Literature DB >> 15290526

Report on a new type of trauma full-body digital X-ray machine.

S Beningfield1, H Potgieter, A Nicol, S van As, G Bowie, E Hering, E Lätti.   

Abstract

The purpose of this study was to evaluate the diagnostic equivalence, radiation dose, clinical usefulness and radiographic aspects of a low-dose, full-body digital X-ray machine in a busy trauma unit. A digital trauma X-ray machine known as "LODOX" was compared with conventional radiography between June 1999 and November 2001 in the Groote Schuur Hospital Trauma Unit, Cape Town. Digital images of a variety of body regions commonly imaged in trauma were compared for diagnostic image quality in a number of categories with equivalent conventional radiographs. A seven-point equivalence scoring system ranging from much inferior (-3) through equivalent (0) to much superior (+3) was used in each category. Radiation dose was recorded and compared with that in conventional measurements. Turnaround times of patients undergoing digital and conventional X-rays were evaluated. Clinical and radiographic issues were assessed by staff feedback. The digital images when compared with conventional film had an overall mean equivalence score of -0.429, with a standard deviation (SD) of 0.77. The best digital performance was in the mediastinum (mean 0.346, SD 0.49) and the weakest was for bony detail (mean -0.654, SD 0.81). Relative digital radiation dose compared to conventional varied from 72% (chest) to 2% (pelvis), with a simple average of 6%. Radiographic points included full-body imaging capability and differing positioning, penetration, workflow and practicality considerations. The digital images required overall patient times of 5-6 min, compared with 8-48 min for conventional X-rays. New installations are under way, and computed tomography and angiography applications are being explored. FDA approval is awaited. Projected cost is similar to that of flat-panel digital units. This digital unit was felt to be diagnostically substantially equivalent to conventional radiographs, with low-dose full-body imaging, improved workflow, digital technology and long-term cost benefits as potentially favourable contributions to trauma imaging.

Entities:  

Year:  2003        PMID: 15290526     DOI: 10.1007/s10140-003-0271-x

Source DB:  PubMed          Journal:  Emerg Radiol        ISSN: 1070-3004


  27 in total

1.  Comparison of digital and conventional musculoskeletal radiography: observer performance study.

Authors:  J M Bramble; M D Murphey
Journal:  Radiology       Date:  1990-11       Impact factor: 11.105

Review 2.  Digital skeletal radiography.

Authors:  K A Buckwalter; E M Braunstein
Journal:  AJR Am J Roentgenol       Date:  1992-05       Impact factor: 3.959

3.  Efficacy of digital radiography for the detection of pneumothorax: comparison with conventional chest radiography.

Authors:  E A Elam; K Rehm; B J Hillman; K Maloney; L L Fajardo; K McNeill
Journal:  AJR Am J Roentgenol       Date:  1992-03       Impact factor: 3.959

4.  Digital radiography in an intensive care unit.

Authors:  H Saito; T Kurashina; T Ishibashi; Y Shimanuki; K Sakamoto
Journal:  Clin Radiol       Date:  1988-03       Impact factor: 2.350

5.  Total digital radiology department: spatial resolution requirements.

Authors:  G W Seeley; H D Fisher; M O Stempski; M Borgstrom; J Bjelland; M P Capp
Journal:  AJR Am J Roentgenol       Date:  1987-02       Impact factor: 3.959

6.  Total digital radiology: is it feasible? Or desirable?

Authors:  J E Gray; P R Karsell; G P Becker; D G Gehring
Journal:  AJR Am J Roentgenol       Date:  1984-12       Impact factor: 3.959

7.  Single-slit digital radiography: some practical considerations.

Authors:  M M Tesic; R A Sones; D R Morgan
Journal:  AJR Am J Roentgenol       Date:  1984-04       Impact factor: 3.959

8.  Radiation dose reduction in the evaluation of scoliosis: an application of digital radiography.

Authors:  D C Kushner; R H Cleveland; T E Herman; D J Zaleske; M G Ehrlich; J A Correia
Journal:  Radiology       Date:  1986-10       Impact factor: 11.105

9.  Leg length determination by CT digital radiography.

Authors:  A G Aitken; O Flodmark; D E Newman; R F Kilcoyne; W P Shuman; L A Mack
Journal:  AJR Am J Roentgenol       Date:  1985-03       Impact factor: 3.959

10.  Low-dose flying spot digital radiography of the chest: sensitivity studies.

Authors:  D C Kushner; R H Cleveland; T E Herman; T C McLoud; A C Waltman; J A Shepard; C G Dedrick; D B Kopans; R E Greene
Journal:  Radiology       Date:  1987-06       Impact factor: 11.105

View more
  19 in total

1.  Three-dimensional point localisation in low-dose X-ray images using stereo-photogrammetry.

Authors:  T S Douglas; C L Vaughan; S M Wynne
Journal:  Med Biol Eng Comput       Date:  2004-01       Impact factor: 2.602

2.  MDCT diagnosis and endovascular management of bullet embolization to the heart.

Authors:  Joseph J Chen; Stuart E Mirvis; Kathirkama Shanmuganathan
Journal:  Emerg Radiol       Date:  2007-03-07

Review 3.  The use of the Statscan digital X-ray unit in paediatric polytrauma.

Authors:  Richard D Pitcher; Jim C H Wilde; Tania S Douglas; Arjan Bastiaan van As
Journal:  Pediatr Radiol       Date:  2008-12-09

Review 4.  Civilian gunshot injuries in orthopaedics: a narrative review of ballistics, current concepts, and the South African experience.

Authors:  Maritz Laubscher; Nando Ferreira; Franz Friedrich Birkholtz; Simon Matthew Graham; Sithombo Maqungo; Michael Held
Journal:  Eur J Orthop Surg Traumatol       Date:  2021-03-24

5.  Lodox®: the invaluable radiographic solution in the forensic setting.

Authors:  Marna du Plessis; Mandy Date-Chong; Linda Liebenberg
Journal:  Int J Legal Med       Date:  2019-07-10       Impact factor: 2.686

6.  Initial experience with Lodox Statscan imaging system for detecting injuries of the pelvis and appendicular skeleton.

Authors:  Michael E Mulligan; Christopher W Flye
Journal:  Emerg Radiol       Date:  2006-10-07

7.  Detection of urinary stones at reduced radiation exposure: a phantom study comparing computed radiography and a low-dose digital radiography linear slit scanning system.

Authors:  Zsolt Szucs-Farkas; Dev P Chakraborty; Harriet C Thoeny; Christos Loupatatzis; Peter Vock; Harald M Bonel
Journal:  AJR Am J Roentgenol       Date:  2009-06       Impact factor: 3.959

8.  Modeling, validation and application of a mathematical tissue-equivalent breast phantom for linear slot-scanning digital mammography.

Authors:  K Hussein; C L Vaughan; T S Douglas
Journal:  Phys Med Biol       Date:  2009-02-19       Impact factor: 3.609

9.  Paediatric dose measurement in a full-body digital radiography unit.

Authors:  Gert Johannes Maree; Benjamin John Irving; Egbert Raymond Hering
Journal:  Pediatr Radiol       Date:  2007-09-01

10.  Impact of computers in radiography: The advent of digital radiography, Part-2.

Authors:  Bs Verma; Ik Indrajit
Journal:  Indian J Radiol Imaging       Date:  2008-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.