Literature DB >> 3871572

Leg length determination by CT digital radiography.

A G Aitken, O Flodmark, D E Newman, R F Kilcoyne, W P Shuman, L A Mack.   

Abstract

CT digital radiography is a new accurate technique for measuring leg length discrepancy. It is easily performed on commercially available equipment with a radiation dose of 3-6 times less than the conventional technique. Because of the short time required to complete the examination, charges are comparable with those for existing procedures. Good correlation in total limb length measurements between this new technique and spot scanography was noted in 24 patients. CT digital radiography should be the preferred method for evaluation for limb length discrepancy, particularly in children, because of the simple technique and lowering of radiation dose.

Entities:  

Mesh:

Year:  1985        PMID: 3871572     DOI: 10.2214/ajr.144.3.613

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  Length and angle measurements of the lower extremity in digital composite overview images.

Authors:  M Boewer; H Arndt; P A W Ostermann; J Petersein; S Mutze
Journal:  Eur Radiol       Date:  2004-05-26       Impact factor: 5.315

2.  Three-dimensional measurements of the lower extremity in children and adolescents using a low-dose biplanar X-ray device.

Authors:  Ramon Gheno; Eric Nectoux; Bernard Herbaux; Matteo Baldisserotto; Luiz Glock; Anne Cotten; Nathalie Boutry
Journal:  Eur Radiol       Date:  2011-10-20       Impact factor: 5.315

3.  Leg length discrepancy in total hip arthroplasty: comparison of two methods of measurement.

Authors:  Arkan S Sayed-Noor; Anders Hugo; Göran O Sjödén; Per Wretenberg
Journal:  Int Orthop       Date:  2008-08-02       Impact factor: 3.075

4.  Methods for assessing leg length discrepancy.

Authors:  Sanjeev Sabharwal; Ajay Kumar
Journal:  Clin Orthop Relat Res       Date:  2008-10-04       Impact factor: 4.176

5.  Report on a new type of trauma full-body digital X-ray machine.

Authors:  S Beningfield; H Potgieter; A Nicol; S van As; G Bowie; E Hering; E Lätti
Journal:  Emerg Radiol       Date:  2003-04-09

Review 6.  Computed tomography for preoperative planning in total hip arthroplasty: what radiologists need to know.

Authors:  Alexander Huppertz; Sebastian Radmer; Moritz Wagner; Torsten Roessler; Bernd Hamm; Martin Sparmann
Journal:  Skeletal Radiol       Date:  2014-03-13       Impact factor: 2.199

7.  Leg length measures appear inaccurate in the early phase following total hip arthroplasty.

Authors:  Maria Anna Smolle; Stefan Franz Fischerauer; Michael Maier; Patrick Reinbacher; Jörg Friesenbichler; Paul Ruckenstuhl; Maria Grandesso; Andreas Leithner; Werner Maurer-Ertl
Journal:  Sci Rep       Date:  2021-12-01       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.