Literature DB >> 3760377

Comparative study of coronary flow reserve, coronary anatomy and results of radionuclide exercise tests in patients with coronary artery disease.

V Legrand, G B Mancini, E R Bates, J M Hodgson, M D Gross, R A Vogel.   

Abstract

A comparative assessment of regional coronary flow reserve, quantitative percent diameter coronary stenosis and exercise-induced perfusion and wall motion abnormalities was performed in 39 patients with coronary artery disease. Coronary flow reserve was determined by a digital angiographic technique utilizing contrast medium as the hyperemic agent. Percent diameter stenosis was calculated by an automated quantification program applied to orthogonal cineangiograms. Thallium-201 scintigraphy and radionuclide ventriculography were used to assess regional perfusion and wall motion abnormalities, respectively, at rest and during exercise. In Group A, 19 patients without transmural infarction or collateral vessels, coronary flow reserve was inversely related to percent diameter stenosis (r = -0.61, p less than 0.0001), and scintigraphic abnormalities occurred only in vascular distributions with a coronary flow reserve of less than 2.00. There was a strong relation among abnormal regional exercise results, stenoses greater than 50% and reactive hyperemia of less than 2.00. Patients with multivessel disease, however, often had normal exercise scintigrams in regions associated with greater than 50% stenosis and low coronary flow reserve when other regions had a lower coronary flow reserve or higher grade stenosis, or both. In Group B, 20 patients with angiographically visible collateral vessels, 12 of whom had prior myocardial infarction, coronary flow reserve correlated less well with percent diameter stenosis than in Group A (r = -0.47, p less than 0.004). As in Group A patients, there was a significant relation between abnormal exercise test results and stenoses greater than 50%. However, reactive hyperemia values were generally lower than in Group A, and positive exercise stress results were strongly correlated only with highly impaired flow reserves of 1.3 or less. In Group B patients, the coronary flow reserve of vessels with less than 50% stenosis was significantly lower than that of similar vessels in Group A patients (2.40 +/- 0.79 versus 1.56 +/- 0.43; p less than 0.0002). It is concluded that: there is a general relation between quantitative percent diameter stenosis and reactive hyperemia that is not of sufficient precision to allow accurate prediction of coronary flow reserve in individual cases; exercise scintigraphic abnormalities are usually associated with low coronary flow reserve, and the relation between these two functional tests is stronger than the relation between exercise test results and quantitative percent diameter stenosis.(ABSTRACT TRUNCATED AT 400 WORDS)

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3760377     DOI: 10.1016/s0735-1097(86)80377-1

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

Review 1.  Are separate normal data files required for quantitative pharmacologic stress radionuclide myocardial perfusion imaging?

Authors:  F J Wackers
Journal:  J Nucl Cardiol       Date:  1996 Nov-Dec       Impact factor: 5.952

2.  Correlations between quantitative cineangiography, coronary flow reserve measured with digital subtraction cineangiography and exercise thallium perfusion scintigraphy.

Authors:  F Zijlstra; P Fioretti; J H Reiber; P W Serruys
Journal:  Int J Card Imaging       Date:  1988

3.  Comparison of transesophageal Doppler coronary flow reserve measurements with thallium-201 single-photon emission computed tomography imaging in assessment of left anterior descending artery stenoses.

Authors:  M Zehetgruber; D Mörtl; G Porenta; G Mundigler; G Christ; R Lengauer; G Stix; P Probst; G Maurer; H Sochor; P Siostrzonek
Journal:  Clin Cardiol       Date:  1998-04       Impact factor: 2.882

4.  Validation in the canine model of a new non-invasive method of measuring coronary blood flow reserve: split dose thallium-201 rest/stress imaging.

Authors:  J A Diamond; J Machac; S Vallabhajosula; M J Henzlova; M K Ali; C K Mezrow; A Gandses; A Travis; R A Phillips
Journal:  Int J Cardiovasc Imaging       Date:  2001-04       Impact factor: 2.357

Review 5.  PET and SPECT in heart failure.

Authors:  Christoph Rischpler; Stephan Nekolla; Markus Schwaiger
Journal:  Curr Cardiol Rep       Date:  2013-03       Impact factor: 2.931

6.  Transcatheter coronary artery diagnostic techniques including impedance-catheter and impedance-guidewire measurement of absolute coronary blood flow.

Authors:  R A Vogel; L W Martin
Journal:  Tex Heart Inst J       Date:  1989

7.  Endogenous murine microbiota member Faecalibaculum rodentium and its human homologue protect from intestinal tumour growth.

Authors:  Elena Zagato; Chiara Pozzi; Alice Bertocchi; Tiziana Schioppa; Fabiana Saccheri; Silvia Guglietta; Bruno Fosso; Laura Melocchi; Giulia Nizzoli; Jacopo Troisi; Marinella Marzano; Bianca Oresta; Ilaria Spadoni; Koji Atarashi; Sara Carloni; Stefania Arioli; Giulia Fornasa; Francesco Asnicar; Nicola Segata; Simone Guglielmetti; Kenya Honda; Graziano Pesole; William Vermi; Giuseppe Penna; Maria Rescigno
Journal:  Nat Microbiol       Date:  2020-01-27       Impact factor: 17.745

8.  The enigmatic SAR202 cluster up close: shedding light on a globally distributed dark ocean lineage involved in sulfur cycling.

Authors:  Maliheh Mehrshad; Francisco Rodriguez-Valera; Mohammad Ali Amoozegar; Purificación López-García; Rohit Ghai
Journal:  ISME J       Date:  2017-12-05       Impact factor: 10.302

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.