Consideration of spatially variable noise fields is becoming increasingly necessary in MRI given recent innovations in artifact identification and statistically driven image processing. Fast imaging methods enable study of difficult anatomical targets and improve image quality but also increase the spatial variability in the noise field. Traditional analysis techniques have either assumed that the noise is constant across the field of view (or region of interest) or have relied on separate MRI acquisitions to measure the noise field. These methods are either inappropriate for many modern scanning protocols or are overly time-consuming for already lengthy scanning sessions. We propose a new, general framework for estimating spatially variable noise fields from related, but independent MR scans that we call noise field equivalent scans. These heuristic analyses enable robust noise field estimation in the presence of artifacts. Generalization of noise estimators based on uniform regions, difference images, and maximum likelihood are presented and compared with the estimators derived from the proposed framework. Simulations of diffusion tensor imaging and T(2)-relaxometry demonstrate a 10-fold reduction in mean squared error in noise field estimation, and these improvements are shown to be robust to artifact contamination. In vivo studies show that spatially variable noise fields can be readily estimated with typical data acquired at 1.5T. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19526510      PMCID: PMC2806192          DOI: 10.1002/mrm.22013

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  23 in total

1.  Magnetization transfer in MRI: a review.

Authors:  R M Henkelman; G J Stanisz; S J Graham
Journal:  NMR Biomed       Date:  2001-04       Impact factor: 4.044

2.  A comparison of two methods for measuring the signal to noise ratio on MR images.

Authors:  M J Firbank; A Coulthard; R M Harrison; E D Williams
Journal:  Phys Med Biol       Date:  1999-12       Impact factor: 3.609

3.  Wavelet packet denoising of magnetic resonance images: importance of Rician noise at low SNR.

Authors:  J C Wood; K M Johnson
Journal:  Magn Reson Med       Date:  1999-03       Impact factor: 4.668

4.  Condition number as a measure of noise performance of diffusion tensor data acquisition schemes with MRI.

Authors:  S Skare; M Hedehus; M E Moseley; T Q Li
Journal:  J Magn Reson       Date:  2000-12       Impact factor: 2.229

Review 5.  Diffusion-tensor MRI: theory, experimental design and data analysis - a technical review.

Authors:  Peter J Basser; Derek K Jones
Journal:  NMR Biomed       Date:  2002 Nov-Dec       Impact factor: 4.044

Review 6.  Automatic estimation of the noise variance from the histogram of a magnetic resonance image.

Authors:  Jan Sijbers; Dirk Poot; Arnold J den Dekker; Wouter Pintjens
Journal:  Phys Med Biol       Date:  2007-02-08       Impact factor: 3.609

7.  Automatic detection of brain contours in MRI data sets.

Authors:  M E Brummer; R M Mersereau; R L Eisner; R J Lewine
Journal:  IEEE Trans Med Imaging       Date:  1993       Impact factor: 10.048

8.  Estimation of the noise in magnitude MR images.

Authors:  J Sijbers; A J den Dekker; J Van Audekerke; M Verhoye; D Van Dyck
Journal:  Magn Reson Imaging       Date:  1998       Impact factor: 2.546

9.  Measuring signal-to-noise ratios in MR imaging.

Authors:  L Kaufman; D M Kramer; L E Crooks; D A Ortendahl
Journal:  Radiology       Date:  1989-10       Impact factor: 11.105

10.  Signal-to-noise measures for magnetic resonance imagers.

Authors:  B W Murphy; P L Carson; J H Ellis; Y T Zhang; R J Hyde; T L Chenevert
Journal:  Magn Reson Imaging       Date:  1993       Impact factor: 2.546

View more
  12 in total

1.  Assessment of bias for MRI diffusion tensor imaging using SIMEX.

Authors:  Carolyn B Lauzon; Andrew J Asman; Ciprian Crainiceanu; Brian C Caffo; Bennett A Landman
Journal:  Med Image Comput Comput Assist Interv       Date:  2011

2.  Diffusion MRI noise mapping using random matrix theory.

Authors:  Jelle Veraart; Els Fieremans; Dmitry S Novikov
Journal:  Magn Reson Med       Date:  2015-11-24       Impact factor: 4.668

3.  Multi-parametric neuroimaging reproducibility: a 3-T resource study.

Authors:  Bennett A Landman; Alan J Huang; Aliya Gifford; Deepti S Vikram; Issel Anne L Lim; Jonathan A D Farrell; John A Bogovic; Jun Hua; Min Chen; Samson Jarso; Seth A Smith; Suresh Joel; Susumu Mori; James J Pekar; Peter B Barker; Jerry L Prince; Peter C M van Zijl
Journal:  Neuroimage       Date:  2010-11-20       Impact factor: 6.556

4.  Assessment of bias in experimentally measured diffusion tensor imaging parameters using SIMEX.

Authors:  Carolyn B Lauzon; Ciprian Crainiceanu; Brian C Caffo; Bennett A Landman
Journal:  Magn Reson Med       Date:  2012-05-18       Impact factor: 4.668

5.  A simple and fast adaptive nonlocal multispectral filtering algorithm for efficient noise reduction in magnetic resonance imaging.

Authors:  Mustapha Bouhrara; Michael C Maring; Richard G Spencer
Journal:  Magn Reson Imaging       Date:  2018-08-24       Impact factor: 2.546

6.  Signal-to-noise assessment for diffusion tensor imaging with single data set and validation using a difference image method with data from a multicenter study.

Authors:  Zhiyue J Wang; Jonathan M Chia; Shaheen Ahmed; Nancy K Rollins
Journal:  Med Phys       Date:  2014-09       Impact factor: 4.071

7.  A fast algorithm for denoising magnitude diffusion-weighted images with rank and edge constraints.

Authors:  Fan Lam; Ding Liu; Zhuang Song; Norbert Schuff; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2015-03-02       Impact factor: 4.668

8.  Optimization of 7-T chemical exchange saturation transfer parameters for validation of glycosaminoglycan and amide proton transfer of fibroglandular breast tissue.

Authors:  Adrienne N Dula; Blake E Dewey; Lori R Arlinghaus; Jason M Williams; Dennis Klomp; Thomas E Yankeelov; Seth Smith
Journal:  Radiology       Date:  2014-10-29       Impact factor: 11.105

9.  Denoising diffusion-weighted magnitude MR images using rank and edge constraints.

Authors:  Fan Lam; S Derin Babacan; Justin P Haldar; Michael W Weiner; Norbert Schuff; Zhi-Pei Liang
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

10.  Correcting power and p-value calculations for bias in diffusion tensor imaging.

Authors:  Carolyn B Lauzon; Bennett A Landman
Journal:  Magn Reson Imaging       Date:  2013-03-05       Impact factor: 2.546

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.