Literature DB >> 3821477

Errors in T2 estimation using multislice multiple-echo imaging.

A P Crawley, R M Henkelman.   

Abstract

Accurate T2 images calculated from multiple-echo sequences are difficult to obtain over a number of contiguous slices due to the presence of unwanted echoes that are generated at the slice edges. This problem is similar to problems encountered in single-slice imaging in the presence of rf pulse imperfections. In this paper, we use computer simulations to show that all unwanted echoes can be eliminated by defocusing them using additions to the slice-selection gradients. Accurate T2 images may then be calculated from the remaining echoes. We also present a method of experimentally displaying the slice shapes of unwanted echoes generated by a multislice imaging sequence.

Mesh:

Year:  1987        PMID: 3821477     DOI: 10.1002/mrm.1910040105

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Recovery of Damped Exponentials Using Structured Low Rank Matrix Completion.

Authors:  Arvind Balachandrasekaran; Vincent Magnotta; Mathews Jacob
Journal:  IEEE Trans Med Imaging       Date:  2017-07-14       Impact factor: 10.048

2.  Fast radio-frequency enforced steady state (FRESS) spin echo MRI for quantitative T2 mapping: minimizing the apparent repetition time (TR) dependence for fast T2 measurement.

Authors:  Jerry S Cheung; Enfeng Wang; XiaoAn Zhang; Emiri Mandeville; Eng H Lo; A Gregory Sorensen; Phillip Zhe Sun
Journal:  NMR Biomed       Date:  2011-07-14       Impact factor: 4.044

Review 3.  Inferring brain tissue composition and microstructure via MR relaxometry.

Authors:  Mark D Does
Journal:  Neuroimage       Date:  2018-01-02       Impact factor: 6.556

4.  Fast T2 mapping with improved accuracy using undersampled spin-echo MRI and model-based reconstructions with a generating function.

Authors:  Tilman J Sumpf; Andreas Petrovic; Martin Uecker; Florian Knoll; Jens Frahm
Journal:  IEEE Trans Med Imaging       Date:  2014-12       Impact factor: 10.048

5.  Propagation of error from parameter constraints in quantitative MRI: Example application of multiple spin echo T2 mapping.

Authors:  Christopher L Lankford; Mark D Does
Journal:  Magn Reson Med       Date:  2017-04-20       Impact factor: 4.668

6.  Simultaneous measurement of T2 and apparent diffusion coefficient (T2 +ADC) in the heart with motion-compensated spin echo diffusion-weighted imaging.

Authors:  Eric Aliotta; Kévin Moulin; Zhaohuan Zhang; Daniel B Ennis
Journal:  Magn Reson Med       Date:  2017-05-17       Impact factor: 4.668

7.  Sensitivity-enhanced chemical exchange saturation transfer (CEST) MRI with least squares optimization of Carr Purcell Meiboom Gill multi-echo echo planar imaging.

Authors:  Phillip Zhe Sun; Yu Wang; Jie Lu
Journal:  Contrast Media Mol Imaging       Date:  2014 Mar-Apr       Impact factor: 3.161

8.  Rapid-motion-perception based cardiac navigators: using the high flow blood volume as a marker for the position of the heart.

Authors:  Vinay M Pai; Han Wen
Journal:  J Cardiovasc Magn Reson       Date:  2003       Impact factor: 5.364

9.  3 T MRI relaxometry detects T2 prolongation in the cerebral normal-appearing white matter in multiple sclerosis.

Authors:  Mohit Neema; Daniel Goldberg-Zimring; Zachary D Guss; Brian C Healy; Charles R G Guttmann; Maria K Houtchens; Howard L Weiner; Mark A Horsfield; David B Hackney; David C Alsop; Rohit Bakshi
Journal:  Neuroimage       Date:  2009-03-10       Impact factor: 6.556

10.  Rapid 3D radiofrequency field mapping using catalyzed double-angle method.

Authors:  Dingxin Wang; Sven Zuehlsdorff; Andrew C Larson
Journal:  NMR Biomed       Date:  2009-10       Impact factor: 4.044

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.