Literature DB >> 23932276

Short-lag spatial coherence imaging of cardiac ultrasound data: initial clinical results.

Muyinatu A Lediju Bell1, Robi Goswami, Joseph A Kisslo, Jeremy J Dahl, Gregg E Trahey.   

Abstract

Short-lag spatial coherence (SLSC) imaging is a novel beamforming technique that reduces acoustic clutter in ultrasound images. A clinical study was conducted to investigate clutter reduction and endocardial border detection in cardiac SLSC images. Individual channel echo data were acquired from the left ventricle of 14 volunteers, after informed consent and institutional review board approval. Paired B-mode and SLSC images were created from these data. Contrast, contrast-to-noise, and signal-to-noise ratios were measured in paired images, and these metrics were improved with SLSC imaging in most cases. Three cardiology fellows rated the visibility of endocardial segments in randomly ordered B-mode and SLSC cine loops. SLSC imaging offered 22%-33% improvement (p < 0.05) in endocardial border visibility when B-mode image quality was poor (i.e., 80% or more of the endocardial segments could not be visualized by the three reviewers). The percentage of volunteers with poor-quality images was decreased from 21% to 7% with the SLSC beamformer. Results suggest that SLSC imaging has the potential to improve clinical cardiac assessments that are challenged by clutter. 2013 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved

Entities:  

Keywords:  B-mode; Clutter reduction; Coherence-based beamforming; Contrast; Echocardiography; Endocardial border detection; M-mode; Signal-to-noise ratio

Mesh:

Year:  2013        PMID: 23932276      PMCID: PMC3966558          DOI: 10.1016/j.ultrasmedbio.2013.03.029

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  38 in total

1.  Comparison of native and contrast-enhanced harmonic echocardiography for visualization of left ventricular endocardial border.

Authors:  J D Kasprzak; B Paelinck; F J Ten Cate; W B Vletter; N de Jong; D Poldermans; A Elhendy; A Bouakaz; J R Roelandt
Journal:  Am J Cardiol       Date:  1999-01-15       Impact factor: 2.778

Review 2.  Imaging techniques: Transoesophageal Echo-Doppler in cardiology.

Authors:  P Hanrath
Journal:  Heart       Date:  2001-11       Impact factor: 5.994

3.  Stationary clutter rejection in echocardiography.

Authors:  Gil Zwirn; Solange Akselrod
Journal:  Ultrasound Med Biol       Date:  2006-01       Impact factor: 2.998

4.  Estimation of left ventricular cavity area with an on-line, semiautomated echocardiographic edge detection system.

Authors:  B F Vandenberg; L S Rath; P Stuhlmuller; H E Melton; D J Skorton
Journal:  Circulation       Date:  1992-07       Impact factor: 29.690

5.  Impact of harmonic imaging on transthoracic echocardiographic identification of infective endocarditis and its complications.

Authors:  F Chirillo; A Pedrocco; A De Leo; A Bruni; O Totis; P Meneghetti; P Stritoni
Journal:  Heart       Date:  2005-03       Impact factor: 5.994

6.  Contrast-enhanced transthoracic second harmonic echo Doppler with adenosine: a noninvasive, rapid and effective method for coronary flow reserve assessment.

Authors:  C Caiati; N Zedda; C Montaldo; R Montisci; S Iliceto
Journal:  J Am Coll Cardiol       Date:  1999-07       Impact factor: 24.094

7.  The development of harmonic distortion in pulsed finite-amplitude ultrasound passing through liver.

Authors:  H C Starritt; F A Duck; A J Hawkins; V F Humphrey
Journal:  Phys Med Biol       Date:  1986-12       Impact factor: 3.609

8.  Reverberations in echocardiograms.

Authors:  E L Yeh
Journal:  J Clin Ultrasound       Date:  1977-04       Impact factor: 0.910

9.  Echocardiography in patients with suspected endocarditis: a cost-effectiveness analysis.

Authors:  P A Heidenreich; F A Masoudi; B Maini; T M Chou; E Foster; N B Schiller; D K Owens
Journal:  Am J Med       Date:  1999-09       Impact factor: 4.965

10.  Improved detection of left ventricular thrombi and spontaneous echocontrast by tissue harmonic imaging in patients with myocardial infarction.

Authors:  Donato Mele; Olga Soukhomovskaia; Emanuele Pacchioni; Elisa Merli; Nicola Avigni; Luca Federici; Robert A Levine; Roberto Ferrari
Journal:  J Am Soc Echocardiogr       Date:  2006-11       Impact factor: 5.251

View more
  24 in total

1.  Enhancing effect of phase coherence factor for improvement of spatial resolution in ultrasonic imaging.

Authors:  Hideyuki Hasegawa
Journal:  J Med Ultrason (2001)       Date:  2015-10-07       Impact factor: 1.314

2.  Robust Short-Lag Spatial Coherence Imaging of Breast Ultrasound Data: Initial Clinical Results.

Authors:  Alycen Wiacek; Ole Marius Hoel Rindal; Eniola Falomo; Kelly Myers; Kelly Fabrega-Foster; Susan Harvey; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-11-27       Impact factor: 2.725

3.  Short-lag spatial coherence beamforming of photoacoustic images for enhanced visualization of prostate brachytherapy seeds.

Authors:  Muyinatu A Lediju Bell; Nathanael Kuo; Danny Y Song; Emad M Boctor
Journal:  Biomed Opt Express       Date:  2013-09-04       Impact factor: 3.732

4.  In vivo visualization of prostate brachytherapy seeds with photoacoustic imaging.

Authors:  Muyinatu A Lediju Bell; Nathanael P Kuo; Danny Y Song; Jin U Kang; Emad M Boctor
Journal:  J Biomed Opt       Date:  2014-12       Impact factor: 3.170

5.  Initial phantom study on estimation of speed of sound in medium using coherence among received echo signals.

Authors:  Hideyuki Hasegawa; Ryo Nagaoka
Journal:  J Med Ultrason (2001)       Date:  2019-03-08       Impact factor: 1.314

6.  Angular coherence in ultrasound imaging: Theory and applications.

Authors:  You Leo Li; Jeremy J Dahl
Journal:  J Acoust Soc Am       Date:  2017-03       Impact factor: 1.840

7.  Improvement of performance of minimum variance beamformer by introducing cross covariance estimate.

Authors:  Hideyuki Hasegawa; Ryo Nagaoka
Journal:  J Med Ultrason (2001)       Date:  2020-02-20       Impact factor: 1.314

8.  Robust Short-Lag Spatial Coherence Imaging.

Authors:  Arun Asokan Nair; Trac Duy Tran; Muyinatu A Lediju Bell
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-03       Impact factor: 2.725

9.  Short-lag spatial coherence imaging on matrix arrays, part 1: Beamforming methods and simulation studies.

Authors:  Dongwoon Hyun; Gregg E Trahey; Marko Jakovljevic; Jeremy J Dahl
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-07       Impact factor: 2.725

10.  Clinical Utility of Fetal Short-Lag Spatial Coherence Imaging.

Authors:  Will Long; Dongwoon Hyun; Kingshuk Roy Choudhury; David Bradway; Patricia McNally; Brita Boyd; Sarah Ellestad; Gregg E Trahey
Journal:  Ultrasound Med Biol       Date:  2018-01-11       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.