Literature DB >> 3616751

A morphometric study of human lumbar and selected thoracic vertebrae.

J L Berry, J M Moran, W S Berg, A D Steffee.   

Abstract

The results of a morphometric study of selected human vertebrae undertaken to provide data for implant design are presented in this report. Twenty-seven dimensions were measured from thoracic (T2, T7, T12) and lumbar (L1-L5) vertebrae using prepared spinal columns from 30 skeletons belonging to the Hamann-Todd Osteological Collection. Maximum and minimum pedicle dimensions indicated that the pedicles are less symmetric cephalad than they are caudal. Vertebral body height increases caudally except posteriorly where, after an initial increase, it decreases in the lower lumbar region. Major and minor body diameters and the major spinal canal diameter slightly increase caudally, whereas minor spinal canal diameter exhibits little or no change.

Entities:  

Mesh:

Year:  1987        PMID: 3616751     DOI: 10.1097/00007632-198705000-00010

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  48 in total

1.  Biomechanical evaluation of a bipedicular spinal fixation device: three different strength tests.

Authors:  Laurent Balabaud; Emeric Gallard; Wafa Skalli; Bernard Dupas; Robert Roger; François Lavaste; Jean-Paul Steib
Journal:  Eur Spine J       Date:  2003-04-05       Impact factor: 3.134

2.  Measurements of the lumbar pedicles in the Eastern Anatolian population.

Authors:  H H Kadioglu; E Takci; A Levent; M Arik; I H Aydin
Journal:  Surg Radiol Anat       Date:  2003-05-14       Impact factor: 1.246

3.  Analysis of lumbar pedicle morphology in degenerative spines using multiplanar reconstruction computed tomography: what can be the reliable index for optimal pedicle screw diameter?

Authors:  Takahiro Makino; Takashi Kaito; Hiroyasu Fujiwara; Kazuo Yonenobu
Journal:  Eur Spine J       Date:  2012-02-19       Impact factor: 3.134

4.  A morphological study of lumbar vertebral endplates: radiographic, visual and digital measurements.

Authors:  Yue Wang; Michele C Battié; Tapio Videman
Journal:  Eur Spine J       Date:  2012-06-29       Impact factor: 3.134

5.  Current issues with standards in the measurement and documentation of human skeletal anatomy.

Authors:  Justin Magee; Brian McClelland; John Winder
Journal:  J Anat       Date:  2012-07-02       Impact factor: 2.610

6.  Comparison of radiographic and computed tomographic measurement of pedicle and vertebral body dimensions in Koreans: the ratio of pedicle transverse diameter to vertebral body transverse diameter.

Authors:  Ki Ser Kang; Kwang-Sup Song; Jong Seok Lee; Jae Jun Yang; In Sup Song
Journal:  Eur Spine J       Date:  2010-08-30       Impact factor: 3.134

7.  Morphometry of the lower lumbar intervertebral discs and endplates: comparative analyses of new MRI data with previous findings.

Authors:  Ruoliang Tang; Celal Gungor; Richard F Sesek; Kenneth Bo Foreman; Sean Gallagher; Gerard A Davis
Journal:  Eur Spine J       Date:  2016-02-12       Impact factor: 3.134

8.  Comparison of pullout strength of the thoracic pedicle screw between intrapedicular and extrapedicular technique: a meta-analysis and literature review.

Authors:  Hua Wang; Huafeng Wang; Shilabant Sen Sribastav; Fubiao Ye; Chunxiang Liang; Zemin Li; Jianru Wang; Hui Liu; Xin Wang; Zhaomin Zheng
Journal:  Int J Clin Exp Med       Date:  2015-12-15

9.  A preliminary study of reliability of impedance measurement to detect iatrogenic initial pedicle perforation (in the porcine model).

Authors:  Ciaran Bolger; C Carozzo; T Roger; Linda McEvoy; Jabir Nagaria; Gerard Vanacker; Maurice Bourlion
Journal:  Eur Spine J       Date:  2005-10-13       Impact factor: 3.134

Review 10.  [Surgical anatomy of the lumbar spine].

Authors:  R E Willburger; J Krämer; M Wiese
Journal:  Orthopade       Date:  2005-10       Impact factor: 1.087

View more