Literature DB >> 9562934

Comparison of transesophageal Doppler coronary flow reserve measurements with thallium-201 single-photon emission computed tomography imaging in assessment of left anterior descending artery stenoses.

M Zehetgruber1, D Mörtl, G Porenta, G Mundigler, G Christ, R Lengauer, G Stix, P Probst, G Maurer, H Sochor, P Siostrzonek.   

Abstract

BACKGROUND AND HYPOTHESIS: Recent studies demonstrate the feasibility of coronary flow reserve measurements by transesophageal echocardiographic (TEE) Doppler recordings of coronary sinus or left anterior descending (LAD) coronary artery flow velocity for detecting stenoses of the LAD artery. This study compares coronary flow reserve measurements by Doppler TEE with thallium-201 (201Tl) single-photon emission computed tomography (SPECT) in patients with proximal single-vessel LAD stenosis.
METHODS: Nineteen patients with various degrees of LAD stenosis (mean area stenosis 71 +/- 24%; range 24-96%) were studied. Area stenosis by quantitative coronary angiography was < 75% in 7 patients and > 75% in 12 patients. Transesophageal LAD and coronary sinus Doppler measurements were performed at baseline and after intravenous dipyridamole. Coronary flow reserve was calculated as the ratio of hyperemic to baseline average peak velocities. Predefined coronary flow reserve cut-off values of 1.8 for the coronary sinus method and of 2.0 for the LAD method were used for diagnosis of significant LAD stenosis. Results were compared with qualitative 201Tl dipyridamole SPECT.
RESULTS: Overall predictive accuracy for diagnosis of > 75% LAD stenosis was 79% for 201Tl SPECT, 77% for the transesophageal LAD and 79% for the transesophageal coronary sinus technique. Concordant results between 201Tl SPECT and the LAD and coronary sinus Doppler methods were observed in 79% and 71% of patients, respectively.
CONCLUSIONS: Thallium-201 SPECT and transesophageal Doppler assessment of coronary flow reserve have similar accuracy for diagnosing significant proximal LAD stenosis. Therefore, both transesophageal Doppler techniques might constitute another widely available, noninvasive method for assessment of left coronary artery disease, if disease location is proximal.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9562934      PMCID: PMC6655278          DOI: 10.1002/clc.4960210404

Source DB:  PubMed          Journal:  Clin Cardiol        ISSN: 0160-9289            Impact factor:   2.882


  21 in total

Review 1.  Limitations of coronary angiography: an underestimated problem?

Authors:  D Katritsis; M Webb-Peploe
Journal:  Clin Cardiol       Date:  1991-01       Impact factor: 2.882

Review 2.  Exercise thallium-201 perfusion scintigraphy in the assessment of coronary artery disease.

Authors:  J J Mahmarian; M S Verani
Journal:  Am J Cardiol       Date:  1991-05-21       Impact factor: 2.778

3.  Validation of a Doppler guide wire for intravascular measurement of coronary artery flow velocity.

Authors:  J W Doucette; P D Corl; H M Payne; A E Flynn; M Goto; M Nassi; J Segal
Journal:  Circulation       Date:  1992-05       Impact factor: 29.690

4.  Comparison of coronary vasodilation with intravenous dipyridamole and adenosine.

Authors:  J D Rossen; J E Quillen; A G Lopez; R G Stenberg; C L Talman; M D Winniford
Journal:  J Am Coll Cardiol       Date:  1991-08       Impact factor: 24.094

5.  The significance of coronary reserve in clinical heart disease.

Authors:  B E Strauer
Journal:  J Am Coll Cardiol       Date:  1990-03-15       Impact factor: 24.094

Review 6.  Methods of measuring myocardial blood flow in humans.

Authors:  C W White; R F Wilson; M L Marcus
Journal:  Prog Cardiovasc Dis       Date:  1988 Sep-Oct       Impact factor: 8.194

7.  Measurements of coronary velocity and reactive hyperemia in the coronary circulation of humans.

Authors:  M Marcus; C Wright; D Doty; C Eastham; D Laughlin; P Krumm; C Fastenow; M Brody
Journal:  Circ Res       Date:  1981-10       Impact factor: 17.367

8.  Comparative study of coronary flow reserve, coronary anatomy and results of radionuclide exercise tests in patients with coronary artery disease.

Authors:  V Legrand; G B Mancini; E R Bates; J M Hodgson; M D Gross; R A Vogel
Journal:  J Am Coll Cardiol       Date:  1986-11       Impact factor: 24.094

9.  Comparison of maximal myocardial blood flow during adenosine infusion with that of intravenous dipyridamole in normal men.

Authors:  S Y Chan; R C Brunken; J Czernin; G Porenta; W Kuhle; J Krivokapich; M E Phelps; H R Schelbert
Journal:  J Am Coll Cardiol       Date:  1992-10       Impact factor: 24.094

10.  Transesophageal Doppler echocardiography evaluation of coronary blood flow velocity in baseline conditions and during dipyridamole-induced coronary vasodilation.

Authors:  S Iliceto; V Marangelli; C Memmola; P Rizzon
Journal:  Circulation       Date:  1991-01       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.