| Literature DB >> 36160094 |
Cynthia C Jiang1, Noah M Hodson1, Daniel A Johnson1, Ahmad Kheirkhah1.
Abstract
Purpose: To compare the accuracy of various intraocular lens power formulas for two monofocal hydrophobic foldable lenses, the AcrySof SN60WF and the Tecnis ZCB00.Entities:
Keywords: Intraocular Lens; SN60WF; ZCB00; Formula Accuracy
Year: 2022 PMID: 36160094 PMCID: PMC9493430 DOI: 10.18502/jovr.v17i3.11571
Source DB: PubMed Journal: J Ophthalmic Vis Res ISSN: 2008-322X
Patient demographics and ocular biometric values for eyes with SN60WF and ZCB00 lenses.
|
| |||
|
| |||
| Age (yr) | 70.71 | 70.41 | 0.57 |
| Sex (F/M) | 178/121 | 75/35 | 0.14 |
| IOL power used in surgery (D) | 20.31 | 20.59 | 0.46 |
| Axial length (mm) | 23.85 | 23.90 | 0.74 |
| Lens thickness (mm) | 4.61 | 4.57 | 0.38 |
| Anterior chamber depth (ACD) | 3.12 | 3.17 | 0.25 |
| White-to-white diameter (mm) | 11.97 | 12.00 | 0.35 |
| Mean keratometry (D) | 43.88 | 43.76 | 0.48 |
| Postoperative refraction (D) | –0.17 | –0.01 | 0.02 |
Mean absolute error (MAE) and mean numerical error (MNE) for each formula for both SN60WF and ZCB00 lenses.
|
| ||||||
|
|
| |||||
| Barrett Universal II | 0.41 | 0.42 | 0.94 | 0.21 | 0.28 | 0.21 |
| Haigis | 0.42 | 0.46 | 0.24 | 0.14 | 0.20 | 0.30 |
| Hoffer-Q | 0.44 | 0.48 | 0.43 | 0.15 | 0.29 | 0.04 |
| Holladay 2 | 0.42 | 0.41 | 0.69 | 0.09 | 0.18 | 0.23 |
| SRK/T | 0.49 | 0.49 | 0.66 | 0.15 | 0.31 | 0.07 |
|
| 0.27 | 0.002 |
|
| ||
Percentage of eyes within 0.25 D, 0.5 D, 1.0 D, and 2.0 D of the predicted refraction for both SN60WF and ZCB00 lenses.
|
| ||||||||
| Barrett Universal II | 40.8% | 70.6% | 93.0% | 99.7% | 40.9% | 68.2% | 91.8% | 100.0% |
| Haigis | 41.5% | 66.9% | 91.6% | 99.3% | 39.1% | 64.6% | 89.1% | 100.0% |
| Hoffer-Q | 35.8% | 65.9% | 93.0% | 99.7% | 33.6% | 66.4% | 86.4% | 99.1% |
| Holladay 2 | 40.5% | 66.6% | 92.6% | 99.7% | 43.6% | 68.2% | 92.7% | 100.0% |
| SRK/T | 38.5% | 67.6% | 93.0% | 99.7% | 37.3% | 66.4% | 90.9% | 98.2% |
|
|
|
| 0.01 | 0.41 |
| 0.02 | 0.001 | 0.17 |
| *This | ||||||||
Mean absolute error (MAE) for SN60WF and ZCB00 lenses in short, medium, and long eyes.
|
| |||||||||
|
|
|
| |||||||
| Barrett Universal II | 0.37 | 0.34 | 0.78 | 0.43 | 0.40 | 0.62 | 0.35 | 0.69 | 0.04 |
| Haigis | 0.36 | 0.53 | 0.11 | 0.44 | 0.43 | 0.93 | 0.36 | 0.78 | 0.03 |
| Hoffer-Q | 0.30 | 0.33 | 0.75 | 0.45 | 0.45 | 0.87 | 0.53 | 0.95 | 0.04 |
| Holladay 2 | 0.30 | 0.37 | 0.67 | 0.43 | 0.38 | 0.31 | 0.45 | 0.77 | 0.08 |
| SRK/T | 0.36 | 0.55 | 0.36 | 0.44 | 0.48 | 0.48 | 0.41 | 0.70 | 0.21 |
|
| 0.48 | 0.13 | 0.3 | 0.005 |
| 0.04 | |||
Percentage of eyes within 0.5 D of the predicted refraction for SN60WF and ZCB00 lenses for short, medium, and long eyes.
|
| |||||||||
|
| |||||||||
|
|
|
| |||||||
| Barrett Universal II | 70.0% | 85.7% | 0.001 | 69.6% | 68.8% | 0.87 | 81.8% | 42.9% |
|
| Haigis | 70.0% | 57.1% | 0.05 | 65.6% | 66.7% | 0.88 | 77.3% | 42.9% |
|
| Hoffer-Q | 83.3% | 85.7% | 0.55 | 64.4% | 67.7% | 0.55 | 59.1% | 28.6% |
|
| Holladay 2 | 76.7% | 71.4% | 0.33 | 66.0% | 70.8% | 0.44 | 59.1% | 28.6% |
|
| SRK/T | 73.3% | 57.1% | 0.01 | 66.4% | 68.8% | 0.65 | 72.7% | 42.9% |
|
| P-value* | 0.02 | 0.16 |
| 0.04 | 0.004 | 0.41 | |||