Literature DB >> 3049845

Correlations between quantitative cineangiography, coronary flow reserve measured with digital subtraction cineangiography and exercise thallium perfusion scintigraphy.

F Zijlstra1, P Fioretti, J H Reiber, P W Serruys.   

Abstract

The goal of this investigation was to establish which anatomical parameters of stenotic lesions correlate best with its functional severity. Therefore, thirty-eight patients with single vessel disease underwent coronary cineangiography and exercise/redistribution thallium-201 scintigraphy. Cross-sectional area at the site of obstruction (OA), percentage diameter stenosis (DS), the calculated pressuredrop over the stenosis (PD), as well as coronary flow reserve (CFR) derived from myocardial contrast appearance time and density were determined. The relations between CFR and the 3 anatomical parameters were described by the following equations: CFR = 4.6 - 0.053 DS, r = 0.82, SEE: 0.79, p less than 0.001 CFR = 0.5 + 0.75 OA, r = 0.87, SEE: 0.68, p less than 0.001 CFR = 3.6 - 1.5 log PD, r = 0.90, SEE: 0.62, p less than 0.001 The calculated pressuredrop was highly predictive of the thallium scintigraphic results with a sensitivity of 94% and a specificity of 90%. Therefore, the calculated pressuredrop is a better anatomical parameter for assessing the functional importance of a stenosis than percentage diameter stenosis or obstruction area. However, the 95% confidence limits of the relation between pressuredrop and coronary flow reserve are wide, making measurement of CFR a valuable addition to quantitative angiography, especially when determining the functional importance of moderately severe coronary artery lesions.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3049845     DOI: 10.1007/BF01814886

Source DB:  PubMed          Journal:  Int J Card Imaging        ISSN: 0167-9899


  18 in total

1.  The radiographic assessment of coronary blood flow parameters.

Authors:  R A Vogel
Journal:  Circulation       Date:  1985-09       Impact factor: 29.690

Review 2.  Thallium-201 myocardial scintigraphy.

Authors:  A S Iskandrian; A H Hakki
Journal:  Am Heart J       Date:  1985-01       Impact factor: 4.749

3.  Physiologic basis for assessing critical coronary stenosis. Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve.

Authors:  K L Gould; K Lipscomb; G W Hamilton
Journal:  Am J Cardiol       Date:  1974-01       Impact factor: 2.778

4.  Does the quantitative assessment of coronary artery dimensions predict the physiologic significance of a coronary stenosis?

Authors:  F Zijlstra; J van Ommeren; J H Reiber; P W Serruys
Journal:  Circulation       Date:  1987-06       Impact factor: 29.690

5.  Assessment of short-, medium-, and long-term variations in arterial dimensions from computer-assisted quantitation of coronary cineangiograms.

Authors:  J H Reiber; P W Serruys; C J Kooijman; W Wijns; C J Slager; J J Gerbrands; J C Schuurbiers; A den Boer; P G Hugenholtz
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

6.  Experimental validation of quantitative coronary arteriography for determining pressure-flow characteristics of coronary stenosis.

Authors:  K L Gould; K O Kelley; E L Bolson
Journal:  Circulation       Date:  1982-11       Impact factor: 29.690

7.  Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis?

Authors:  C W White; C B Wright; D B Doty; L F Hiratza; C L Eastham; D G Harrison; M L Marcus
Journal:  N Engl J Med       Date:  1984-03-29       Impact factor: 91.245

8.  Assessment of coronary stenoses by myocardial perfusion imaging during pharmacologic coronary vasodilation. VII. Validation of coronary flow reserve as a single integrated functional measure of stenosis severity reflecting all its geometric dimensions.

Authors:  R L Kirkeeide; K L Gould; L Parsel
Journal:  J Am Coll Cardiol       Date:  1986-01       Impact factor: 24.094

9.  Assessment of dimensions and image quality of coronary contrast catheters from cineangiograms.

Authors:  J H Reiber; C J Kooijman; A den Boer; P W Serruys
Journal:  Cathet Cardiovasc Diagn       Date:  1985

10.  Quantitative angiography of the left anterior descending coronary artery: correlations with pressure gradient and results of exercise thallium scintigraphy.

Authors:  W Wijns; P W Serruys; J H Reiber; M van den Brand; M L Simoons; C J Kooijman; K Balakumaran; P G Hugenholtz
Journal:  Circulation       Date:  1985-02       Impact factor: 29.690

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.