Automated analysis of multiple performance characteristics in magnetic resonance imaging systems.

M M Covell, D O Hearshen, P L Carson, T P Chenevert, P Shreve, A M Aisen, F L Bookstein, B W Murphy, W Martel.   

Abstract

As with other digital imaging systems in heavy medical use, it is desirable with magnetic resonance imaging (MRI) to obtain extensive, rigorous system performance measures from a small set of images of one or two relatively simple test objects. Digital analysis of the parallel square rod (PSR) test object introduces digital image system self-evaluation to MRI and extends automated image evaluation to include rigorous measures throughout the imaging volume rather than just average measures over the image. Precise comparisons with theory and between systems can be performed as well as quality control and corrections for nonuniformities. The PSR test object consists of an 18 X 18 X 36 cm rectangular acrylic container enclosing 60 parallel square acrylic rods running the entire length. The inter-rod space is filled with a liquid or gel that produces strong, tissuelike signals in MRI and high contrast relative to the rods for computed tomography (CT). For profiles of slice thickness and separation, the rods are tilted in the test object to intersect the image plane at a 45 degree angle when the test object sides are parallel and perpendicular to the image plane. The test object itself is rotated 6-12 degrees about its major axis so that the sides of the rods make a small angle to the rows and columns of pixels. This allows digital sampling at finer spacing than the pixels for determination of edge response functions.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 3796477     DOI: 10.1118/1.595804

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Quality assurance of clinical MRI scanners using ACR MRI phantom: preliminary results.

Authors:  Chien-Chuan Chen; Yung-Liang Wan; Yau-Yau Wai; Ho-Ling Liu
Journal:  J Digit Imaging       Date:  2004-12       Impact factor: 4.056

2.  Assessment of mass properties of human head using various three-dimensional imaging modalities.

Authors:  K E Smith; G Bhatia; M W Vannier
Journal:  Med Biol Eng Comput       Date:  1995-05       Impact factor: 2.602

3.  Estimation and application of spatially variable noise fields in diffusion tensor imaging.

Authors:  Bennett A Landman; Pierre-Louis Bazin; Jerry L Prince
Journal:  Magn Reson Imaging       Date:  2009-02-28       Impact factor: 2.546

4.  Robust estimation of spatially variable noise fields.

Authors:  Bennett A Landman; Pierre-Louis Bazin; Seth A Smith; Jerry L Prince
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.