mater Med       Date:  2008-04-05       Impact factor: 3.896

7.  Surface characterization and biological properties of regular dentin, demineralized dentin, and deproteinized dentin.

Authors:  Fahimeh Sadat Tabatabaei; Saeed Tatari; Ramin Samadi; Maryam Torshabi
Journal:  J Mater Sci Mater Med       Date:  2016-09-21       Impact factor: 3.896

8.  The Otto Aufranc Award: enhanced biocompatibility of stainless steel implants by titanium coating and microarc oxidation.

Authors:  Young Wook Lim; Soon Yong Kwon; Doo Hoon Sun; Yong Sik Kim
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

Review 9.  Influence of substratum surface chemistry/energy and topography on the human fetal osteoblastic cell line hFOB 1.19: Phenotypic and genotypic responses observed in vitro.

Authors:  Xiaomei Liu; Jung Yul Lim; Henry J Donahue; Ravi Dhurjati; Andrea M Mastro; Erwin A Vogler
Journal:  Biomaterials       Date:  2007-07-20       Impact factor: 12.479

10.  Surface Roughness and Biocompatibility of Polycaprolactone Bone Scaffolds: An Energy-Density-Guided Parameter Optimization for Selective Laser Sintering.

Authors:  Jian Han; Zehua Li; Yuxuan Sun; Fajun Cheng; Lei Zhu; Yaoyao Zhang; Zirui Zhang; Jinzhe Wu; Junfeng Wang
Journal:  Front Bioeng Biotechnol       Date:  2022-07-11
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.