Literature DB >> 7252561

Spatial and temporal quantitation of plane thallium myocardial images.

D D Watson, N P Campbell, E K Read, R S Gibson, C D Teates, G A Beller.   

Abstract

A computer method has been developed to determine the relative initial uptake and segmental washout rates of thallium-201 from sequential myocardial images. Initial images in multiple projections are obtained at 10 min after thallium-201 injection, and delayed images 2-3 hr after injection. A modified interpolative method was used to construct a background reference plane, and net myocardial counts was used to construct a background reference plane, and net myocardial counts above this reference plane were determined from multiple count profiles. Washout rates were determined by linear regression of time-activity curves constructed from the sequential images. In this approach, both relative temporal as well as relative spatial quantitation is performed. Data from 25 normal subjects were used to establish numerical criteria and normal ranges for relative focal defects and abnormal segmental washout slopes. Normal ranges were set to include the 90-percentile limits of the distribution of values obtained from the normal population. From these values we derived a quantitative criterion for thallium scan interpretation that can be used for analysis and interpretation of scintigrams in clinical situations.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7252561

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  29 in total

Review 1.  Advances in quantitative perfusion SPECT imaging.

Authors:  Edward P Ficaro; James R Corbett
Journal:  J Nucl Cardiol       Date:  2004 Jan-Feb       Impact factor: 5.952

Review 2.  The use of computer-assisted diagnosis in cardiac-perfusion nuclear medicine studies: a review.

Authors:  F L Datz; F V Gabor; P E Christian; G T Gullberg; C E Menzel; K A Morton
Journal:  J Digit Imaging       Date:  1992-11       Impact factor: 4.056

Review 3.  Quantitative analysis in single photon emission tomography (SPET).

Authors:  K A Blokland; H H Reiber; E K Pauwels
Journal:  Eur J Nucl Med       Date:  1992

Review 4.  Myocardial perfusion scintigraphy: past, present and future.

Authors:  A Notghi; C S Low
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

5.  Tl-201 washout rate in remote normal regions in patients with prior myocardial infarction and left ventricular remodeling.

Authors:  Toshihiko Goto; Nobuyuki Ohte; Hiromichi Miyabe; Seiji Mukai; Seiichiro Sakata; Junichiro Hayano; Genjiro Kimura
Journal:  J Nucl Cardiol       Date:  2005 Mar-Apr       Impact factor: 5.952

6.  Myocardial perfusion and function single photon emission computed tomography.

Authors:  Christopher L Hansen; Richard A Goldstein; Daniel S Berman; Keith B Churchwell; C David Cooke; James R Corbett; S James Cullom; Seth T Dahlberg; James R Galt; Ravi K Garg; Gary V Heller; Mark C Hyun; Lynne L Johnson; April Mann; Benjamin D McCallister; Raymond Taillefer; R Parker Ward; John J Mahmarian
Journal:  J Nucl Cardiol       Date:  2006-11       Impact factor: 5.952

7.  Quantitative nuclear cardiology and future directions for SPECT imaging.

Authors:  George A Beller
Journal:  J Nucl Cardiol       Date:  2007-07       Impact factor: 5.952

Review 8.  Science, art, and artifacts: how important is quantification for the practicing physician interpreting myocardial perfusion studies?

Authors:  F J Wackers
Journal:  J Nucl Cardiol       Date:  1994 Sep-Oct       Impact factor: 5.952

9.  Imaging guidelines for nuclear cardiology procedures. American Society of Nuclear Cardiology. Myocardial perfusion planar protocols.

Authors: 
Journal:  J Nucl Cardiol       Date:  1996 May-Jun       Impact factor: 5.952

10.  Exercise testing with myocardial perfusion imaging in patients with normal baseline electrocardiograms: cost savings with a stepwise diagnostic strategy.

Authors:  J A Mattera; S A Arain; A J Sinusas; L Finta; F J Wackers
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.