Literature DB >> 3669950

Reducing motion artifacts in two-dimensional Fourier transform imaging.

E M Haacke1, J L Patrick.   

Abstract

The effects of motion in two-dimensional Fourier transform imaging (2DFT) are considered. Specific calculations describing the case of periodic motion are presented. The results predict the commonly seen artifact of image replication, sometimes referred to as ghosting. Expressions for both position and amplitude of these ghosts are derived. Simulated examples illustrate the image degradation for pulsatile flow and in plane motion. Several methods of reducing motion artifacts are then suggested. These include: randomization of views, averaging views, matching repeat times to the respiratory period, hybrid imaging, ROPE and COPE. The latter two methods reorder the data acquisition to destroy the coherence of the motion. They do not increase the data acquisition time and promise to be part of the standard approach to remove motion artifacts. The final step in actually recovering ideal resolution can be accomplished by using a model of the motion and a generalized transform inversion technique.

Mesh:

Year:  1986        PMID: 3669950     DOI: 10.1016/0730-725x(86)91046-5

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  27 in total

1.  MR CAT scan: a modular approach for hybrid imaging.

Authors:  C Hillenbrand; D Hahn; A Haase; P M Jakob
Journal:  MAGMA       Date:  2000-07       Impact factor: 2.310

Review 2.  Motion-compensation techniques in neonatal and fetal MR imaging.

Authors:  C Malamateniou; S J Malik; S J Counsell; J M Allsop; A K McGuinness; T Hayat; K Broadhouse; R G Nunes; A M Ederies; J V Hajnal; M A Rutherford
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-10       Impact factor: 3.825

Review 3.  Body MR Imaging: Artifacts, k-Space, and Solutions.

Authors:  Susie Y Huang; Ravi T Seethamraju; Pritesh Patel; Peter F Hahn; John E Kirsch; Alexander R Guimaraes
Journal:  Radiographics       Date:  2015-07-24       Impact factor: 5.333

4.  A multifunction digital receiver suitable for real-time frequency detection and compensation in fast magnetic resonance imaging.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2019-05       Impact factor: 1.523

Review 5.  Will MRI of gastrointestinal function parallel the clinical success of cine cardiac MRI?

Authors:  Caroline Hoad; Christopher Clarke; Luca Marciani; Martin John Graves; Maura Corsetti
Journal:  Br J Radiol       Date:  2018-10-24       Impact factor: 3.039

6.  Evaluation of 3D fat-navigator based retrospective motion correction in the clinical setting of patients with brain tumors.

Authors:  Carl Glessgen; Daniel Gallichan; Manuela Moor; Nicolin Hainc; Christian Federau
Journal:  Neuroradiology       Date:  2019-01-23       Impact factor: 2.804

7.  Parallel 2D FFT implementation on FPGA suitable for real-time MR image processing.

Authors:  Limin Li; Alice M Wyrwicz
Journal:  Rev Sci Instrum       Date:  2018-09       Impact factor: 1.523

8.  4D micro-CT using fast prospective gating.

Authors:  Xiaolian Guo; Samuel M Johnston; Yi Qi; G Allan Johnson; Cristian T Badea
Journal:  Phys Med Biol       Date:  2012-01-07       Impact factor: 3.609

Review 9.  Motion correction in MRI of the brain.

Authors:  F Godenschweger; U Kägebein; D Stucht; U Yarach; A Sciarra; R Yakupov; F Lüsebrink; P Schulze; O Speck
Journal:  Phys Med Biol       Date:  2016-02-11       Impact factor: 3.609

10.  An MRI-compatible platform for one-dimensional motion management studies in MRI.

Authors:  Joris Nofiele; Qing Yuan; Mohammad Kazem; Ken Tatebe; Quinn Torres; Amit Sawant; Ivan Pedrosa; Rajiv Chopra
Journal:  Magn Reson Med       Date:  2015-10-23       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.