Literature DB >> 11219595

Enhanced methods for visualizing myocardial perfusion with peripheral venous injection of levovist: application of triggered harmonic imaging and triggered harmonic power Doppler imaging techniques.

K Hirooka1, K Miyatake, A Hanatani, K Komamura, S Nakatani, Y Yasumura, M Yamagishi.   

Abstract

OBJECTIVES: The purpose of this study was to determine whether triggered harmonic imaging (THI) or triggered harmonic power Doppler imaging (THPDI) could obtain the myocardial contrast enhancement using peripheral venous injection of a first generation echocardiographic contrast agent, Levovist.
METHODS: In a phantom model, we examined the influence of an acoustic power, harmonic filters, transmitted frequencies and focus positions of transducer on Levovist. Then fundamental, harmonic or harmonic power Doppler imaging were performed with ECG-triggered imaging in eight closed-chest dogs using bolus injection of Levovist.
RESULTS: In a phantom model, the highest transmission power (Mechanical index 1.6), a medium harmonic filter and a focus position (6 cm) resulted in the best enhanced contrast in both THI and THPDI. Furthermore, higher pulse repetition frequency (5500 Hz) of harmonic power Doppler made clearer enhancement. In animal models, we could not observe the apparent myocardial contrast using triggered fundamental imaging, and the intensity of each region of interest (ROI) of myocardium had not changed significantly. However, homogeneous myocardial contrast could be obtained using THI, which was conditioned on the highest transmission power, a medium harmonic filter same as the phantom model, at a lower transmitted frequency (1.8 MHz) and a focus position, which were located in the middle portion of the left ventricle. The peak intensity of each ROI increased significantly in a gray level. Furthermore, THPDI caused emphasized myocardial contrast visually.
CONCLUSIONS: These results indicate that THI and THPDI produce obvious MCE using peripheral venous injection of Levovist.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 11219595     DOI: 10.1023/a:1026592629450

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  37 in total

1.  Measurement of blood perfusion in tissue using Doppler ultrasound.

Authors:  S O Dymling; H W Persson; C H Hertz
Journal:  Ultrasound Med Biol       Date:  1991       Impact factor: 2.998

2.  Functional significance of collateral blood flow in patients with recent acute myocardial infarction. A study using myocardial contrast echocardiography.

Authors:  P J Sabia; E R Powers; A R Jayaweera; M Ragosta; S Kaul
Journal:  Circulation       Date:  1992-06       Impact factor: 29.690

3.  Safety and efficacy of a new transpulmonary ultrasound contrast agent: initial multicenter clinical results.

Authors:  S B Feinstein; J Cheirif; F J Ten Cate; P R Silverman; P A Heidenreich; C Dick; R M Desir; W F Armstrong; M A Quinones; P M Shah
Journal:  J Am Coll Cardiol       Date:  1990-08       Impact factor: 24.094

4.  Contrast echocardiography during coronary arteriography in humans: perfusion and anatomic studies.

Authors:  S B Feinstein; R M Lang; C Dick; A Neumann; J Al-Sadir; K G Chua; J Carroll; T Feldman; K M Borow
Journal:  J Am Coll Cardiol       Date:  1988-01       Impact factor: 24.094

5.  The development of harmonic distortion in pulsed finite-amplitude ultrasound passing through liver.

Authors:  H C Starritt; F A Duck; A J Hawkins; V F Humphrey
Journal:  Phys Med Biol       Date:  1986-12       Impact factor: 3.609

6.  Coronary collaterals assessed with myocardial contrast echocardiography in healed myocardial infarction.

Authors:  Y J Lim; S Nanto; T Masuyama; K Kodama; A Kohama; A Kitabatake; T Kamada
Journal:  Am J Cardiol       Date:  1990-09-01       Impact factor: 2.778

7.  Harmonic imaging with ultrasound contrast agents.

Authors:  P N Burns
Journal:  Clin Radiol       Date:  1996-02       Impact factor: 2.350

8.  Power versus conventional color Doppler sonography: comparison in the depiction of normal intrarenal vasculature.

Authors:  R O Bude; J M Rubin; R S Adler
Journal:  Radiology       Date:  1994-09       Impact factor: 11.105

9.  Detection of coronary artery disease with myocardial contrast echocardiography: comparison with 99mTc-sestamibi single-photon emission computed tomography.

Authors:  S Kaul; R Senior; H Dittrich; U Raval; R Khattar; A Lahiri
Journal:  Circulation       Date:  1997-08-05       Impact factor: 29.690

10.  Visualization of clear echocardiographic images with near field noise reduction technique: experimental study and clinical experience.

Authors:  T Hozumi; K Yoshida; Y Abe; R Kanda; T Akasaka; T Takagi; T Yagi; Y Ogata; J Yoshikawa
Journal:  J Am Soc Echocardiogr       Date:  1998-06       Impact factor: 5.251

View more
  2 in total

1.  A comparison of video and digital data in the assessment of myocardial perfusion abnormalities by myocardial contrast echocardiography.

Authors:  Hisashi Masugata; Kazushi Yukiiri; Yuichiro Takagi; Koji Ohmori; Katsufumi Mizushige; Masakazu Kohno
Journal:  Int J Cardiovasc Imaging       Date:  2004-06       Impact factor: 2.357

2.  Potential pitfalls of visualization of myocardial perfusion by myocardial contrast echocardiography with harmonic gray scale B-mode and power Doppler imaging.

Authors:  Hisashi Masugata; Kazushi Yukiiri; Yuichiro Takagi; Koji Ohmori; Katsufumi Mizushige; Masakazu Kohno
Journal:  Int J Cardiovasc Imaging       Date:  2004-04       Impact factor: 2.357

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.