Equivalent spectra as a measure of beam quality.

J M Boone.   

Abstract

The concept of the equivalent spectrum (Seq) is introduced, where Seq is defined as an idealized energy spectrum which results in identical attenuation properties as the actual spectrum of a given x-ray tube. Seq is described by two parameters, the equivalent aluminum filtration Aleq and the equivalent kilovoltage kVeq, which are evaluated iteratively using aluminum attenuation data. Published spectral data are used to demonstrate the merits of the equivalent spectrum technique, and experimental results are also presented. The technique is shown to be sensitive to changes in total filtration and, indirectly, to the waveform properties of the x-ray system. The use of the Seq may result in a better description of spectral properties for reporting purposes, and aid in standardizing radiographic techniques within an institution.

Entities:  

Mesh:

Year:  1986        PMID: 3796483     DOI: 10.1118/1.595811

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Development and validation of a measurement-based source model for kilovoltage cone-beam CT Monte Carlo dosimetry simulations.

Authors:  Kyle McMillan; Michael McNitt-Gray; Dan Ruan
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

2.  A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations.

Authors:  Adam C Turner; Di Zhang; Hyun J Kim; John J DeMarco; Chris H Cagnon; Erin Angel; Dianna D Cody; Donna M Stevens; Andrew N Primak; Cynthia H McCollough; Michael F McNitt-Gray
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

3.  Real-time dosimeter employed to evaluate the half-value layer in CT.

Authors:  Sarah E McKenney; J Anthony Seibert; George W Burkett; Dale Gelskey; Paul B Sunde; James D Newman; John M Boone
Journal:  Phys Med Biol       Date:  2013-12-19       Impact factor: 3.609

4.  Computer simulations and models for the performance characteristics of spectrally equivalent X-ray beams in medical diagnostic radiology.

Authors:  Akintunde A Okunade
Journal:  J Med Phys       Date:  2007-10

5.  Experimental implementation of a polyenergetic statistical reconstruction algorithm for a commercial fan-beam CT scanner.

Authors:  Joshua D Evans; Bruce R Whiting; David G Politte; Joseph A O'Sullivan; Paul F Klahr; Jeffrey F Williamson
Journal:  Phys Med       Date:  2013-01-21       Impact factor: 2.685

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.